New technologies for measuring intraocular pressure

被引:14
|
作者
Garcia-Feijoo, Julian [1 ,2 ]
Martinez-de-la-Casa, Jose Maria [1 ,2 ]
Morales-Fernandez, Laura [1 ,2 ]
Frances, Federico Saenz [1 ,2 ]
Santos-Bueso, Enrique [1 ,2 ]
Garcia-Saenz, Sofia [1 ,2 ]
Mendez-Hernandez, Carmen [1 ,2 ]
机构
[1] Univ Complutense Madrid, Inst Invest Sanitaria Hosp Clin San Carlos IdISSC, Hosp Clin San Carlos, Dept Oftalmol & ORL,Fac Med,Serv Oftalmol, Madrid, Spain
[2] Inst Salud Carlos III, Cooperat Res Network Age Related Ocular Pathol Vi, Madrid, Spain
关键词
Intraocular pressure; Tonometer; Goldmann; Corneal thickness; Corneal hysteresis; Dynamic contour; Pascal; Corvis; Ocular response analyzer; ICare; Rebound; Sensimed; GOLDMANN APPLANATION TONOMETRY; OCULAR HYPERTENSION TREATMENT; DYNAMIC CONTOUR TONOMETRY; CORNEAL THICKNESS; REBOUND TONOMETER; ICARE; NONCONTACT; TGDC-01; ONSET;
D O I
10.1016/bs.pbr.2015.06.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The level of intraocular pressure (IOP) is the main known risk factor for the development and progression of glaucomatous optic neuropathy. Despite Goldmann applanation tonometry (GAT) being the gold standard for determining IOP since the last century, its limitations were obvious from the start and include substantial effects of several eye variables such as axial length, curvature, rigidity, and corneal thickness. These limitations have prompted the development of numerous formulas and nomograms designed to compensate for the ocular characteristics effect on GAT, but none of these methods has been entirely satisfactory. Similarly, as a result of efforts to mitigate some of the limitations of conventional tonometry, several new tonometers have appeared on the scene.
引用
收藏
页码:67 / 79
页数:13
相关论文
共 50 条
  • [31] New perspectives on target intraocular pressure
    Clement, Colin I.
    Bhartiya, Shibal
    Shaarawy, Tarek
    SURVEY OF OPHTHALMOLOGY, 2014, 59 (06) : 615 - 626
  • [32] New insights into the regulation of intraocular pressure
    Reitsamer, Herbert A.
    Kiel, J.W.
    1600, De Gruyter Open Ltd (48):
  • [33] New ways to measure intraocular pressure
    ElMallah, Mohammed K.
    Asrani, Sanjay G.
    CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) : 122 - 126
  • [34] NEW WAYS OF INFLUENCING THE INTRAOCULAR PRESSURE
    STOCKER, FW
    NEW YORK STATE JOURNAL OF MEDICINE, 1949, 49 (01) : 58 - 63
  • [35] Comparison of three methodologies for measuring intraocular pressure in healthy cats
    Ricci, Claudia Lizandra
    Passareli, Joao Victor Goulart Consoni
    Nascimento, Felipe Franco
    Kanashiro, Glaucia Prada
    Zulim, Luis Felipe da Costa
    Giuffrida, Rogerio
    Andrade, Silvia Franco
    VETERINARY WORLD, 2024, 17 (08) : 1803 - 1809
  • [36] Methods of measuring intraocular pressure independently of central corneal thickness
    Hager, A.
    Wiegand, W.
    OPHTHALMOLOGE, 2008, 105 (09): : 840 - 844
  • [37] WHY IS THE SCHIOTZ TONOMETER NOT SUITABLE FOR MEASURING INTRAOCULAR-PRESSURE
    STEPANIK, J
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1980, 176 (01) : 61 - 66
  • [38] Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horses
    Knollinger, AM
    La Croix, NC
    Barrett, PM
    Miller, PE
    JAVMA-JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 2005, 227 (02): : 244 - 248
  • [39] Measuring Intraocular Pressure with Disposable Versus Reusable Applanator Prisms
    Richard, Gregory
    Crowder, Kimberly Williams
    Idowu, Omalola
    Jimenez, Jorge
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [40] Mathematical Modeling of Maklakoff's Method for Measuring the Intraocular Pressure
    Bauer, S. M.
    Lyubimov, G. A.
    Tovstik, P. E.
    FLUID DYNAMICS, 2005, 40 (01) : 20 - 33