Effect of dynamic characteristics of building envelope on thermal-energy performance in winter conditions: In field experiment

被引:55
|
作者
Pisello, Anna Laura [1 ]
Cotana, Franco [1 ]
Nicolini, Andrea [1 ]
Buratti, Cinzia [1 ]
机构
[1] Univ Perugia, Dept Engn, I-06125 Perugia, Italy
关键词
Building continuous monitoring; Energy efficiency in buildings; Indoor thermal behavior; Building envelope; Building thermal-energy performance; In-field envelope conductance and transmittance measurement; Dynamic methods for building thermal-energy assessment; COOL ROOFS; IMPACT; IDENTIFICATION; MODEL;
D O I
10.1016/j.enbuild.2014.05.017
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Research about building strategies for energy saving is taking a growing interest worldwide. New solutions for building envelopes require increasingly sophisticated investigation to analyze the thermal-energy in-field dynamic response of constructions. Moreover, in-lab experiments are difficultly able to represent real environment boundary conditions. In this paper, effect of dynamic properties of building opaque envelope is investigated in winter conditions through an extensive continuous monitoring campaign of a dedicated experimental field. The field consists of: two full-scale buildings, an outdoor weather station, and two indoor microclimate stations. The two buildings were designed with the same stationary envelope characteristics, but different envelope technologies, materials and, therefore, different dynamic properties. Nevertheless, following Italian regulations about building energy performance in winter, they should behave the same. With the purpose to verify this hypothesis, a continuous long-term comparative monitoring is developed. The results only partly confirm that simplified hypothesis. In fact, in winter, while the two buildings exhibit equivalent long-term energy behavior, a weak difference is registered in terms of air temperature in free-floating, transient, and operative HVAC systems' regime. Additionally, non-negligible discrepancies are registered in terms of mean radiant temperature, indoor humidity and internal-external envelope surface temperature, given the different transpiration rate of the two envelope systems and different solar reflectance values of the roofs. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:218 / 230
页数:13
相关论文
共 50 条
  • [31] Energy and thermal comfort management in a kindergarten school building in the South of Portugal in Winter conditions
    Conceicao, Eusebio Z. E.
    Lopes, Margarida C.
    Lucio, M. Manuela J. R.
    NEW ASPECTS OF ENERGY, ENVIRONMENT, ECOSYSTEMS AND SUSTAINABLE DEVELOPMENT, PT 1, 2008, : 90 - +
  • [32] Dynamic thermal performance and energy-saving potential analysis of a modular pipe-embedded building envelope integrated with thermal diffusive materials
    Yang Yang
    Sarula Chen
    Building Simulation, 2023, 16 : 2285 - 2305
  • [33] Dynamic thermal performance and energy-saving potential analysis of a modular pipe-embedded building envelope integrated with thermal diffusive materials
    Yang, Yang
    Chen, Sarula
    BUILDING SIMULATION, 2023, 16 (12) : 2285 - 2305
  • [34] Analysing the Effect of Substrate Properties on Building Envelope Thermal Performance in Various Climates
    Zingre, Kishor T.
    Kumar, D. E. V. S. Kiran
    Wan, Man Pun
    ENERGIES, 2020, 13 (19)
  • [35] Evaluation on energy and thermal performance for office building envelope in different climate zones of China
    Yu, Jinghua
    Tian, Liwei
    Xu, Xinhua
    Wang, Jinbo
    ENERGY AND BUILDINGS, 2015, 86 : 626 - 639
  • [36] Thermal performance of the building envelope integrated with phase change material for thermal energy storage: an updated review
    Rathore, Pushpendra Kumar Singh
    Gupta, Naveen Kumar
    Yadav, Devanand
    Shukla, Shailendra Kumar
    Kaul, Sanjay
    SUSTAINABLE CITIES AND SOCIETY, 2022, 79
  • [37] PREDICTION AND ANALYSIS OF A FIELD EXPERIMENT ON A MULTILAYERED AQUIFER THERMAL-ENERGY STORAGE-SYSTEM WITH STRONG BUOYANCY FLOW
    BUSCHECK, TA
    DOUGHTY, C
    TSANG, CF
    WATER RESOURCES RESEARCH, 1983, 19 (05) : 1307 - 1315
  • [38] Experimental analysis of wall surface colour impacts on building thermal performance in winter conditions
    Liao, Qingxia
    Qiao, Qijin
    He, Lei
    INTERNATIONAL JOURNAL OF LOW-CARBON TECHNOLOGIES, 2025, 20 : 745 - 754
  • [39] Development and application of future design weather data for evaluating the building thermal-energy performance in subtropical Hong Kong
    Liu, Sheng
    Kwok, Yu Ting
    Lau, Kevin Ka-Lun
    Tong, Hong Wai
    Chan, Pak Wai
    Edward, N. G.
    ENERGY AND BUILDINGS, 2020, 209
  • [40] THERMAL-ENERGY STORAGE - DYNAMIC PERFORMANCE-CHARACTERISTICS OF CANS EACH CONTAINING A PHASE-CHANGE MATERIAL, ASSEMBLED AS A PACKED-BED
    GONCALVES, LCC
    PROBERT, SD
    APPLIED ENERGY, 1993, 45 (02) : 117 - 155