Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation

被引:215
|
作者
Hong, Myeong-Ki
Mintz, Gary S.
Lee, Cheol Whan
Park, Duk-Woo
Choi, Bong-Ryong
Park, Kyoung-Ha
Kim, Young-Hak
Cheong, Sang-Sig
Song, Jae-Kwan
Kim, Jae-Joong
Park, Seong-Wook
Park, Seung-Jung
机构
[1] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Seoul 138736, South Korea
[2] Cardiovasc Res Fdn, New York, NY USA
[3] Univ Ulsan, Coll Med, Dept Med, Asan Med Ctr, Kangnung, South Korea
关键词
ultrasonics; stent; coronary disease;
D O I
10.1093/eurheartj/ehi882
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims In many countries, drug-eluting stent implantation is the dominant interventional strategy. We evaluated the clinical, angiographic, procedural, and intravascular ultrasound (IVUS) predictors of angiographic restenosis after sirolimus-eluting stent (SES) implantation. Methods and results SES implantation was successfully performed in 550 patients with 670 native coronary lesions. Six-month follow-up angiography was performed in 449 patients (81.6%) with 543 lesions (81.1%). Clinical, angiographic, procedural, and IVUS predictors of restenosis were determined. Using multivariable logistic regression analysis, the only independent predictors of angiographic restenosis were post-procedural final minimum stent area by IVUS [odds ratio (OR) = 0.586, 95% confidence interval (Cl) 0.387-0.888, P = 0.012] and IVUS-measured stent length (OR = 1.029, 95% Cl 1.002-1.056, P = 0.035). Final minimum stent area by IVUS and IVUS-measured stent length that best separated restenosis from non-restenosis were 5.5 mm(2) and 40 mm, respectively. Lesions with final minimum stent area < 5.5 mm(2) and stent length > 40 mm had the highest rate of angiographic restenosis [17.7% (11/62)], P < 0.001 compared with other groups. Conclusion Independent predictors of angiographic restenosis after SES implantation were post-procedural final minimum stent area by IVUS and IVUS-measured stent length. The angiographic restenosis rate was highest in lesions with stent area < 5.5 mm(2) and stent length > 40 mm.
引用
收藏
页码:1305 / 1310
页数:6
相关论文
共 50 条
  • [1] Intravascular ultrasonic predictors of angiographic restenosis after sirolimus-eluting stent implantation
    Hong, MK
    Lee, CW
    Kim, YH
    Lee, BK
    Kang, DH
    Cheong, SS
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 186H - 186H
  • [2] Intravascular ultrasound predictors and their cut-off values for angiographic restenosis after sirolimus-eluting stent implantation
    Hong, MK
    Lee, CW
    Kim, YH
    Lee, BK
    Park, DW
    Kang, DH
    Cheong, SS
    Song, JK
    Kim, JJ
    Park, SW
    Park, SJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 189A - 189A
  • [3] Angiographic Patterns of Restenosis After Sirolimus-Eluting Stent Implantation
    Kitahara, Hideki
    Kobayashi, Yoshio
    Takebayashi, Hideo
    Nakamura, Yoshitake
    Kuroda, Nakabumi
    Miyazaki, Akira
    Haruta, Seiichi
    Komuro, Issei
    CIRCULATION JOURNAL, 2009, 73 (03) : 508 - 511
  • [4] Predictors of angiographic stent fracture and stent fracture with restenosis after sirolimus-eluting stent (SES) implantation
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Goto, Tsuyoshi
    Yamamoto, Hiroyuki
    Kato, Hanumi
    Fuku, Yasushi
    Hosoki, Shingo
    Tanaka, Hiroyuki
    Yamamoto, Kanjyo
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (10) : B7 - B7
  • [5] Recurrent Restenosis After Reimplantation With Sirolimus-eluting Stent for Restenosis After Sirolimus-eluting Stent Implantation
    Miyamoto, Masakazu
    Kadota, Kazushige
    Mitsudo, Kazuaki
    Gotoh, Tsuyoshi
    Yamamoto, Hiroyuki
    Fujii, Satoki
    Fuku, Yasushi
    Hosogi, Shingo
    Tanaka, Hiroyuki
    Habara, Seiji
    Hasegawa, Daiji
    Imai, Masao
    Ohtsuru, Suguru
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (10) : A10 - A10
  • [6] Prediction of late restenosis after sirolimus-eluting stent implantation using serial quantitative angiographic and intravascular ultrasound analysis
    Funada R.
    Oikawa Y.
    Yajima J.
    Matsuno S.
    Kano H.
    Kirigaya H.
    Nagashima K.
    Kurabayashi M.
    Aizawa T.
    Cardiovascular Intervention and Therapeutics, 2011, 26 (1) : 26 - 32
  • [7] Intravascular ultrasound findings of edge restenosis following long sirolimus-eluting stent implantation
    Hong, Young Joon
    Mintz, Gary S.
    Kim, Sang Wook
    Pichard, Augusto D.
    Satler, Lowell F.
    Waksman, Ron
    Kent, Kenneth M.
    Suddath, William O.
    Weissman, Neil J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (8A): : 95M - 95M
  • [8] Predictors of outcome after sirolimus-eluting stent implantation for complex in-stent restenosis
    Migliorini, A
    Shehu, M
    Carrabba, N
    Giurlani, L
    Valenti, R
    Buonamici, P
    Dovellini, EV
    Parodi, G
    Antoniucci, D
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (08): : 1110 - 1112
  • [9] Effects of cilostazol on angiographic restenosis after coronary sirolimus-eluting stent (SES) implantation
    Kim, SM
    Kim, DK
    Park, YW
    Kim, DI
    Kim, DS
    AMERICAN JOURNAL OF CARDIOLOGY, 2005, 95 (8A): : 43A - 43A
  • [10] Angiographic and ultrasonic patterns of restenosis following sirolimus-eluting stent implantation
    Romero, M
    Medina, A
    de Lazo, JS
    Pan, M
    Delgado, A
    Segura, J
    Pavlovic, DJ
    Ojeda, S
    EUROPEAN HEART JOURNAL, 2004, 25 : 565 - 566