New technologies for measuring intraocular pressure

被引:14
|
作者
Garcia-Feijoo, Julian [1 ,2 ]
Martinez-de-la-Casa, Jose Maria [1 ,2 ]
Morales-Fernandez, Laura [1 ,2 ]
Frances, Federico Saenz [1 ,2 ]
Santos-Bueso, Enrique [1 ,2 ]
Garcia-Saenz, Sofia [1 ,2 ]
Mendez-Hernandez, Carmen [1 ,2 ]
机构
[1] Univ Complutense Madrid, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Hosp Clin San Carlos, Dept Oftalmol & ORL,Fac Med,Serv Oftalmol, Madrid, Spain
[2] Inst Salud Carlos III, Cooperat Res Network Age Related Ocular Pathol Vi, Madrid, Spain
关键词
Intraocular pressure; Tonometer; Goldmann; Corneal thickness; Corneal hysteresis; Dynamic contour; Pascal; Corvis; Ocular response analyzer; ICare; Rebound; Sensimed; GOLDMANN APPLANATION TONOMETRY; OCULAR HYPERTENSION TREATMENT; DYNAMIC CONTOUR TONOMETRY; CORNEAL THICKNESS; REBOUND TONOMETER; ICARE; NONCONTACT; TGDC-01; ONSET;
D O I
10.1016/bs.pbr.2015.06.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The level of intraocular pressure (IOP) is the main known risk factor for the development and progression of glaucomatous optic neuropathy. Despite Goldmann applanation tonometry (GAT) being the gold standard for determining IOP since the last century, its limitations were obvious from the start and include substantial effects of several eye variables such as axial length, curvature, rigidity, and corneal thickness. These limitations have prompted the development of numerous formulas and nomograms designed to compensate for the ocular characteristics effect on GAT, but none of these methods has been entirely satisfactory. Similarly, as a result of efforts to mitigate some of the limitations of conventional tonometry, several new tonometers have appeared on the scene.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [1] Measuring intraocular pressure-adjustments for corneal thickness and new technologies
    Herndon, Leon W.
    CURRENT OPINION IN OPHTHALMOLOGY, 2006, 17 (02) : 115 - 119
  • [2] A new electromechanical method for measuring intraocular pressure
    Kontiola, A
    DOCUMENTA OPHTHALMOLOGICA, 1997, 93 (03) : 265 - 276
  • [3] A new electromechanical method for measuring intraocular pressure
    Antti Kontiola
    Documenta Ophthalmologica, 1997, 93 : 265 - 276
  • [4] Measuring intraocular pressure
    McDonald, J. E. Jay, II
    ANNALS OF OPHTHALMOLOGY, 2006, 38 (01) : 5 - 8
  • [5] Measuring intraocular pressure
    Okafor, Kingsley C.
    Brandt, James D.
    CURRENT OPINION IN OPHTHALMOLOGY, 2015, 26 (02) : 103 - 109
  • [6] New laser technologies in ophthalmology for normalisation of intraocular pressure and correction of refraction
    Baum, O. I.
    Yuzhakov, A. V.
    Bolshunov, A. V.
    Siplivyi, V. I.
    Khomchik, O. V.
    Zheltov, G. I.
    Sobol, E. N.
    QUANTUM ELECTRONICS, 2017, 47 (09) : 860 - 866
  • [7] Design and Simulation of New Micro-Electromechanical Pressure Sensor for Measuring Intraocular Pressure
    Shahiri-Tabarestani, M.
    Ganji, B. A.
    Sabbaghi-Nadooshan, R.
    2012 16TH IEEE MEDITERRANEAN ELECTROTECHNICAL CONFERENCE (MELECON), 2012, : 208 - 211
  • [8] Evaluation of a new transpalpebral tonometer for self-measuring intraocular pressure
    Kobashi, Hidenaga
    PLOS ONE, 2024, 19 (05):
  • [9] Evaluation of the New Digital Goldmann Applanation Tonometer for Measuring Intraocular Pressure
    Sakaue, Yuta
    Ueda, Jun
    Seki, Masaaki
    Tanaka, Takayuki
    Togano, Tetsuya
    Yoshino, Takaiko
    Fukuchi, Takeo
    JOURNAL OF OPHTHALMOLOGY, 2014, 2014
  • [10] A new induction-based impact method for measuring intraocular pressure
    Kontiola, AI
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2000, 78 (02): : 142 - 145