Ultra-trace plutonium determination in small volume seawater by sector field inductively coupled plasma mass spectrometry with application to Fukushima seawater samples

被引:35
|
作者
Bu, Wenting [1 ,2 ]
Zheng, Jian [2 ]
Guo, Qiuju [1 ]
Aono, Tatsuo [3 ]
Tagami, Keiko [2 ]
Uchida, Shigeo [2 ]
Tazoe, Hirofumi [4 ]
Yamada, Masatoshi [4 ]
机构
[1] Peking Univ, Sch Phys, State Key Lab Nucl Phys & Technol, Beijing 100871, Peoples R China
[2] Natl Inst Radiol Sci, Res Ctr Radiat Protect, Inage Ku, Chiba 2638555, Japan
[3] Natl Inst Radiol Sci, Fukushima Project Headquarters, Inage Ku, Chiba 2638555, Japan
[4] Hirosaki Univ, Inst Radiat Emergency Med, Dept Radiat Chem, Hirosaki, Aomori 0368564, Japan
基金
中国国家自然科学基金;
关键词
Plutonium; Seawater; Anion-exchange chromatography; SF-ICP-MS; FDNPP; NUCLEAR-POWER-PLANT; PU-240/PU-239; ISOTOPIC-RATIOS; PU ISOTOPES; ATOM RATIOS; PACIFIC-OCEAN; ICP-MS; RADIONUCLIDES; CS-137; SEPARATION; IMPACTS;
D O I
10.1016/j.chroma.2014.02.066
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Long-term monitoring of Pu isotopes in seawater is required for assessing Pu contamination in the marine environment from the Fukushima Dai-ichi Nuclear Power Plant accident. In this study, we established an accurate and precise analytical method based on anion-exchange chromatography and SF-ICP-MS. This method was able to determine Pu isotopes in seawater samples with small volumes (20-60L). The U decontamination factor was 3 x 10(7)-1 x 10(8), which provided sufficient removal of interfering U from the seawater samples. The estimated limits of detection for (PU)-P-239 and Pu-240 were 0.11 fgmL(-1) and 0.08 fg mL(-1), respectively, which corresponded to 0.01 mBq m(-3) for (PU)-P-239 and 0.03 mBq m(-3) for (240)pu when a 20 L volume of seawater was measured. We achieved good precision (2.9%) and accuracy (0.8%) for measurement of the (PU)-P-240/2(39)PU atom ratio in the standard Pu solution with a (PU)-P-239 concentration of 11 fg mL(-1) and Pu-240 concentration of 2.7 fg mL(-1). Seawater reference materials were used for the method validation and both the Pu239+240 activities and Pu-240/Pu-239 atom ratios agreed well with the expected values. Surface and bottom seawater samples collected off Fukushima in the western North Pacific since March 2011 were analyzed. Our results suggested that there was no significant variation of the Pu distribution in seawater in the investigated areas compared to the distribution before the accident. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:171 / 178
页数:8
相关论文
共 50 条
  • [31] Direct Determination of Trace Lead in Seawater by Inductively Coupled Plasma Mass Spectrometry After Photochemical Vapor Generation
    Li, Shuzhen
    Gao, Ying
    Yu, Ying
    He, Hongyan
    Hu, Xiaorong
    Ni, Shijun
    Shi, Zeming
    Peng, Xiuhong
    Liu, Rui
    ATOMIC SPECTROSCOPY, 2017, 38 (03) : 37 - 43
  • [32] Rapid determination of ultra-trace plutonium isotopes (239Pu, 240Pu and 241Pu) in small-volume human urine bioassay using sector-field inductively coupled plasma mass spectrometry
    Ni, Youyi
    Zheng, Jian
    Guo, Qiuju
    Men, Wu
    Tagami, Keiko
    Uchida, Shigeo
    ANALYTICA CHIMICA ACTA, 2018, 1000 : 85 - 92
  • [33] Determination and Evaluation of Ultra-trace Levels of Titanium in Bearing Steel by Inductively Coupled Plasma Tandem Mass Spectrometry
    Wang, Dan
    Li, Hui
    Guo, Lili
    Guo, Hongjie
    Li, Xiaoxu
    Li, Sisi
    Zhang, Zhongyuan
    ATOMIC SPECTROSCOPY, 2024, 45 (06)
  • [34] USE OF INDUCTIVELY-COUPLED PLASMA-MASS SPECTROMETRY FOR THE DETERMINATION OF ULTRA-TRACE ELEMENTS IN HUMAN SERUM
    VANHOE, H
    DAMS, R
    VERSIECK, J
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1994, 9 (01) : 23 - 31
  • [35] Matrix elimination for the determination of uranium in seawater using inductively coupled plasma mass spectrometry
    Wood, Jordana
    Gill, Gary
    Choe, Key-Young
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 249
  • [36] Determination of mercury and thallium in seawater by electrothermal vaporization inductively coupled plasma mass spectrometry
    Liu, HW
    Jiang, SJ
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2000, 47 (03) : 481 - 488
  • [37] LASER ABLATION INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY - A NEW TECHNIQUE FOR THE DETERMINATION OF TRACE AND ULTRA-TRACE ELEMENTS IN SILICATES
    PERKINS, WT
    PEARCE, NJG
    JEFFRIES, TE
    GEOCHIMICA ET COSMOCHIMICA ACTA, 1993, 57 (02) : 475 - 482
  • [38] Preconcentration and determination of trace metals in seawater using a thiol cotton fiber minicolumn coupled with inductively coupled plasma mass spectrometry
    Zhang, SZ
    Lu, AX
    Han, F
    Shan, XQ
    ANALYTICAL SCIENCES, 2005, 21 (06) : 651 - 654
  • [39] Preconcentration and Determination of Trace Metals in Seawater Using a Thiol Cotton Fiber Minicolumn Coupled with Inductively Coupled Plasma Mass Spectrometry
    Shuzhen Zhang
    Anxiang Lu
    Fang Han
    Xiao-quan Shan
    Analytical Sciences, 2005, 21 : 651 - 654
  • [40] Multi-elemental determination of trace elements in deep seawater by inductively coupled plasma mass spectrometry with resin preconcentration
    Sumida, T
    Nakazato, T
    Tao, H
    BUNSEKI KAGAKU, 2003, 52 (08) : 619 - 626