Effect of dynamic characteristics of building envelope on thermal-energy performance in winter conditions: In field experiment

被引:55
|
作者
Pisello, Anna Laura [1 ]
Cotana, Franco [1 ]
Nicolini, Andrea [1 ]
Buratti, Cinzia [1 ]
机构
[1] Univ Perugia, Dept Engn, I-06125 Perugia, Italy
关键词
Building continuous monitoring; Energy efficiency in buildings; Indoor thermal behavior; Building envelope; Building thermal-energy performance; In-field envelope conductance and transmittance measurement; Dynamic methods for building thermal-energy assessment; COOL ROOFS; IMPACT; IDENTIFICATION; MODEL;
D O I
10.1016/j.enbuild.2014.05.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research about building strategies for energy saving is taking a growing interest worldwide. New solutions for building envelopes require increasingly sophisticated investigation to analyze the thermal-energy in-field dynamic response of constructions. Moreover, in-lab experiments are difficultly able to represent real environment boundary conditions. In this paper, effect of dynamic properties of building opaque envelope is investigated in winter conditions through an extensive continuous monitoring campaign of a dedicated experimental field. The field consists of: two full-scale buildings, an outdoor weather station, and two indoor microclimate stations. The two buildings were designed with the same stationary envelope characteristics, but different envelope technologies, materials and, therefore, different dynamic properties. Nevertheless, following Italian regulations about building energy performance in winter, they should behave the same. With the purpose to verify this hypothesis, a continuous long-term comparative monitoring is developed. The results only partly confirm that simplified hypothesis. In fact, in winter, while the two buildings exhibit equivalent long-term energy behavior, a weak difference is registered in terms of air temperature in free-floating, transient, and operative HVAC systems' regime. Additionally, non-negligible discrepancies are registered in terms of mean radiant temperature, indoor humidity and internal-external envelope surface temperature, given the different transpiration rate of the two envelope systems and different solar reflectance values of the roofs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 230
页数:13
相关论文
共 50 条
  • [41] The effect of water spray systems on thermal and solar performance of an ETFE panel for building envelope
    Mainini, Andrea Giovanni
    Speroni, Alberto
    Zani, Andrea
    Poli, Tiziana
    TENSINET - COST TU1303 INTERNATIONAL SYMPOSIUM 2016 - NOVEL STRUCTURAL SKINS - IMPROVING SUSTAINABILITY AND EFFICIENCY THROUGH NEW STRUCTURAL TEXTILE MATERIALS AND DESIGNS, 2016, 155 : 352 - 360
  • [42] Dynamic effect of balcony thermal bridges on the energy performance of a high-rise residential building in Canada
    Baba, Fuad
    Ge, Hua
    ENERGY AND BUILDINGS, 2016, 116 : 78 - 88
  • [43] Differentiating responses of weather files and local climate change to explain variations in building thermal-energy performance simulations
    Pyrgou, Andri
    Castaldo, Veronica Lucia
    Pisello, Anna Laura
    Cotana, Franco
    Santamouris, Mattheos
    SOLAR ENERGY, 2017, 153 : 224 - 237
  • [44] Comprehensive building envelope optimization: Improving energy, daylight, and thermal comfort performance of the dwelling unit
    Nasrollahzadeh, Nasrollah
    JOURNAL OF BUILDING ENGINEERING, 2021, 44
  • [45] A comprehensive review of the thermal performance in energy efficient building envelope incorporated with phase change materials
    Tripathi, Bhartendu Mani
    Shukla, Shailendra Kumar
    JOURNAL OF ENERGY STORAGE, 2024, 79
  • [46] Optimization for energy efficiency of underground building envelope thermal performance in different climate zones of China
    Shi, Luyang
    Liu, Jing
    Zhang, Huibo
    INTERNATIONAL CONFERENCE ON ADVANCES IN ENERGY SYSTEMS AND ENVIRONMENTAL ENGINEERING (ASEE17), 2017, 22
  • [47] Energy savings for a junior high school classroom that actively uses daylighting and sensitivity study on the effect of the building envelope thermal performance
    Nur, Yuniar Affa
    Yoon, Gyuyoung
    Sato, Takahiro
    JAPAN ARCHITECTURAL REVIEW, 2022, 5 (04) : 609 - 620
  • [48] Dynamic modeling and performance evaluation of building envelope enhanced with phase change material under Danish conditions
    Hagenau, Morten
    Jradi, Muhyiddine
    JOURNAL OF ENERGY STORAGE, 2020, 30
  • [49] Dynamic analysis of daylight factor, thermal comfort and energy performance under clear sky conditions for building: An experimental validation
    Ahmad A.
    Prakash O.
    Kumar A.
    Mozammil Hasnain S.M.
    Verma P.
    Zare A.
    Dwivedi G.
    Pandey A.
    Materials Science for Energy Technologies, 2022, 5 : 52 - 65
  • [50] Experimental study of the thermal-energy performance of an insulated vegetal facade under summer conditions in a continental mediterranean climate
    Olivieri, F.
    Olivieri, L.
    Neila, J.
    BUILDING AND ENVIRONMENT, 2014, 77 : 61 - 76