摘要
Nowadays the main thermoluminescence dosimetry systems for measurements of individual and environmental doses are based on thermoluminescent (TLD) detectors. In 2005 at the IFJ PAN a new system of 2-D measurements with specially prepared planar thermoluminescent dosemeter was built. The system contains TL detector (special developed planar TL foil with different size or normal pellets - 0.9 thickness and 2.4 diameter) and a special TL reader where CCD camera is measuring TL signal. The result from that system is 2-D image of TL lighting. The new system has found a few practical applications. Historically first use of TL foils was for measurements of dose distribution around anode like X-ray tube. Next use was for check in doses using radiotherapy procedures and finally to distinguish between static and dynamic exposure in individual dosimetry. During last two years TL foils were tested in interventional radiology procedures. In this work the results of different studies on the two-dimensional technique, both using TL pellets (to distinguish static or dynamic exposure) as well as the TL planar foils will be presented.
引用
收藏
页码:180 / 180
页数:1
相关论文
共 50 条
  • [11] THERMOLUMINESCENT DOSIMETRY FOR FAST-NEUTRON BEAMS USING CAF2-MN
    BLUM, E
    BEWLEY, DK
    HEATHER, JD
    PHYSICS IN MEDICINE AND BIOLOGY, 1973, 18 (02): : 226 - 234
  • [12] 2-D or not 2-D?
    Rao, SS
    FORBES, 1999, 164 (12): : 234 - 234
  • [13] Stereotactic radiosurgery dosimetry using thermoluminescent dosimeters and radiochromic films
    Avila-Rodríguez, MA
    Rodríguez-Villafuerte, M
    Perches, RD
    MEDICAL PHYSICS, 2000, 538 : 213 - 218
  • [14] NEUTRON DOSIMETRY USING ACTIVATION OF THERMOLUMINESCENT CASO4
    AZORIN, J
    GUTIERREZ, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 227 (01): : 150 - 153
  • [15] Coloured glasses for high dose dosimetry using the thermoluminescent technique
    Caldas, LVE
    Teixeira, MI
    RADIATION PROTECTION DOSIMETRY, 2004, 111 (01) : 13 - 15
  • [16] First results of a scintillating GEM detector for 2-d Dosimetry in an α beam
    Seravalli, Enrica
    Hendrikse, Jeffrey
    Huizenga, Jan
    Kreuger, Rob
    Schippers, J. Marco
    Simon, Andrea
    van Eijk, Carel W. E.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2007, 54 (04) : 1271 - 1278
  • [17] 2-D GEM-BASED TEPC FOR NEUTRON PROTECTION DOSIMETRY
    Seydaliev, Marat
    Dubeau, Jacques
    Witharana, Sampath Sanjeewa Hakmana
    CNL NUCLEAR REVIEW, 2018, 7 (01) : 24 - 32
  • [18] Realization methods of singular 2-D systems
    Hu, Zhihua
    Tang, Wansheng
    Li, Guangquan
    Liu, Zeyi
    1996, (11):
  • [19] Implementation of 2-D biorthogonal wavelet transform using 2-D APDF
    Fu, Qiming
    Zhou, Xiao
    Wang, Chengyou
    Jiang, Baochen
    International Journal of Signal Processing, Image Processing and Pattern Recognition, 2015, 8 (05) : 55 - 74
  • [20] Gallbladder Segmentation in 2-D Ultrasound Images Using Deformable Contour Methods
    Ciecholewski, Marcin
    MODELING DECISIONS FOR ARTIFICIAL INTELLIGENCE (MDAI), 2010, 6408 : 163 - 174