Hollow fiber liquid-phase microextraction combined with supercritical fluid chromatography coupled to mass spectrometry for multiclass emerging contaminant quantification in water samples

被引:8
|
作者
del Carmen Salvatierra-Stamp, Vilma [1 ]
Ceballos-Magana, Silvia G. [2 ]
Susana Pano-Farias, Norma [3 ]
Belisario Leyva-Morales, Jose [4 ]
Pineda-Urbina, Kayim [1 ]
Muniz-Valencia, Roberto [1 ]
机构
[1] Univ Colima, Fac Ciencias Quim, Carretera Colima Coquimatlan Km 9, Colima 28400, Mexico
[2] Univ Colima, Fac Ciencias, C Bernal Diaz del Castillo 340, Colima 28045, Mexico
[3] CIDAM AC, Ctr Innovac & Desarrollo Agroalimentario Michoaca, Antigua Carretera Patzcuaro Km 8, Morelia 58341, Michoacan, Mexico
[4] Univ Autonoma Occidente, Dept Salud, Unidad Guasave, Av Univ S-N, Guasave 81044, Sinaloa, Mexico
关键词
Multiclass emerging contaminants; Hollow fiber liquid-phase microextraction; Supercritical fluid chromatography; Water samples; EXTRACTION; EFFICIENCY;
D O I
10.1007/s00216-021-03202-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The hollow fiber liquid-phase microextraction allows highly selective concentration of organic compounds that are at trace levels. The determination of those analytes through the supercritical fluid chromatography usage is associated with many analytical benefits, which are significantly increased when it is coupled to a mass spectrometry detector, thus providing an extremely sensitive analytical technique with minimal consumption of organic solvents. On account of this, a hollow fiber liquid-phase microextraction technique in two-phase mode combined with supercritical fluid chromatography coupled to mass spectrometry was developed for quantifying 19 multiclass emerging contaminants in water samples in a total chromatographic time of 5.5 min. The analytical method used 40 mu L of 1-octanol placed in the porous-walled polypropylene fiber as the acceptor phase, and 1 L of water sample was the donor phase. After extraction and quantification techniques were optimized in detail, a good determination coefficient (r(2) > 0.9905) in the range of 0.1 to 100 mu g L-1, for most of the analytes, and an enrichment factor in the range of 7 to 28,985 were obtained. The recovery percentage (%R) and intraday precision (%RSD) were in the range of 80.80-123.40%, and from 0.48 to 16.89%, respectively. Limit of detection and quantification ranged from 1.90 to 35.66 ng L-1, and from 3.41 to 62.11 ng L-1, respectively. Finally, the developed method was successfully used for the determination of the 19 multiclass emerging contaminants in superficial and wastewater samples.
引用
收藏
页码:2467 / 2479
页数:13
相关论文
共 50 条
  • [11] Automated polyvinylidene difluoride hollow fiber liquid-phase microextraction of flunitrazepam in plasma and urine samples for gas chromatography/tandem mass spectrometry
    Cui, Shufen
    Tan, Shuo
    Ouyang, Gangfeng
    Pawliszyn, Janusz
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (12) : 2241 - 2247
  • [12] Determination of Pyrethroids in Soil by Hollow Fiber-based Liquid-Phase Microextraction and Chromatography-Mass Spectrometry
    Shao Yan
    Zhang Li-Jun
    Zhang Zhan-En
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (11) : 1753 - 1757
  • [13] Determination of organic micropollutants in rainwater using hollow fiber membrane/liquid-phase microextraction combined with gas chromatography-mass spectrometry
    Basheer, C
    Balasubramanian, R
    Lee, HK
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1016 (01) : 11 - 20
  • [14] Automated hollow-fiber liquid-phase microextraction coupled with liquid chromatography/tandem mass spectrometry for the analysis of aflatoxin M1 in milk
    Huang, Siming
    Hu, Du
    Wang, Ying
    Zhu, Fang
    Jiang, Ruifen
    Ouyang, Gangfeng
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1416 : 137 - 140
  • [15] Nonequilibrium hollow-fiber liquid-phase microextraction with in situ derivatization for the measurement of triclosan in aqueous samples by gas chromatography-mass spectrometry
    Zhao, Ru-Song
    Yuan, Jin-Peng
    Li, Hai-Fang
    Wang, Xu
    Jiang, Ting
    Lin, Jin-Ming
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 387 (08) : 2911 - 2915
  • [16] Determination of total thyroxine in human serum by hollow fiber liquid-phase microextraction and liquid chromatography-tandem mass spectrometry
    Yong, Sharon
    Chen, Yizhao
    Lee, Tong Kooi
    Lee, Hian Kee
    TALANTA, 2014, 126 : 163 - 169
  • [17] Bioanalysis of pharmaceuticals using liquid-phase microextraction combined with liquid chromatography-mass spectrometry
    Hansen, Frederik
    Oiestad, Elisabeth Leere
    Pedersen-Bjergaard, Stig
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 189
  • [18] Determination of antidepressants in whole blood using hollow-fiber liquid-phase microextraction and gas chromatography–mass spectrometry
    Marcelo Filonzi dos Santos
    Caio Caleiras Ferri
    Saskia Carolina Seulin
    Vilma Leyton
    Carlos Augusto Gonçalves Pasqualucci
    Daniel Romero Muñoz
    Mauricio Yonamine
    Forensic Toxicology, 2014, 32 : 214 - 224
  • [19] Liquid-phase microextraction combined with liquid chromatography-mass spectrometry. Extraction from small volumes of biological samples
    Halvorsen, TG
    Pedersen-Bjergaard, S
    Reubsaet, JLE
    Rasmussen, KE
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (17) : 1520 - 1526
  • [20] Hollow fiber based liquid-phase microextraction for the determination of mercury traces in water samples by electrothermal atomic absorption spectrometry
    Lopez-Garcia, Ignacio
    Rivas, Ricardo E.
    Hernandez-Cordoba, Manuel
    ANALYTICA CHIMICA ACTA, 2012, 743 : 69 - 74