Performance of the comet assay in a high-throughput version

被引:29
|
作者
Stang, A. [1 ]
Witte, I. [1 ]
机构
[1] Carl VonOssietzky Univ Oldenburg, IBU, D-26111 Oldenburg, Germany
关键词
Comet assay; High throughput; MCP; Multi-chamber plate; Adherent cells; IN-VITRO; GENETIC TOXICOLOGY; AUTOMATIC-ANALYSIS; MICRONUCLEUS TEST; ELECTROPHORESIS; DISCRIMINATE; FIBROBLASTS; GUIDELINES; SLIDES; CELLS;
D O I
10.1016/j.mrgentox.2009.01.007
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
The high-throughput comet assay was developed to reduce the processing time and to increase sample-throughput of the assay as described by Tice et al. (RR. Tice. E. Agurell, D. Anderson, B. Burlinson, A. Hartmann, H. Kobayashi, Y. Miyamae, E. Rojas. JC. Ryu, YF. Sasaki. Single cell gel/comet assay: guidelines for in vitro and in vivo genetic toxicology testing, Environ. Mol. Mutagen.35 (2000) 206-221). This high-throughput version allows for the processing of up to 400 samples per day. The basis of the new assay is a 96-well plate (multichamber plate. MCP) suitable for electrophoresis. After exposure of the cells to genotoxic agents, the walls of the MCP are separated from the bottom plate. All 96 samples together then go through lysis, alkaline unwinding, electrophoresis, neutralization, and staining. In this Study, the first concentration-dependent results obtained with the high-through put version are shown and a comparison is made with the standard version of the comet assay using five representative chemicals with different genotoxic properties. These genotoxic chemicals are methyl methanesulfonate (MMS) and ethylnitrosourea. which form small alkylation adducts, 4-nitroquinoline-1-oxide for bulky adducts, cisplatin for DNA cross-links, and H2O2 for direct DNA breakage. For medium and high effective concentrations a standard deviation of 3-20% for three replicates(25 cornets per sample)was determined. A comparison of the standard assay with the high-throughput version revealed similar results for MMS and H2O2. The integrated viability assay (FDA assay), which was performed after chemical treatment and before detachment of the bottom from the walls of the MCP. did not influence the outcome of the comet formation. In Conclusion. the high-throughput version of the comet assay facilitates the determination of genotoxicity in cases where large numbers of samples have to be measured, Such as during testing of industrial chemicals, biomonitoring of enviromental samples, and early screening of drug candidates for genotoxicity/photogenotoxicity. For Such applications the cost- and time-saving of the high-throughput method provides substantial advantages over the standard comet assay. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 50 条
  • [41] Multiplexing a High-Throughput Liability Assay to Leverage Efficiencies
    Herbst, John
    Anthony, Monique
    Stewart, Jeremy
    Connors, David
    Chen, Taosheng
    Banks, Martyn
    Petrillo, Edward W.
    Agler, Michele
    ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2009, 7 (03) : 294 - 303
  • [42] A high-throughput sphingomyelinase assay using natural substrate
    Miao Xu
    Ke Liu
    Noel Southall
    Juan J. Marugan
    Alan T. Remaley
    Wei Zheng
    Analytical and Bioanalytical Chemistry, 2012, 404 : 407 - 414
  • [43] A high-throughput sphingomyelinase assay using natural substrate
    Xu, Miao
    Liu, Ke
    Southall, Noel
    Marugan, Juan J.
    Remaley, Alan T.
    Zheng, Wei
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (02) : 407 - 414
  • [45] A high-throughput assay for quantitative measurement of PCR errors
    Shagin, Dmitriy A.
    Shagina, Irina A.
    Zaretsky, Andrew R.
    Barsova, Ekaterina V.
    Kelmanson, Ilya V.
    Lukyanov, Sergey
    Chudakov, Dmitriy M.
    Shugay, Mikhail
    SCIENTIFIC REPORTS, 2017, 7
  • [46] A high-throughput screening assay of ascorbate in brain samples
    Belikova, Natalia A.
    Glumac, Ashley L.
    Kapralova, Valentyna
    Cheikhi, Amin
    Tyurina, Yulia Y.
    Vagni, Vincent A.
    Kochanek, Patrick M.
    Kagan, Valerian E.
    Bayir, Huelya
    JOURNAL OF NEUROSCIENCE METHODS, 2011, 201 (01) : 185 - 190
  • [47] High-throughput screening assay for biological hydrogen production
    Schrader, Paul S.
    Burrows, Elizabeth H.
    Ely, Roger L.
    ANALYTICAL CHEMISTRY, 2008, 80 (11) : 4014 - 4019
  • [48] A high-throughput chemically induced inflammation assay in zebrafish
    d'Alencon, Claudia A.
    Pena, Oscar A.
    Wittmann, Christine
    Gallardo, Viviana E.
    Jones, Rebecca A.
    Loosli, Felix
    Liebel, Urban
    Grabher, Clemens
    Allende, Miguel L.
    BMC BIOLOGY, 2010, 8
  • [49] A high-throughput biliverdin assay using infrared fluorescence
    Berlec, Ales
    Strukelj, Borut
    JOURNAL OF VETERINARY DIAGNOSTIC INVESTIGATION, 2014, 26 (04) : 521 - 526
  • [50] A high-throughput respirometric assay for mitochondrial biogenesis and toxicity
    Beeson, Craig C.
    Beeson, Gyda C.
    Schnellmann, Rick G.
    ANALYTICAL BIOCHEMISTRY, 2010, 404 (01) : 75 - 81