Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization

被引:19
|
作者
Fargier-Voiron, Marie [1 ,2 ,3 ,4 ,5 ,6 ]
Presles, Benoit [1 ,2 ,3 ,4 ,5 ,6 ]
Pommier, Pascal [7 ]
Munoz, Alexandre [7 ]
Rit, Simon [1 ,2 ,3 ,4 ,5 ,6 ]
Sarrut, David [1 ,2 ,3 ,4 ,5 ,6 ]
Biston, Marie-Claude [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Univ Lyon, CREATIS, F-69373 Lyon, France
[2] CNRS, UMR5220, Lyon, France
[3] INSERM, U1044, F-69008 Lyon, France
[4] INSA Lyon, Lyon, France
[5] Univ Lyon 1, F-69365 Lyon, France
[6] Ctr Leon Berard, F-69008 Lyon, France
[7] Univ Lyon, Leon Berard Canc Ctr, F-69373 Lyon, France
来源
关键词
IGRT; Ultrasound; Prostate; Post-prostatectomy; IMPLANTED FIDUCIAL MARKERS; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; CANCER; GUIDANCE; MARGINS; IMPACT;
D O I
10.1016/j.ejmp.2015.07.147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the accuracy of an intra-modality trans-abdominal ultrasound (TA-US) device against soft-tissue based Cone-Beam Computed tomography (CBCT) registration for prostate and post-prostatectomy pre-treatment positioning. Methods: The differences between CBCT and US shifts were calculated on 25 prostate cancer patients (cohort A) and 11 post-prostatectomy patients (cohort B), resulting in 284 and 106 paired shifts for cohorts A and B, respectively. As a second step, a corrective method was applied to the US registration results to decrease the systematic shifts observed between TA-US and CBCT results. This method consisted of subtracting the mean difference obtained between US and CBCT registration results during the first 3 sessions from the US registration results of the subsequent sessions. Inter-operator registration variability (IOV) was also investigated for both modalities. Results: After initial review, about 20% of the US images were excluded because of insufficient quality. The average differences between US and CBCT were: 2.8 +/- 4.1 mm, -0.9 +/- 4.2 mm, 0.4 +/- 3.4 mm for cohort A and 1.3 +/- 5.0 mm, -2.3 +/- 4.6 mm, 0.5 +/- 2.9 mm for cohort B, in the anterior-posterior (AP), superiorinferior (SI) and lateral (LR) directions, respectively. After applying the corrective method, only the differences in the AP direction remained significant (p < 0.05). The IOV values were between 0.6-2.0 mm and 2.1-3.5 mm for the CBCT and TA-US modalities, respectively. Conclusions: Based on the obtained results and on the image quality, the TA-US imaging modality is not safely interchangeable with CBCT for pre-treatment repositioning. Treatment margins adaptation based on the correction of the systematic shifts should be considered. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:997 / 1004
页数:8
相关论文
共 50 条
  • [41] Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy
    Marta Rodríguez Cordón
    Carlos Ferrer Albiach
    Clinical and Translational Oncology, 2009, 11 : 511 - 517
  • [42] Estimate of the shielding effect on secondary cancer risk due to cone-beam CT in image-guided radiotherapy
    Sung, Jiwon
    Baek, Tae Seong
    Yoon, Myonggeun
    Kim, Dong Wook
    Kim, Dong Hyun
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2014, 65 (05) : 757 - 762
  • [43] Cone-beam CT (CBCT) image-guided radiotherapy (IGRT) significantly reduces margins required for stereotactic
    Grills, I.
    Kestin, L.
    Yan, D.
    Chao, K.
    Wloch, J.
    Hugo, G.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S62 - S62
  • [44] Fast kilovoltage/megavoltage (kVMV) breathhold cone-beam CT for image-guided radiotherapy of lung cancer
    Wertz, Hansjoerg
    Stsepankou, Dzmitry
    Blessing, Manuel
    Rossi, Michael
    Knox, Chris
    Brown, Kevin
    Gros, Uwe
    Boda-Heggemann, Judit
    Walter, Cornelia
    Hesser, Juergen
    Lohr, Frank
    Wenz, Frederik
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (15): : 4203 - 4217
  • [45] Clinical introduction of image-guided radiotherapy, IGRT with cone beam CT
    Sorcini, B
    Odh, R
    Näfstadius, P
    Näslund, I
    Wersäll, P
    Tilikidis, A
    Severin, AC
    Isoz, A
    Fjällman, P
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S103 - S103
  • [46] Theoretical aspects of implementation of kilovoltage cone-beam CT onboard linear accelerator for image-guided radiotherapy
    Rodriguez Cordon, Marta
    Ferrer Albiach, Carlos
    CLINICAL & TRANSLATIONAL ONCOLOGY, 2009, 11 (08): : 511 - 517
  • [47] Comparison study of portable bladder scanner versus cone-beam CT scan for measuring bladder volumes in post-prostatectomy patients undergoing radiotherapy
    Ung, K. A.
    White, R.
    Mathlum, M.
    Mak-Hau, V.
    Lynch, R.
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2014, 58 (03) : 377 - 383
  • [48] Target localization for post-prostatectomy patients using CT and ultrasound image guidance
    Paskalev, Kamen
    Feigenberg, Steven
    Jacob, Rojymon
    McNeeley, Shawn
    Horwitz, Eric
    Price, Robert
    Ma, Charlie
    Pollack, Alan
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2005, 6 (04): : 40 - 49
  • [49] Evaluation of ultrasound-based prostate localization for image-guided radiotherapy
    Langen, KM
    Pouliot, J
    Anezinos, C
    Aubin, M
    Gottschalk, AR
    Hsu, IC
    Lowther, D
    Liu, YM
    Shinohara, K
    Verhey, LJ
    Weinberg, V
    Roach, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2003, 57 (03): : 635 - 644
  • [50] Investigation of uncertainties in image registration of cone beam CT to CT on an image-guided radiotherapy system
    Sykes, J. R.
    Brettle, D. S.
    Magee, D. R.
    Thwaites, D. I.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (24): : 7263 - 7283