Ultra-trace plutonium determination in small volume seawater by sector field inductively coupled plasma mass spectrometry with application to Fukushima seawater samples

被引:35
|
作者
Bu, Wenting [1 ,2 ]
Zheng, Jian [2 ]
Guo, Qiuju [1 ]
Aono, Tatsuo [3 ]
Tagami, Keiko [2 ]
Uchida, Shigeo [2 ]
Tazoe, Hirofumi [4 ]
Yamada, Masatoshi [4 ]
机构
[1] Peking Univ, Sch Phys, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[2] Natl Inst Radiol Sci, Res Ctr Radiat Protect, Inage Ku, Chiba 2638555, Japan
[3] Natl Inst Radiol Sci, Fukushima Project Headquarters, Inage Ku, Chiba 2638555, Japan
[4] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Chem, Hirosaki, Aomori 0368564, Japan
基金
中国国家自然科学基金;
关键词
Plutonium; Seawater; Anion-exchange chromatography; SF-ICP-MS; FDNPP; NUCLEAR-POWER-PLANT; PU-240/PU-239; ISOTOPIC-RATIOS; PU ISOTOPES; ATOM RATIOS; PACIFIC-OCEAN; ICP-MS; RADIONUCLIDES; CS-137; SEPARATION; IMPACTS;
D O I
10.1016/j.chroma.2014.02.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Long-term monitoring of Pu isotopes in seawater is required for assessing Pu contamination in the marine environment from the Fukushima Dai-ichi Nuclear Power Plant accident. In this study, we established an accurate and precise analytical method based on anion-exchange chromatography and SF-ICP-MS. This method was able to determine Pu isotopes in seawater samples with small volumes (20-60L). The U decontamination factor was 3 x 10(7)-1 x 10(8), which provided sufficient removal of interfering U from the seawater samples. The estimated limits of detection for (PU)-P-239 and Pu-240 were 0.11 fgmL(-1) and 0.08 fg mL(-1), respectively, which corresponded to 0.01 mBq m(-3) for (PU)-P-239 and 0.03 mBq m(-3) for (240)pu when a 20 L volume of seawater was measured. We achieved good precision (2.9%) and accuracy (0.8%) for measurement of the (PU)-P-240/2(39)PU atom ratio in the standard Pu solution with a (PU)-P-239 concentration of 11 fg mL(-1) and Pu-240 concentration of 2.7 fg mL(-1). Seawater reference materials were used for the method validation and both the Pu239+240 activities and Pu-240/Pu-239 atom ratios agreed well with the expected values. Surface and bottom seawater samples collected off Fukushima in the western North Pacific since March 2011 were analyzed. Our results suggested that there was no significant variation of the Pu distribution in seawater in the investigated areas compared to the distribution before the accident. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 50 条
  • [41] Multielement determination of trace elements in coastal seawater by inductively coupled plasma mass spectrometry with aid of chelating resin preconcentration
    Yabutani, T
    Ji, S
    Mouri, F
    Sawatari, H
    Itoh, A
    Chiba, K
    Haraguchi, H
    BULLETIN OF THE CHEMICAL SOCIETY OF JAPAN, 1999, 72 (10) : 2253 - 2260
  • [42] Determination of ultra-trace sulfur in high-purity metals by isotope dilution inductively coupled plasma sector field mass spectrometry combined with chemical separation procedure
    Wada, Ayaka
    Nonose, Naoko
    Ohata, Masaki
    Miura, Tsutomu
    TALANTA, 2018, 189 : 289 - 295
  • [43] MULTIELEMENT DETERMINATION OF TRACE-ELEMENTS IN SEAWATER BY GALLIUM COPRECIPITATION AND INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY
    SAWATARI, H
    FUJIMORI, E
    HARAGUCHI, H
    ANALYTICAL SCIENCES, 1995, 11 (03) : 369 - 374
  • [44] Multielement determination of trace elements in coastal seawater by inductively coupled plasma mass spectrometry with aid of chelating resin preconcentration
    Department of Applied Chemistry, Graduate School of Engineering, Nagoya University, Furo-cho, Chikusa-ku, Nagoya 464-8603, Japan
    不详
    Bull. Chem. Soc. Jpn., 10 (2253-2260):
  • [45] Direct measurement of uranium in seawater by inductively coupled plasma mass spectrometry
    Qiao, Jixin
    Xu, Yihong
    TALANTA, 2018, 183 : 18 - 23
  • [46] High resolution inductively coupled plasma mass spectrometry for the trace determination of plutonium isotopes and isotope ratios in environmental samples
    Stürup, S
    Dahlgaard, H
    Nielsen, SC
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (12) : 1321 - 1326
  • [47] Improved immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber and application of the material to the determination of trace metals in seawater by inductively coupled plasma mass spectrometry
    Bei Wen
    Xiao-quan Shan
    Analytical and Bioanalytical Chemistry, 2002, 374 : 948 - 954
  • [48] Improved immobilization of 8-hydroxyquinoline on polyacrylonitrile fiber and application of the material to the determination of trace metals in seawater by inductively coupled plasma mass spectrometry
    Wen, B
    Shan, X
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (05) : 948 - 954
  • [49] Determination of ultra-trace level plutonium isotopes in soil samples by triple-quadrupole inductively coupled plasma-mass spectrometry with mass-shift mode combined with UTEVA chromatographic separation
    Zhang, Weichao
    Lin, Jianfeng
    Fang, Sui
    Li, Chen
    Yi, Xiaowei
    Hou, Xiaolin
    Chen, Ning
    Zhang, Haitao
    Xu, Yihong
    Dang, Haijun
    Wang, Wei
    Xu, Jiang
    TALANTA, 2021, 234
  • [50] Sample Pretreatment Using Chitosan-based Chelating Resin for the Determination of Trace Metals in Seawater Samples by Inductively Coupled Plasma-Mass Spectrometry
    Rosi Ketrin Katarina
    Toshio Takayanagi
    Koji Oshita
    Mitsuko Oshima
    Shoji Motomizu
    Analytical Sciences, 2008, 24 : 1537 - 1544