The high-throughput comet assay was developed to reduce the processing time and to increase sample-throughput of the assay as described by Tice et al. (RR. Tice. E. Agurell, D. Anderson, B. Burlinson, A. Hartmann, H. Kobayashi, Y. Miyamae, E. Rojas. JC. Ryu, YF. Sasaki. Single cell gel/comet assay: guidelines for in vitro and in vivo genetic toxicology testing, Environ. Mol. Mutagen.35 (2000) 206-221). This high-throughput version allows for the processing of up to 400 samples per day. The basis of the new assay is a 96-well plate (multichamber plate. MCP) suitable for electrophoresis. After exposure of the cells to genotoxic agents, the walls of the MCP are separated from the bottom plate. All 96 samples together then go through lysis, alkaline unwinding, electrophoresis, neutralization, and staining. In this Study, the first concentration-dependent results obtained with the high-through put version are shown and a comparison is made with the standard version of the comet assay using five representative chemicals with different genotoxic properties. These genotoxic chemicals are methyl methanesulfonate (MMS) and ethylnitrosourea. which form small alkylation adducts, 4-nitroquinoline-1-oxide for bulky adducts, cisplatin for DNA cross-links, and H2O2 for direct DNA breakage. For medium and high effective concentrations a standard deviation of 3-20% for three replicates(25 cornets per sample)was determined. A comparison of the standard assay with the high-throughput version revealed similar results for MMS and H2O2. The integrated viability assay (FDA assay), which was performed after chemical treatment and before detachment of the bottom from the walls of the MCP. did not influence the outcome of the comet formation. In Conclusion. the high-throughput version of the comet assay facilitates the determination of genotoxicity in cases where large numbers of samples have to be measured, Such as during testing of industrial chemicals, biomonitoring of enviromental samples, and early screening of drug candidates for genotoxicity/photogenotoxicity. For Such applications the cost- and time-saving of the high-throughput method provides substantial advantages over the standard comet assay. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:5 / 10
页数:6
相关论文
共 50 条
  • [31] High-throughput screening: advances in assay technologies
    Sittampalam, GS
    Kahl, SD
    Janzen, WP
    CURRENT OPINION IN CHEMICAL BIOLOGY, 1997, 1 (03) : 384 - 391
  • [32] High-throughput screening - Free your assay
    Kirkpatrick, P
    NATURE REVIEWS DRUG DISCOVERY, 2004, 3 (07) : 553 - 553
  • [33] High-throughput Saccharification Assay for Lignocellulosic Materials
    Gomez, Leonardo D.
    Whitehead, Caragh
    Roberts, Philip
    McQueen-Mason, Simon J.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2011, (53):
  • [34] The Development and Validation of EpiComet-Chip, a Modified High-Throughput Comet Assay for the Assessment of DNA Methylation Status
    Townsend, Todd A.
    Parrish, Marcus C.
    Engelward, Bevin P.
    Manjanatha, Mugimane G.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2017, 58 (07) : 508 - 521
  • [35] Validation of Gelbond® high-throughput alkaline and Fpg-modified comet assay using a linear mixed model
    Perdry, Herve
    Gutzkow, Kristine B.
    Chevalier, Marianne
    Huc, Laurence
    Brunborg, Gunnar
    Boutet-Robinet, Elisa
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2018, 59 (07) : 595 - 602
  • [36] The Development and Validation of EpiComet-Chip, a Modified High-Throughput Comet Assay for the Assessment of DNA Methylation Status.
    Townsend, T. A.
    Parrish, M. C.
    Bishop, M. E.
    Shelton, S. D.
    Engelward, B. P.
    Manjanatha, M. G.
    ENVIRONMENTAL AND MOLECULAR MUTAGENESIS, 2016, 57 : S46 - S46
  • [37] Integrating text mining into high-throughput assay analysis
    Cohen, K. Bretonnel
    BMC BIOINFORMATICS, 2010, 11
  • [38] High-throughput sequential injection assay method for chlorpromazine
    Naheid, S.A., 1600, Maik Nauka Publishing / Springer SBM (68):
  • [39] Differential assay for high-throughput screening of antibacterial compounds
    Falk, Shaun P.
    Ulijasz, Andrew T.
    Weisblum, Bernard
    JOURNAL OF BIOMOLECULAR SCREENING, 2007, 12 (08) : 1102 - 1108
  • [40] Fluorophoric assay for the high-throughput determination of amidase activity
    Henke, E
    Bornscheuer, UT
    ANALYTICAL CHEMISTRY, 2003, 75 (02) : 255 - 260