Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

被引:215
|
作者
Hong, Myeong-Ki
Mintz, Gary S.
Lee, Cheol Whan
Park, Duk-Woo
Choi, Bong-Ryong
Park, Kyoung-Ha
Kim, Young-Hak
Cheong, Sang-Sig
Song, Jae-Kwan
Kim, Jae-Joong
Park, Seong-Wook
Park, Seung-Jung
机构
[1] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Seoul 138736, South Korea
[2] Cardiovasc Res Fdn, New York, NY USA
[3] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Kangnung, South Korea
关键词
ultrasonics; stent; coronary disease;
D O I
10.1093/eurheartj/ehi882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. Methods and results SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR) = 0.586, 95% confidence interval (Cl) 0.387-0.888, P = 0.012] and IVUS-measured stent length (OR = 1.029, 95% Cl 1.002-1.056, P = 0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm(2) and 40 mm, respectively. Lesions with final minimum stent area < 5.5 mm(2) and stent length > 40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P < 0.001 compared with other groups. Conclusion Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area < 5.5 mm(2) and stent length > 40 mm.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 50 条
  • [41] Serial angiographic findings and prognosis of stent fracture site without early restenosis after sirolimus-eluting stent implantation
    Ino, Yasushi
    Toyoda, Yasuaki
    Tanaka, Atsushi
    Ishii, Shuuta
    Kusuyama, Yoshio
    Kubo, Takashi
    Takarada, Shigeho
    Kitabata, Hironori
    Tanimoto, Takashi
    Hirata, Kumiko
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    AMERICAN HEART JOURNAL, 2010, 160 (04) : 775.e1 - 775.e9
  • [42] Intravascular ultrasound evaluation after sirolimus eluting stent implantation for de novo and in-stent restenosis lesions
    Degertekin, M
    Lemos, PA
    Lee, CH
    Tanabe, K
    Sousa, JE
    Abizaid, A
    Regar, E
    Sianos, G
    van der Giessen, WJ
    de Feyter, PJ
    Wuelfert, E
    Popma, JJ
    Serruys, PW
    EUROPEAN HEART JOURNAL, 2004, 25 (01) : 32 - 38
  • [43] Intravascular ultrasound assessment of lesions with target vessel failure after sirolimus-eluting stent implantation
    Takebayashi, H
    Kobayashi, Y
    Mintz, GS
    Carlier, SG
    Fujii, K
    Yasuda, T
    Moussa, I
    Mehran, R
    Dangas, GD
    Collins, MB
    Kreps, E
    Lansky, AJ
    Stone, GW
    Leon, MB
    Moses, JW
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (04): : 498 - 502
  • [44] Sirolimus-eluting stents abolish neointimal hyperplasia in patients with in-stent restenosis: Late angiographic and intravascular ultrasound results
    Serruys, PW
    Abizaid, A
    Foley, D
    Abizaid, A
    de Feyter, P
    Popma, J
    Degertakin, M
    Staico, R
    Pinto, L
    Wuelfert, E
    Sousa, A
    Sousa, JE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 37A - 37A
  • [45] Effectiveness of cutting balloon angioplasty and sirolimus-eluting stent implantation for in-stent restenosis under the guidance of intravascular ultrasound.
    Kim, YH
    Lee, BK
    Kim, MJ
    Yang, TH
    Lee, SW
    Han, KH
    Lee, CW
    Hong, MK
    Kim, JJ
    Park, SW
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (6A): : 136E - 136E
  • [46] THE IMPACT OF HINGE MOTION ON IN-STENT RESTENOSIS AFTER SIROLIMUS-ELUTING STENT IMPLANTATION
    Ino, Yasushi
    Kitabata, Hironori
    Tanaka, Atsushi
    Kubo, Takashi
    Takarada, Shigeho
    Tanimoto, Takashi
    Komukai, Kennichi
    Ishibashi, Kouhei
    Ookouchi, Keishi
    Kuroi, Akio
    Shimokado, Aiko
    Hirata, Kumiko
    MIzukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10)
  • [47] Effectiveness of sirolimus-eluting stent implantation for recurrent in-stent restenosis after brachytherapy
    Saia, F
    Lemos, PA
    Sianos, G
    Degertekin, M
    Lee, CH
    Arampatzis, CA
    Hoye, A
    Tanabe, K
    Regar, E
    van der Giessen, WJ
    Smits, PC
    de Feyter, P
    Ligthart, J
    van Domburg, RT
    Serruys, PW
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (02): : 200 - 203
  • [48] Impact of Hinge Motion on In-Stent Restenosis After Sirolimus-Eluting Stent Implantation
    Ino, Yasushi
    Kubo, Takashi
    Kitabata, Hironori
    Shimamura, Kunihiro
    Shiono, Yasutsugu
    Orii, Makoto
    Okochi, Keishi
    Sougawa, Hiromichi
    Tanimoto, Takashi
    Komukai, Kenichi
    Ishibashi, Kohei
    Takarada, Shigeho
    Nakanishi, Hiroko
    Tanaka, Atsushi
    Kimura, Keizo
    Hirata, Kumiko
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2011, 75 (08) : 1878 - 1884
  • [49] Impact of Hinge Motion on In-Stent Restenosis after Sirolimus-Eluting Stent Implantation
    Ino, Yasushi
    Kubo, Takashi
    Shimamura, Kunihiro
    Satogami, Keiryou
    Kitabata, Hironori
    Kimura, Keizo
    Hirata, Kumiko
    Komukai, Kenichi
    Tanimoto, Takashi
    Ishibashi, Kohei
    Mizukoshi, Masato
    Imanishi, Toshio
    Akasaka, Takashi
    CIRCULATION, 2010, 122 (21)
  • [50] Stent fracture is one of the leading cause of restenosis after sirolimus-eluting stent implantation
    Lee, Sang-Hee
    Park, Jongsun
    Kim, Ung
    Hong, Geuru
    Shin, Donggu
    Kim, Youngjo
    Shim, Bongsub
    CIRCULATION, 2006, 114 (18) : 394 - 394