Prediction of the Energy Savings of a System Combining Air-conditioner's Outdoor Unit with Hydroponic-cultivated Roof Plant

被引:0
|
作者
Wang, Fulin [1 ]
Yoshida, Harunori [1 ]
Yamashita, Michiko [1 ]
机构
[1] Tsinghua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
关键词
Energy savings; Air-conditioner; Hydroponic-cultivated Roof Plant; Modeling; Simulation; GREEN ROOF;
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
For the purpose of utilizing the cooling effect and solar shading of green roof plants, a system combining the outdoor unit of air-conditioners with green roof plants is proposed. This paper describes the method of predicting the energy savings of the proposed system. An improved leaf transpiration model is developed to estimate how much water can be evaporated by the plant transpiration, and a leaf boundary model is newly developed to estimate how much air temperature can be decreased by the plant transpiration. An experimental system was built using hydroponic-cultivated sweet potato. The solar shading and transpiration-cooling effects are measured and used to verify the accuracy of two newly developed models. The average and root mean square error (RMSE) are 2.9% and 18.8% for transpiration estimation, and 3.3% and 94.0% for estimating air temperature decrease. Further, the specification of six main air-conditioner manufactures are analyzed and divided into to three groups of high, middle and low improvement of energy efficiency accompanying to the outdoor air temperature decrease. Then the cooling loads of a standard office building at four typical climate area of Sapporo, Tokyo, Osaka, and Naha are simulated and used to estimate the energy consumed by the three groups of air-conditioner at the conditions of with and without combining to hydroponic-cultivated roof plant. The results show that the energy saving rates are similar at four different areas, which are about 8% for the high efficiency-improvement group, 6% for middle efficiency-improvement group and 1% for low efficiency-improvement group.
引用
收藏
页码:419 / 427
页数:9
相关论文
共 5 条
  • [1] A novel solar-assisted air-conditioner system for energy savings with performance enhancement
    Ha, Q. P.
    Vakiloroaya, V.
    INTERNATIONAL ENERGY CONGRESS 2012, 2012, 49 : 116 - 123
  • [2] Aerodynamic and aeroacoustic study of collateral axial flow fan system inside outdoor unit of air-conditioner
    Ouyang, Hua
    Tian, Jie
    Wu, Yadong
    Zheng, Zhiming
    Sumio, Shiochi
    Jixie Gongcheng Xuebao/Chinese Journal of Mechanical Engineering, 2007, 43 (10): : 215 - 220
  • [3] Prediction and measurement of axial flow fan aerodynamic and aeroacoustic performance in a split-type air-conditioner outdoor unit
    Zhao, Xifeng
    Sun, Jinju
    Zhang, Zhi
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (03): : 1098 - 1108
  • [4] Flow Field Analysis and Optimization Design of Fan Cover for the Duct System of the Split Air Conditioner's Outdoor Unit
    Ma Jian
    Yang Wang
    Gao Lang
    Wang Honglei
    MECHANICAL ENGINEERING, MATERIALS AND ENERGY III, 2014, 483 : 489 - +
  • [5] Analysis of relative contribution of machinery-induced vibration/ flow-induced vibration to noise radiation from compressor discharging piping system in air-conditioner outdoor unit
    Lee, Sangheon
    Cheong, Cheolung
    Park, Jinhyung
    Lee, Jangwoo
    JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2024, 43 (01): : 122 - 130