Measuring intraocular pressure by different methods

被引:0
|
作者
Lamparter, J. [1 ]
Hoffmann, E. M. [1 ]
机构
[1] Univ Augenklin Mainz, D-55131 Mainz, Germany
来源
OPHTHALMOLOGE | 2009年 / 106卷 / 08期
关键词
Glaucoma; Tonometry; Intraocular Pressure; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; TRANSPALPEBRAL TONOMETRY; TGDC-01; ICARE;
D O I
10.1007/s00347-009-1971-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Tonometry is the measurement of intraocular pressure (IOP). Normal IOP values range from 10 to 21 mmHg (15.5 mmHg +/- 2 SD). They are influenced by various factors, including the patient's position during measurement, central corneal thickness, corneal diameter and curvature, rigidity of the cornea, and the cornea's state of hydration. Until now, Goldmann applanation tonometry has been seen as the gold standard for intraocular pressure measurement. But many new techniques and devices for determining IOP have been developed, such as noncontact tonometry, the To-no-Pen, the ICare tonometer, dynamic con-tour tonometry, TGDc-01 tonometry, and the ocular response analyzer. The aim of these techniques is to minimize distorting influences to obtain the "true IOP." Several of these methods show advantages in specific situations; however, limitations exist that should be considered when interpreting the obtained IOP results. This article describes the individual methods of measurement and discusses their advantages and disadvantages.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
  • [1] Methods for measuring intraocular pressure in the family practice
    Grehn, F
    INTERNIST, 2002, 43 (10): : 1298 - 1298
  • [2] Methods of measuring intraocular pressure independently of central corneal thickness
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2008, 105 (09): : 840 - 844
  • [3] Measuring intraocular pressure
    McDonald, J. E. Jay, II
    ANNALS OF OPHTHALMOLOGY, 2006, 38 (01) : 5 - 8
  • [4] Measuring intraocular pressure
    Okafor, Kingsley C.
    Brandt, James D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 103 - 109
  • [5] THE EFFECT OF DIFFERENT METHODS OF INDUCING ANESTHESIA ON INTRAOCULAR-PRESSURE
    BADRINATH, SK
    VAZEERY, A
    MCCARTHY, RJ
    IVANKOVICH, AD
    ANESTHESIOLOGY, 1986, 65 (04) : 431 - 435
  • [6] PERIMETRIC AND VISUMETRIC METHODS FOR MEASURING INDIVIDUALLY TOLERATED INTRAOCULAR-PRESSURE IN GLAUCOMA
    VODOVOZOV, AM
    ANIDALOVA, GB
    PILIPJANKO, SK
    BORISKINA, LN
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1982, 180 (06) : 548 - 550
  • [7] Impact of corneal parameters on intraocular pressure measurements in different tonometry methods
    Aleksandra Zakrzewska
    Marta P.Wi?cek
    Anna Machalińska
    International Journal of Ophthalmology, 2019, (12) : 1853 - 1858
  • [8] Impact of corneal parameters on intraocular pressure measurements in different tonometry methods
    Zakrzewska, Aleksandra
    Wiacek, Marta P.
    Machalinska, Anna
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (12) : 1853 - 1858
  • [9] New technologies for measuring intraocular pressure
    Garcia-Feijoo, Julian
    Martinez-de-la-Casa, Jose Maria
    Morales-Fernandez, Laura
    Frances, Federico Saenz
    Santos-Bueso, Enrique
    Garcia-Saenz, Sofia
    Mendez-Hernandez, Carmen
    NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B, 2015, 221 : 67 - 79
  • [10] A Dynamic Tonometer for Measuring Intraocular Pressure
    Dikin V.I.
    Ivanyschev C.V.
    Kornev N.P.
    Mikheev A.A.
    Solomakha V.N.
    Biomedical Engineering, 2013, 47 (03) : 130 - 133