Benefit of simultaneous recording of EEG and MEG in dipole localization

被引:47
|
作者
Yoshinaga, H
Nakahori, T
Ohtsuka, Y
Oka, E
Kitamura, Y
Kiriyama, H
Kinugasa, K
Miyamoto, K
Hoshida, T
机构
[1] Okayama Univ, Sch Med, Dept Child Neurol, Okayama 7008558, Japan
[2] Okayama Ryogo Ctr, Okayama, Japan
[3] Real Neurotechnol Co, Toyama, Japan
[4] Nara Med Univ, Dept Neurosurg, Nara, Japan
关键词
MEG; EEG; localization-related epilepsy; dipole;
D O I
10.1046/j.1528-1157.2002.42901.x
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose: In this study, we tried to show that EEG and magnetoencephalography (MEG) are clinically complementary to each other and that a combination of both technologies is useful for the precise diagnosis of epileptic focus. Methods: We recorded EEGs and MEGs simultaneously and analyzed dipoles in seven patients with intractable localization-related epilepsy. MEG dipoles were analyzed by using a BTI Magnes 148-channel magnetometer. EEG dipoles were analyzed by using a realistically shaped four-layered head model (scalp-skull-fluid-brain) built from 2.0-mm slice magnetic resonance imaging (MRI) images. Results: (a) In two of seven patients, MEG could not detect any epileptiform discharges, whereas EEG showed clear spikes. However, dipoles estimated from the MEG data corresponding to the early phase of EEG spikes clustered at a location close to that of the EEG-detected dipole. (b) In two of seven patients, EEG showed only intermittent high-voltage slow waves (HVSs) without definite spikes. However, MEG showed clear epileptiform discharges preceding these EEG-detected HVSs. Dipoles estimated for these EEG-detected HVSs were located at a location close to that of the MEG-detected dipoles. (c) Based on the agreement of the results of these two techniques, surgical resection was performed in one patient with good results. Conclusions: Dipole modeling of epileptiform activity by MEG and EEG sometimes provides information not obtainable with either modality used alone.
引用
收藏
页码:924 / 928
页数:5
相关论文
共 50 条
  • [21] Simultaneous recording of MEG, EEG and intracerebral EEG during visual stimulation: From feasibility to single-trial analysis
    Dubarry, Anne-Sophie
    Badier, Jean-Michel
    Trebuchon-Da Fonseca, Agnes
    Gavaret, Martine
    Carron, Romain
    Bartolomei, Fabrice
    Liegeois-Chauvel, Catherine
    Regis, Jean
    Chauvel, Patrick
    Alario, F. -Xavier
    Benar, Christian-G.
    NEUROIMAGE, 2014, 99 : 548 - 558
  • [22] EEG dipole source localization
    Cuffin, BN
    IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 1998, 17 (05): : 118 - 122
  • [23] EEG DIPOLE LOCALIZATION - DISCUSSION
    BAUMGARTNER, C
    ACTA NEUROLOGICA SCANDINAVICA, 1994, 89 : 31 - 32
  • [24] A SIMPLE METHOD FOR 3-DIMENSIONAL LOCALIZATION OF EPILEPTIC ACTIVITY RECORDED BY SIMULTANEOUS EEG AND MEG
    SALUSTRI, C
    CHAPMAN, RM
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 73 (06): : 473 - 478
  • [25] Localization techniques for EEG and MEG in children and adolescents
    Brandl, U
    NERVENHEILKUNDE, 1999, 18 (06) : 282 - 286
  • [26] MEG VERSUS EEG LOCALIZATION TEST - REPLY
    COHEN, D
    ANNALS OF NEUROLOGY, 1991, 30 (02) : 223 - 224
  • [27] Coregistered EEG/MEG for source localization in epilepsy
    Stefan, Hermann
    EPILEPSIA, 2010, 51 : 66 - 67
  • [28] Improved Dipole Source Localization from Simultaneous MEG-EEG Data by Combining a Global Optimization Algorithm with a Local Parameter Search: A Brain Phantom Study
    Bastola, Subrat
    Jahromi, Saeed
    Chikara, Rupesh
    Stufflebeam, Steven M.
    Ottensmeyer, Mark P.
    De Novi, Gianluca
    Papadelis, Christos
    Alexandrakis, George
    BIOENGINEERING-BASEL, 2024, 11 (09):
  • [29] Investigations of dipole localization accuracy in MEG using the bootstrap
    Darvas, F
    Rautiainen, M
    Pantazis, D
    Baillet, S
    Benali, H
    Mosher, JC
    Garnero, L
    Leahy, RM
    NEUROIMAGE, 2005, 25 (02) : 355 - 368
  • [30] Statistical performance analysis of signal variance-based dipole models for MEG/EEG source localization and detection
    Rodríguez-Rivera, A
    Van Veen, BD
    Wakai, RT
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (02) : 137 - 149