Ultrasound versus Cone-beam CT image-guided radiotherapy for prostate and post-prostatectomy pretreatment localization

被引:19
|
作者
Fargier-Voiron, Marie [1 ,2 ,3 ,4 ,5 ,6 ]
Presles, Benoit [1 ,2 ,3 ,4 ,5 ,6 ]
Pommier, Pascal [7 ]
Munoz, Alexandre [7 ]
Rit, Simon [1 ,2 ,3 ,4 ,5 ,6 ]
Sarrut, David [1 ,2 ,3 ,4 ,5 ,6 ]
Biston, Marie-Claude [1 ,2 ,3 ,4 ,5 ,6 ]
机构
[1] Univ Lyon, CREATIS, F-69373 Lyon, France
[2] CNRS, UMR5220, Lyon, France
[3] INSERM, U1044, F-69008 Lyon, France
[4] INSA Lyon, Lyon, France
[5] Univ Lyon 1, F-69365 Lyon, France
[6] Ctr Leon Berard, F-69008 Lyon, France
[7] Univ Lyon, Leon Berard Canc Ctr, F-69373 Lyon, France
来源
关键词
IGRT; Ultrasound; Prostate; Post-prostatectomy; IMPLANTED FIDUCIAL MARKERS; COMPUTED-TOMOGRAPHY; RADIATION-THERAPY; CANCER; GUIDANCE; MARGINS; IMPACT;
D O I
10.1016/j.ejmp.2015.07.147
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To evaluate the accuracy of an intra-modality trans-abdominal ultrasound (TA-US) device against soft-tissue based Cone-Beam Computed tomography (CBCT) registration for prostate and post-prostatectomy pre-treatment positioning. Methods: The differences between CBCT and US shifts were calculated on 25 prostate cancer patients (cohort A) and 11 post-prostatectomy patients (cohort B), resulting in 284 and 106 paired shifts for cohorts A and B, respectively. As a second step, a corrective method was applied to the US registration results to decrease the systematic shifts observed between TA-US and CBCT results. This method consisted of subtracting the mean difference obtained between US and CBCT registration results during the first 3 sessions from the US registration results of the subsequent sessions. Inter-operator registration variability (IOV) was also investigated for both modalities. Results: After initial review, about 20% of the US images were excluded because of insufficient quality. The average differences between US and CBCT were: 2.8 +/- 4.1 mm, -0.9 +/- 4.2 mm, 0.4 +/- 3.4 mm for cohort A and 1.3 +/- 5.0 mm, -2.3 +/- 4.6 mm, 0.5 +/- 2.9 mm for cohort B, in the anterior-posterior (AP), superiorinferior (SI) and lateral (LR) directions, respectively. After applying the corrective method, only the differences in the AP direction remained significant (p < 0.05). The IOV values were between 0.6-2.0 mm and 2.1-3.5 mm for the CBCT and TA-US modalities, respectively. Conclusions: Based on the obtained results and on the image quality, the TA-US imaging modality is not safely interchangeable with CBCT for pre-treatment repositioning. Treatment margins adaptation based on the correction of the systematic shifts should be considered. (C) 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:997 / 1004
页数:8
相关论文
共 50 条
  • [21] IMAGE-GUIDED RADIOTHERAPY (IGRT) BY CONE-BEAM CT (CBCT) IN PROSTATE CANCER PATIENTS: DAILY OR WEEKLY VERIFICATION?
    Ferrer Gonzalez, F.
    Ballivy, O.
    Sancho, I.
    Boladeras Inglada, A. M.
    Leon, P. R.
    Gutierrez, C.
    Martinez, E.
    Gonzalez Imhoff, M. N.
    Prat, X.
    Pera, J.
    Guedea, F.
    RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S404 - S405
  • [22] A feature alignment score for online cone-beam CT-based image-guided radiotherapy for prostate cancer
    Hargrave, Catriona
    Deegan, Timothy
    Poulsen, Michael
    Bednarz, Tomasz
    Harden, Fiona
    Mengersen, Kerrie
    MEDICAL PHYSICS, 2018, 45 (07) : 2898 - 2911
  • [23] Evaluating daily cone-beam CT image-guided radiotherapy after prostatectomy: Can we reduce the PTV margin?
    Chu, W.
    Craig, T.
    Moseley, D.
    Brock, K.
    Bayley, A.
    Catton, C.
    Chung, P.
    Gospodarowicz, M.
    Milosevic, M.
    Warde, P.
    Menard, C.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S44 - S44
  • [24] Dynamic Region-of-Interest Cone-Beam CT for Image-Guided Postmastectomy Radiotherapy
    Pearson, Erik
    Al-Hallaq, Hania
    Pan, Xiaochuan
    Pelizzari, Charles
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3187 - 3190
  • [25] Prostate Image-Guided Radiotherapy by Megavolt Cone-Beam CTBildgeführte Radiotherapie der Prostata mit Megavolt-Cone-Beam-CT
    Sergio Zucca
    Barbara Carau
    Ignazio Solla
    Elisabetta Garibaldi
    Paolo Farace
    Giancarlo Lay
    Gianfranco Meleddu
    Pietro Gabriele
    Strahlentherapie und Onkologie, 2011, 187 (8) : 473 - 478
  • [26] Comparison of cone beam CT imaging protocols in image-guided radiotherapy for prostate cancer
    Ariyaratne, H.
    Chesham, H.
    Pettingell, J.
    Sikora, K.
    Alonzi, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S666 - S667
  • [27] Deformable image registration for cone-beam CT (CBCT) images for implemantion of image-guided adaptive radiotherapy
    Zhang, L.
    Dong, L.
    Ahamad, A.
    Zhu, X. R.
    Garden, A. S.
    Ang, K. K.
    Mohan, R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S647 - S648
  • [28] Personalized organ dose assessment of cone-beam CT imaging for image-guided thoracic radiotherapy
    Zhang, Y.
    Wu, H.
    Chen, Z.
    Knisely, J.
    Nath, R.
    Feng, Z.
    Bao, S.
    Deng, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S266 - S266
  • [29] Investigation of the radiation dose from cone-beam CT for image-guided radiotherapy: A comparison of methodologies
    Buckley, Jarryd G.
    Wilkinson, Dean
    Malaroda, Alessandra
    Metcalfe, Peter
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (01): : 174 - 183
  • [30] Contrast-enhanced respiration managed cone-beam CT for image-guided intrahepatic radiotherapy
    Lock, M.
    Jensen, N.
    Kozak, R.
    Chen, J.
    Lee, T.
    Wong, E.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S175 - S176