Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application

被引:36
|
作者
Gastounioti, A. [1 ]
Golemati, S. [2 ]
Stoitsis, J. S. [1 ]
Nikita, K. S. [1 ]
机构
[1] Natl Tech Univ Athens, Biomed Simulat & Imaging Lab, GR-10682 Athens, Greece
[2] Univ Athens, Sch Med, Intens Care Unit 1, Athina, Greece
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 24期
关键词
PARAMETERS; DISEASE;
D O I
10.1088/0031-9155/58/24/8647
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Valid risk stratification for carotid atherosclerotic plaques represents a crucial public health issue toward preventing fatal cerebrovascular events. Although motion analysis (MA) provides useful information about arterial wall dynamics, the identification of motion-based risk markers remains a significant challenge. Considering that the ability of a motion estimator (ME) to handle changes in the appearance of motion targets has a major effect on accuracy in MA, we investigated the potential of adaptive block matching (ABM) MEs, which consider changes in image intensities over time. To assure the validity in MA, we optimized and evaluated the ABMMEs in the context of a specially designed in silico framework. ABM(FIRF2), which takes advantage of the periodicity characterizing the arterial wall motion, was the most effective ABM algorithm, yielding a 47% accuracy increase with respect to the conventional block matching. The in vivo application of ABM(FIRF2) revealed five potential risk markers: low movement amplitude of the normal part of the wall adjacent to the plaques in the radial (RMA(PWL)) and longitudinal (LMA(PWL)) directions, high radial motion amplitude of the plaque top surface (RMA(PTS)), and high relative movement, expressed in terms of radial strain (RSIPL) and longitudinal shear strain (LSSIPL), between plaque top and bottom surfaces. The in vivo results were reproduced by OFLK((WLS)) and ABM(KF-K2), MEs previously proposed by the authors and with remarkable in silico performances, thereby reinforcing the clinical values of the markers and the potential of those MEs. Future in vivo studies will elucidate with confidence the full potential of the markers.
引用
收藏
页码:8647 / 8661
页数:15
相关论文
共 50 条
  • [41] Texture Characterization of Carotid Atherosclerotic Plaque from B-mode Ultrasound Using Gabor Filters
    Stoitsis, John
    Golemati, Spyretta
    Tsiaparas, Nikolaos
    Nikita, Konstantina S.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 455 - +
  • [42] ROBUST COMMON CAROTID ARTERY LUMEN DETECTION IN B-MODE ULTRASOUND IMAGES USING LOCAL PHASE SYMMETRY
    Rouco, Jose
    Campilho, Aurelio
    2013 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2013, : 929 - 933
  • [43] Fully Automated Common Carotid Artery and Internal Jugular Vein Identification and Tracking Using B-Mode Ultrasound
    Wang, David C.
    Klatzky, Roberta
    Wu, Bing
    Weller, Gregory
    Sampson, Allan R.
    Stetten, George D.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (06) : 1691 - 1699
  • [44] Lumen Segmentation and Motion Estimation in B-Mode and Contrast-Enhanced Ultrasound Images of the Carotid Artery in Patients With Atherosclerotic Plaque
    Carvalho, Diego D. B.
    Akkus, Zeynettin
    van den Oord, Stijn C. H.
    Schinkel, Arend F. L.
    van der Steen, Antonius F. W.
    Niessen, Wiro J.
    Bosch, Johan G.
    Klein, Stefan
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (04) : 983 - 993
  • [45] Noninvasive imaging techniques for the evaluation of aortic arch and carotid artery atherosclerosis in humans: A study with MRI and B-mode ultrasound
    Helft, G
    Worthley, SG
    Weinberger, J
    Zaman, AG
    Fayad, ZA
    Corti, R
    Fuster, V
    Badimon, JJ
    CIRCULATION, 2001, 104 (17) : 671 - 671
  • [46] Implementation of three different segmentation techniques for quantitative evaluation of IMT in B-mode ultrasound common carotid artery images
    Naik, Vaishali
    Gamad, R. S.
    Bansod, Prashant
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING-IMAGING AND VISUALIZATION, 2016, 4 (05): : 317 - 326
  • [47] Evaluation of Freehand B-Mode and Power-Mode 3D Ultrasound for Visualisation and Grading of Internal Carotid Artery Stenosis
    Pelz, Johann Otto
    Weinreich, Anna
    Karlas, Thomas
    Saur, Dorothee
    PLOS ONE, 2017, 12 (01):
  • [48] Automated detection of the carotid artery wall in longitudinal B-mode images using active contours initialized by the Hough transform
    Matsakou, A. I.
    Golemati, S.
    Stoitsis, J. S.
    Nikita, K. S.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 571 - 574
  • [49] Assessment of carotid atherosclerosis from B-mode ultrasound images using directional multiscale texture features
    Tsiaparas, N. N.
    Golemati, S.
    Andreadis, I.
    Stoitsis, J.
    Valavanis, I.
    Nikita, K. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (11)
  • [50] Automated Lumen Segmentation and Estimation of Numerical Attributes of Common Carotid Artery Using Longitudinal B-Mode Ultrasound Images
    Ramasamy, Nandakumar
    Jayanthi, K. B.
    2013 IEEE POINT-OF-CARE HEALTHCARE TECHNOLOGIES (PHT), 2013, : 306 - 309