Measuring intraocular pressure by different methods

被引:0
|
作者
Lamparter, J. [1 ]
Hoffmann, E. M. [1 ]
机构
[1] Univ Augenklin Mainz, D-55131 Mainz, Germany
来源
OPHTHALMOLOGE | 2009年 / 106卷 / 08期
关键词
Glaucoma; Tonometry; Intraocular Pressure; GOLDMANN APPLANATION TONOMETRY; DYNAMIC CONTOUR TONOMETRY; TRANSPALPEBRAL TONOMETRY; TGDC-01; ICARE;
D O I
10.1007/s00347-009-1971-8
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Tonometry is the measurement of intraocular pressure (IOP). Normal IOP values range from 10 to 21 mmHg (15.5 mmHg +/- 2 SD). They are influenced by various factors, including the patient's position during measurement, central corneal thickness, corneal diameter and curvature, rigidity of the cornea, and the cornea's state of hydration. Until now, Goldmann applanation tonometry has been seen as the gold standard for intraocular pressure measurement. But many new techniques and devices for determining IOP have been developed, such as noncontact tonometry, the To-no-Pen, the ICare tonometer, dynamic con-tour tonometry, TGDc-01 tonometry, and the ocular response analyzer. The aim of these techniques is to minimize distorting influences to obtain the "true IOP." Several of these methods show advantages in specific situations; however, limitations exist that should be considered when interpreting the obtained IOP results. This article describes the individual methods of measurement and discusses their advantages and disadvantages.
引用
收藏
页码:676 / 682
页数:7
相关论文
共 50 条
  • [31] Intraocular Pressure Measuring System Based on Piezoelectric Bimorph
    Tong, Yue
    Xia, Zhengrong
    2012 INTERNATIONAL CONFERENCE ON FUTURE ENERGY, ENVIRONMENT, AND MATERIALS, PT B, 2012, 16 : 1288 - 1294
  • [32] Measuring intraocular pressure using semiconductor laser autodyne
    Usanov, D. A.
    Skripal', An. V.
    Usanova, T. B.
    Dobdin, S. Yu.
    TECHNICAL PHYSICS LETTERS, 2012, 38 (02) : 135 - 137
  • [33] Measuring intraocular pressure using semiconductor laser autodyne
    D. A. Usanov
    An. V. Skripal’
    T. B. Usanova
    S. Yu. Dobdin
    Technical Physics Letters, 2012, 38 : 135 - 137
  • [34] BLOOD PRESSURE MEASURING METHODS
    SHIRER, HW
    IRE TRANSACTIONS ON BIOMEDICAL ELECTRONICS, 1962, BME9 (02): : 116 - &
  • [35] MEASURING METHODS OF BRA PRESSURE
    Ng Sun-pui
    Albert, Au
    Zhou Jie
    Yu Winnie
    86TH TEXTILE INSTITUTE WORLD CONFERENCE, VOL 4, CONFERENCE PROCEEDINGS, 2008, : 2568 - 2578
  • [36] METHODS OF MEASURING WATER PRESSURE
    SUDNITSY.II
    SOVIET SOIL SCIENCE-USSR, 1968, (08): : 1162 - &
  • [37] Comparison of acceptability of and preferences for different methods of measuring blood pressure in primary care
    Little, P
    Barnett, J
    Barnsley, L
    Marjoram, J
    Fitzgerald-Barron, A
    Mant, D
    BRITISH MEDICAL JOURNAL, 2002, 325 (7358): : 258 - 259
  • [38] INTRAOCULAR PRESSURE AND OPHTHALMIC ARTERY PRESSURE REGISTERED WITH DIRECT METHODS
    BORRAS, A
    BIBLIOTHECA OPHTHALMOLOGICA, 1968, (74): : 215 - &
  • [39] Changes in intraocular pressure after intraocular eye surgery-the influence of measuring technique
    Kovacic, Hrvoje
    Wolfs, Roger C. W.
    Kilic, Emine
    Ramdas, Wishal D.
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (06) : 967 - 973
  • [40] Different Methods of Secondary Intraocular Lens Implantation
    Forlini, Matteo
    Malyugin, Boris
    Ahmed, Ike
    Scharioth, Gabor
    Mastropasqua, Rodolfo
    Mularoni, Alessandro
    JOURNAL OF OPHTHALMOLOGY, 2023, 2023