Carotid artery wall motion analysis from B-mode ultrasound using adaptive block matching: in silico evaluation and in vivo application

被引:36
|
作者
Gastounioti, A. [1 ]
Golemati, S. [2 ]
Stoitsis, J. S. [1 ]
Nikita, K. S. [1 ]
机构
[1] Natl Tech Univ Athens, Biomed Simulat & Imaging Lab, GR-10682 Athens, Greece
[2] Univ Athens, Sch Med, Intens Care Unit 1, Athina, Greece
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2013年 / 58卷 / 24期
关键词
PARAMETERS; DISEASE;
D O I
10.1088/0031-9155/58/24/8647
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Valid risk stratification for carotid atherosclerotic plaques represents a crucial public health issue toward preventing fatal cerebrovascular events. Although motion analysis (MA) provides useful information about arterial wall dynamics, the identification of motion-based risk markers remains a significant challenge. Considering that the ability of a motion estimator (ME) to handle changes in the appearance of motion targets has a major effect on accuracy in MA, we investigated the potential of adaptive block matching (ABM) MEs, which consider changes in image intensities over time. To assure the validity in MA, we optimized and evaluated the ABMMEs in the context of a specially designed in silico framework. ABM(FIRF2), which takes advantage of the periodicity characterizing the arterial wall motion, was the most effective ABM algorithm, yielding a 47% accuracy increase with respect to the conventional block matching. The in vivo application of ABM(FIRF2) revealed five potential risk markers: low movement amplitude of the normal part of the wall adjacent to the plaques in the radial (RMA(PWL)) and longitudinal (LMA(PWL)) directions, high radial motion amplitude of the plaque top surface (RMA(PTS)), and high relative movement, expressed in terms of radial strain (RSIPL) and longitudinal shear strain (LSSIPL), between plaque top and bottom surfaces. The in vivo results were reproduced by OFLK((WLS)) and ABM(KF-K2), MEs previously proposed by the authors and with remarkable in silico performances, thereby reinforcing the clinical values of the markers and the potential of those MEs. Future in vivo studies will elucidate with confidence the full potential of the markers.
引用
收藏
页码:8647 / 8661
页数:15
相关论文
共 50 条
  • [1] Carotid artery wall motion estimated from B-mode ultrasound using region tracking and block matching
    Golemati, S
    Sassano, A
    Lever, MJ
    Bharath, AA
    Dhanjil, S
    Nicolaides, AN
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (03): : 387 - 399
  • [2] A New Approach for Estimating Wall Motion of B-Mode Common Carotid Artery using Block Matching Technique
    Thangavel, M.
    Chandrasekaran, M.
    Madheswaran, M.
    2012 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2012, : 1205 - 1209
  • [3] Carotid artery wall motion in humans, estimated from B-mode ultrasound images
    Golemati, S
    Sassano, A
    Lever, MJ
    Bharath, AA
    Dhanjil, S
    Nicolaides, AN
    JOURNAL OF PHYSIOLOGY-LONDON, 2000, 525 : 11P - 12P
  • [4] Evaluation of a Kalman-based block matching method to assess the bi-dimensional motion of the carotid artery wall in B-mode ultrasound sequences
    Zahnd, Guillaume
    Orkisz, Maciej
    Serusclat, Andre
    Moulin, Philippe
    Vray, Didier
    MEDICAL IMAGE ANALYSIS, 2013, 17 (05) : 573 - 585
  • [5] Carotid Wall Motion Analysis Based on B-Mode Ultrasound Images
    Hopkins, Warren
    Gao, Hao
    Das, Saroj
    Long, Quan
    6TH WORLD CONGRESS OF BIOMECHANICS (WCB 2010), PTS 1-3, 2010, 31 : 871 - 874
  • [6] Multiscale motion analysis of the carotid artery wall from B-mode ultrasound: investigating the optimal wavelet parameterization
    Tsiaparas, N. N.
    Gastounioti, A.
    Golemati, S.
    Nikita, K. S.
    2013 IEEE 13TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOENGINEERING (BIBE), 2013,
  • [7] Dynamic Block Matching to assess the longitudinal component of the dense motion field of the carotid artery wall in B-mode ultrasound sequences - Association with coronary artery disease
    Zahnd, Guillaume
    Saito, Kozue
    Nagatsuka, Kazuyuki
    Otake, Yoshito
    Sato, Yoshinobu
    MEDICAL PHYSICS, 2018, 45 (11) : 5041 - 5053
  • [8] Analysis and quantification of arterial wall motion from B-mode ultrasound images - comparison of block-matching and optical flow
    Stoitsis, J.
    Golemati, S.
    Dimopoulos, A. K.
    Nikita, K. S.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 4469 - 4472
  • [9] Comparison of Kalman-filter-based approaches for block matching in arterial wall motion analysis from B-mode ultrasound
    Gastounioti, A.
    Golemati, S.
    Stoitsis, J.
    Nikita, K. S.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (11)
  • [10] Comparison of Block Matching and Differential Methods for Motion Analysis of the Carotid Artery Wall From Ultrasound Images
    Golemati, Spyretta
    Stoitsis, John S.
    Gastounioti, Aimilia
    Dimopoulos, Alexandros C.
    Koropouli, Vassiliki
    Nikita, Konstantina S.
    IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2012, 16 (05): : 852 - 858