Influence of Surrounding Structures upon the Aerodynamic and Acoustic Performance of the Outdoor Unit of a Split Air-Conditioner

被引:5
|
作者
Wu Chengjun [1 ]
Liu Jiang [1 ]
Pan Jie [2 ]
机构
[1] Xi An Jiao Tong Univ, Sch Mech Engn, Xian 710049, Peoples R China
[2] Univ Western Australia, Sch Mech & Chem Engn, Crawley, WA 6009, Australia
关键词
DC-inverter split air-conditioner; outdoor unit; surrounding structure; computational fluid dynamics(CFD); computational aerodynamic acoustics(CAA); simulation; improved design; AXIAL-FLOW FAN; BROAD-BAND NOISE; AEROACOUSTIC NOISE; LDV MEASUREMENTS; PROPELLER FAN; PREDICTION; SIMULATION; SOUND; FIELD; SET;
D O I
10.3901/CJME.2014.0515.095
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
DC-inverter split air-conditioner is widely used in Chinese homes as a result of its high-efficiency and energy-saving. Recently, the researches on its outdoor unit have focused on the influence of surrounding structures upon the aerodynamic and acoustic performance, however they are only limited to the influence of a few parameters on the performance, and practical design of the unit requires more detailed parametric analysis. Three-dimensional computational fluid dynamics(CFD) and computational aerodynamic acoustics(CAA) simulation based on FLUENT solver is used to study the influence of surrounding structures upon the aforementioned properties of the unit. The flow rate and sound pressure level are predicted for different rotating speed, and agree well with the experimental results. The parametric influence of three main surrounding structures(i.e. the heat sink, the bell-mouth type shroud and the outlet grille) upon the aerodynamic performance of the unit is analyzed thoroughly. The results demonstrate that the tip vortex plays a major role in the flow fields near the blade tip and has a great effect on the flow field of the unit. The inlet ring's size and throat's depth of the bell-mouth type shroud, and the through-flow area and configuration of upwind and downwind sections of the outlet grille are the most important factors that affect the aerodynamic performance of the unit. Furthermore, two improved schemes against the existing prototype of the unit are developed, which both can significantly increase the flow rate more than 6 %(i.e. 100 m(3) center dot h(-1)) at given rotating speeds. The inevitable increase of flow noise level when flow rate is increased and the advantage of keeping a lower rotating speed are also discussed. The presented work could be a useful guideline in designing the aerodynamic and acoustic performance of the split air-conditioner in engineering practice.
引用
收藏
页码:836 / 845
页数:10
相关论文
共 42 条
  • [21] Effect of the air outlet louver on the noise generated by the outdoor set of a split-unit air conditioner
    Hu, Junwei
    Ding, Guoliang
    APPLIED THERMAL ENGINEERING, 2006, 26 (14-15) : 1737 - 1745
  • [22] Aerodynamic performance improvement of up-flow outdoor unit of air conditioner by redesigning the bell-mouth profile
    Wang, Hao
    Tian, Jie
    Ouyang, Hua
    Wu, Yadong
    Du, Zhaohui
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 46 : 173 - 184
  • [23] Experimental and numerical study on aerodynamic noise of outdoor unit of room air conditioner with different grilles
    Tian, Jie
    Ouyang, Hua
    Wu, Yadong
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2009, 32 (05): : 1112 - 1122
  • [24] Performance evaluation and design considerations for a split air-conditioner with built-in thermal energy storage
    Ahmad, Jehanzeb
    Ul Islam, M. Najam
    Sabir, Jawwad
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2019, 40 (05): : 560 - 575
  • [25] Effect of deflecting ring on noise generated by outdoor set of a split-unit air conditioner
    Hu, JW
    Ding, GL
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (03): : 505 - 513
  • [26] Thermohydraulic and condensing phase-change analysis within the indoor unit of a split-type air-conditioner
    Tsao, Chung-Chun
    Shih, Yang-Cheng
    Lin, Chun-Hsiung
    Chao, Ling-Yu
    Hu, Shih-Cheng
    CASE STUDIES IN THERMAL ENGINEERING, 2020, 21
  • [27] Effects of Bionic Volute Tongue on Aerodynamic Performance and Noise Characteristics of Centrifugal Fan Used in the Air-conditioner
    Liming Wu
    Xiaomin Liu
    Menghao Wang
    Journal of Bionic Engineering, 2020, 17 : 780 - 792
  • [28] Effects of Bionic Volute Tongue on Aerodynamic Performance and Noise Characteristics of Centrifugal Fan Used in the Air-conditioner
    Wu, Liming
    Liu, Xiaomin
    Wang, Menghao
    JOURNAL OF BIONIC ENGINEERING, 2020, 17 (04) : 780 - 792
  • [29] Investigation of air-flow fields and aeroacoustic noise in outdoor unit for split-type air conditioner
    Jiang, Cai-Ling
    Tian, Jie
    Ouyang, Hua
    Chen, Jiang-Ping
    Chen, Zhi-Jiu
    NOISE CONTROL ENGINEERING JOURNAL, 2006, 54 (03) : 146 - 156
  • [30] Prediction of the Energy Savings of a System Combining Air-conditioner's Outdoor Unit with Hydroponic-cultivated Roof Plant
    Wang, Fulin
    Yoshida, Harunori
    Yamashita, Michiko
    6TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS I-III, PROCEEDINGS, 2009, : 419 - 427