First results from the CMS SiPM-based hadronic endcap calorimeter

被引:4
|
作者
De Guio, Federico [1 ]
机构
[1] Texas Tech Univ, Lubbock, TX 79409 USA
来源
18TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2018) | 2019年 / 1162卷
关键词
D O I
10.1088/1742-6596/1162/1/012009
中图分类号
O412 [相对论、场论]; O572.2 [粒子物理学];
学科分类号
摘要
The CMS hadronic calorimeter employs a plastic-scintillator-based endcap detector. In early 2017, a 20 degrees wedge of the endcap was upgraded with silicon photomultipliers (SiPMs) and readout electronics based on the QIE11 digitizer. Based on the excellent experience with this 20 degrees pilot system in 2017, the entire endcap detector was upgraded with SiPMs in early 2018. We report on the first ever operation of SiPMs in a high-rate collider detector. We compare SiPM performance to that of the previous hybrid photodiode / QIE8-based readout and describe how the factor three improvement in photon-detection efficiency, increased longitudinal segmentation, and improved response stability allow for mitigation of scintillator radiation damage and simplified calibration. We report in situ measurements of radiation-induced SiPM dark current. Overall, we show that the upgraded SiPM-based system brings more than 50% improvement in radiation-induced response degradation.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Results from a new combined test of an electromagnetic liquid argon calorimeter with a hadronic scintillating-tile calorimeter
    Akhmadaliev, S
    Albiol, F
    Amaral, P
    Ambrosini, G
    Amorim, A
    Anderson, K
    Andrieux, ML
    Aubert, B
    Augé, E
    Badaud, F
    Baisin, L
    Barreiro, F
    Battistoni, G
    Bazan, A
    Bazizi, K
    Bee, C
    Belorgey, J
    Belymam, A
    Benchekroun, D
    Berglund, S
    Berset, JC
    Blanchot, G
    Bogush, A
    Bohm, C
    Boldea, V
    Bonivento, W
    Borgeaud, P
    Borisov, O
    Bosman, M
    Bouhemaid, N
    Breton, D
    Brette, P
    Bromberg, C
    Budagov, J
    Burdin, S
    Caloba, L
    Camarena, F
    Camin, DV
    Canton, B
    Caprini, M
    Carvalho, J
    Casado, P
    Cases, R
    Castillo, MV
    Cavalli, D
    Cavalli-Sforza, M
    Cavasinni, V
    Chadelas, R
    Chalifour, M
    Chekhtman, L
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (03): : 461 - 477
  • [22] Construction, Commissioning and First Results of a Highly Granular Hadron Calorimeter with SiPM-on-Tile Read-out
    Chau, Phi
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [23] First physics results from the CMS experiment at the LHC
    Tonelli, G.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2012, 35 (01): : 151 - 161
  • [24] The CALICE tile hadron calorimeter prototype with SiPM read-out: Design, construction and first test beam results
    Sefkow, Felix
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 259 - 263
  • [25] Test Beam Results from the CALICE Tile Hadron Calorimeter Prototype with SiPM Read-Out
    Lutz, Benjamin
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 2683 - 2687
  • [26] Test results from a prototype lead tungstate crystal calorimeter with vacuum phototriode readout for the CMS experiment
    Apollonio, M
    Barber, G
    Bell, K
    Britton, D
    Brooke, J
    Brown, R
    Bourotte, J
    Camanzi, B
    Cockerill, D
    Davies, G
    Devitsin, E
    Gninenko, S
    Golubev, N
    Goussev, Y
    Grafström, P
    Haguenauer, M
    Head, R
    Heath, H
    Hobson, P
    Inyakin, A
    Katchanov, V
    Kirsanov, M
    Lintern, L
    Lodge, A
    Mcleod, E
    Nash, S
    Newbold, D
    Ukhanov, M
    Postoev, V
    Patalakha, D
    Presland, A
    Probert, M
    Seez, C
    Semeniouk, I
    Seliverstov, D
    Smith, B
    Sproston, M
    Tapper, R
    Tchuiko, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 484 (1-3): : 287 - 298
  • [27] INSERT Project: First Results of a MR Compatible Preclinical SPECT Based on SiPM Photodetectors
    Occhipinti, M.
    Busca, P.
    Carminati, M.
    Fiorini, C.
    Montagnani, G. L.
    Nagy, K.
    Legradi, G.
    Bukki, T.
    Nyitrai, Z.
    Papp, Z.
    Nagy, A.
    Kuehne, A.
    Niendorf, T.
    Piemonte, C.
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [28] First results of an ASIC controlled γ-detector based on a SiPM-array and a monolithic LYSO
    Conde, P.
    Gonzalez, A. J.
    Hernandez, L.
    Moliner, L.
    Orero, A.
    Rodriguez, M. J.
    Sanchez, F.
    Soriano, A.
    Vidal, L. F.
    Benlloch, J. M.
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 412 - 414
  • [29] FIRST RESULTS FROM THE 2010 pp RUN AND PERFORMANCE OF THE CMS EXPERIMENT
    Leonidopoulos, Christos
    MODERN PHYSICS LETTERS A, 2011, 26 (15) : 1059 - 1073
  • [30] Results from the First Two Years of Operation of the LHC: the CMS Experiment
    Acosta, Darin
    11TH CONFERENCE ON THE INTERSECTIONS OF PARTICLE AND NUCLEAR PHYSICS (CIPANP 2012), 2013, 1560 : 21 - 28