Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples

被引:8
|
作者
del Carmen Salvatierra-Stamp, Vilma [1 ]
Ceballos-Magana, Silvia G. [2 ]
Susana Pano-Farias, Norma [3 ]
Belisario Leyva-Morales, Jose [4 ]
Pineda-Urbina, Kayim [1 ]
Muniz-Valencia, Roberto [1 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Carretera Colima Coquimatlan Km 9, Colima 28400, Mexico
[2] Univ Colima, Fac Ciencias, C Bernal Diaz del Castillo 340, Colima 28045, Mexico
[3] CIDAM AC, Ctr Innovac & Desarrollo Agroalimentario Michoaca, Antigua Carretera Patzcuaro Km 8, Morelia 58341, Michoacan, Mexico
[4] Univ Autonoma Occidente, Dept Salud, Unidad Guasave, Av Univ S-N, Guasave 81044, Sinaloa, Mexico
关键词
Multiclass emerging contaminants; Hollow fiber liquid-phase microextraction; Supercritical fluid chromatography; Water samples; EXTRACTION; EFFICIENCY;
D O I
10.1007/s00216-021-03202-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The hollow fiber liquid-phase microextraction allows highly selective concentration of organic compounds that are at trace levels. The determination of those analytes through the supercritical fluid chromatography usage is associated with many analytical benefits, which are significantly increased when it is coupled to a mass spectrometry detector, thus providing an extremely sensitive analytical technique with minimal consumption of organic solvents. On account of this, a hollow fiber liquid-phase microextraction technique in two-phase mode combined with supercritical fluid chromatography coupled to mass spectrometry was developed for quantifying 19 multiclass emerging contaminants in water samples in a total chromatographic time of 5.5 min. The analytical method used 40 mu L of 1-octanol placed in the porous-walled polypropylene fiber as the acceptor phase, and 1 L of water sample was the donor phase. After extraction and quantification techniques were optimized in detail, a good determination coefficient (r(2) > 0.9905) in the range of 0.1 to 100 mu g L-1, for most of the analytes, and an enrichment factor in the range of 7 to 28,985 were obtained. The recovery percentage (%R) and intraday precision (%RSD) were in the range of 80.80-123.40%, and from 0.48 to 16.89%, respectively. Limit of detection and quantification ranged from 1.90 to 35.66 ng L-1, and from 3.41 to 62.11 ng L-1, respectively. Finally, the developed method was successfully used for the determination of the 19 multiclass emerging contaminants in superficial and wastewater samples.
引用
收藏
页码:2467 / 2479
页数:13
相关论文
共 50 条
  • [21] Determination of tetrandrine and fangchinoline in plasma samples using hollow fiber liquid-phase microextraction combined with high-performance liquid chromatography
    Yang, Cailing
    Guo, Linyuan
    Liu, Xiaoyan
    Zhang, Haixia
    Liu, Mancang
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1164 (1-2) : 56 - 64
  • [22] HOLLOW FIBER LIQUID-PHASE MICROEXTRACTION COMBINED WITH GAS CHROMATOGRAPHY-MASS SPECTROMETRY FOR DETERMINATION OF ROOT EXUDATIVE POTENTIAL ALLELOCHEMICALS IN CAPSICUM ANNUUM(CHILI)
    Sun, Haiyan
    Wang, Yan
    ANALYTICAL LETTERS, 2012, 45 (12) : 1566 - 1580
  • [23] Determination of Trace Bisphenol A in Water Using Three-phase Hollow Fiber Liquid-phase Microextraction Coupled with High Performance Liquid Chromatography
    Tan Xiao-Wang
    Song Yan-Xi
    Wei Rui-Ping
    Yi Gu-Yang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (09) : 1409 - 1414
  • [24] Determination of Polycyclic Aromatic Hydrocarbons in Fresh Milk by Hollow Fiber Liquid-Phase Microextraction-Gas Chromatography Mass Spectrometry
    Sanagi, Mohd Marsin
    Loh, Saw Hong
    Ibrahim, Wan Aini Wan
    Hasan, Mohamed Noor
    Enein, Hassan Y. Aboul
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2013, 51 (02) : 112 - 116
  • [25] Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography-mass spectrometry
    dos Santos, Marcelo Filonzi
    Ferri, Caio Caleiras
    Seulin, Saskia Carolina
    Leyton, Vilma
    Goncalves Pasqualucci, Carlos Augusto
    Munoz, Daniel Romero
    Yonamine, Mauricio
    FORENSIC TOXICOLOGY, 2014, 32 (02) : 214 - 224
  • [26] Miniaturized hollow fiber assisted liquid-phase microextraction and gas chromatography-mass spectrometry for the measurement of progesterone in human serum
    Kawaguchi, Migaku
    Takatsu, Akiko
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (03): : 343 - 346
  • [27] Simultaneous derivatization and extraction of nitrophenols in soil and rain samples using modified hollow-fiber liquid-phase microextraction followed by gas chromatography–mass spectrometry
    Hamid Reza Sobhi
    Ali Esrafili
    Hadi Farahani
    Mitra Gholami
    Mohammad Mehdi Baneshi
    Environmental Monitoring and Assessment, 2013, 185 : 9055 - 9065
  • [28] Determination of Benzyl Chloride in Water by Hollow Fiber Liquid Phase Microextraction-Gas Chromatography-Mass Spectrometry
    Diao Chun-Peng
    Yuan Jin-Peng
    Li Lei
    Jiang Ting
    Zhao Ru-Song
    Cheng Chuan-Ge
    Liu Re Min
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2008, 36 (11) : 1559 - 1562
  • [29] Determination of ethoprop, diazinon, disulfoton and fenthion using dynamic hollow fiber-protected liquid-phase microextraction coupled with gas chromatography-mass spectrometry
    Chen, Pai-Shan
    Huang, Shang-Da
    TALANTA, 2006, 69 (03) : 669 - 675
  • [30] Hollow fiber liquid-phase microextraction as clean-up step for the determination of organophosphorus pesticides residues in fish tissue by gas chromatography coupled with mass spectrometry
    Sun, Xiaojin
    Zhu, Fang
    Xi, Jiabin
    Lu, Tongbu
    Liu, Hong
    Tong, Yexiang
    Ouyang, Gangfeng
    MARINE POLLUTION BULLETIN, 2011, 63 (5-12) : 102 - 107