Comparison of electrochemical property between multiwalled carbon nanotubes and porous graphitized carbon monolith modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid

被引:16
|
作者
Mukdasai, Siriboon [1 ]
Moore, Eric [2 ]
Glennon, Jeremy D. [3 ,4 ]
He, Xiaoyun [5 ]
Nesterenko, Ekaterina P. [5 ]
Nesterenko, Pavel N. [6 ]
Paull, Brett [6 ]
Pravda, Mila [3 ,4 ]
Srijaranai, Supalax [1 ]
机构
[1] Khon Kaen Univ, Fac Sci, Dept Chem, Mat Chem Res Ctr, Khon Kaen 40002, Thailand
[2] Tyndall Natl Inst, Cork, Ireland
[3] Natl Univ Ireland Univ Coll Cork, Dept Chem, Innovat Chromatog Grp, ISSC, Cork, Ireland
[4] Natl Univ Ireland Univ Coll Cork, ABCRF, Cork, Ireland
[5] Dublin City Univ, ISSC, Dublin 9, Ireland
[6] Univ Tasmania, Australian Ctr Res Separat Sci ACROSS, Hobart, Tas 7001, Australia
基金
爱尔兰科学基金会;
关键词
Porous graphitized carbon monolith; Multi-walled carbon nanotubes; Ascorbic acid; Uric acid; Modified glassy carbon electrode; SPECTROPHOTOMETRIC DETERMINATION; DOPAMINE; SENSOR; HPLC;
D O I
10.1016/j.jelechem.2014.07.030
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this work, glassy carbon electrode (GCE) was modified with porous graphitized carbon monolith (CM) as a new nanomaterials and multi-walled carbon nanotubes (MWCNTs) for simultaneous determination of ascorbic acid (AA) and uric acid (UA). Scanning electron microscopy (SEM), electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) were employed for the surface analysis of the modified electrodes. In this simultaneous detection, the electrochemical response of AA and UA on MWCNTs/GCE exhibited broad anodic peaks and were resolved into separated CV peaks at +45 mV and +254 mV, respectively. In comparison, two well resolved peaks of CM/GCE were obtained at -39 mV and +233 mV with flat base-lines for oxidation of AA and UA, respectively. Under the optimum conditions, the performance of porous graphitized carbon monolith were superior to MWCNTs modified glassy carbon electrode. For CM/GCE, the oxidation peak current was linearly dependent on AA and UA concentration in the range 0.195-4.04 mM and 0.094-1.90 mM, with the correlation coefficients (R-2) greater than 0.997. Detection limits (S/N= 3) were found 0.39 u,M and 0.15 mu M for AA and UA, respectively. The recoveries of the AA and UA from spiked human serum were 76.0-94.2%. In addition, the CM/GCE showed high sensitivity, good reproducibility and long-time stability at least 1 month without significant loss of electrochemical signal. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:53 / 59
页数:7
相关论文
共 50 条
  • [1] Electrodeposition of palladium nanoparticles on porous graphitized carbon monolith modified carbon paste electrode for simultaneous enhanced determination of ascorbic acid and uric acid
    Mukdasai, Siriboon
    Crowley, Una
    Pravda, Mila
    He, Xiaoyun
    Nesterenko, Ekaterina P.
    Nesterenko, Pavel N.
    Paull, Brett
    Srijaranai, Supalax
    Glennon, Jeremy D.
    Moore, Eric
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 218 : 280 - 288
  • [2] Synergistic Effect of Graphene and Multiwalled Carbon Nanotubes on a Glassy Carbon Electrode for Simultaneous Determination of Uric Acid and Dopamine in the Presence of Ascorbic Acid
    He, Sijing
    Yu, Yanyan
    Chen, Zuanguang
    Shi, Qiujia
    Zhang, Lin
    ANALYTICAL LETTERS, 2015, 48 (02) : 248 - 258
  • [3] Novel functionalized multiwalled carbon nanotube-glassy carbon electrode for simultaneous determination of ascorbic acid and uric acid
    Rohani, Tahereh
    Taher, Mohammad Ali
    ARABIAN JOURNAL OF CHEMISTRY, 2018, 11 (02) : 214 - 220
  • [4] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Xinying Ma
    Mingyong Chao
    Meifeng Chen
    Russian Journal of Electrochemistry, 2014, 50 : 154 - 161
  • [5] Simultaneous electrochemical determination of uric acid and ascorbic acid on a glassy carbon electrode modified with cobalt(II) tetrakisphenylporphyrin
    Li, CX
    Zeng, YL
    Liu, YJ
    Tang, CR
    ANALYTICAL SCIENCES, 2006, 22 (03) : 393 - 397
  • [6] Simultaneous electrochemical determination of norepinephrine, ascorbic acid and uric acid using a graphene modified glassy carbon electrode
    Ma, Xinying
    Chao, Mingyong
    Chen, Meifeng
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2014, 50 (02) : 154 - 161
  • [7] Simultaneous Electrochemical Determination of Uric Acid and Ascorbic Acid on a Glassy Carbon Electrode Modified with Cobalt(II) Tetrakisphenylporphyrin
    Chun-Xiang Li
    Yun-Long Zeng
    Ying-Ju Liu
    Chun-Rang Tang
    Analytical Sciences, 2006, 22 : 393 - 397
  • [8] Graphene-Multiwalled Carbon Nanotubes Modified Glassy Carbon Electrodes for Simultaneous Detection of Ascorbic Acid, Dopamine, and Uric Acid
    Hsieh, Hsien-Hsu
    Xu, Jie-Yu
    Lin, Jing-Tong
    Chiang, Yun-Ting
    Weng, Yu-Ching
    ACS OMEGA, 2025, 10 (08): : 8160 - 8171
  • [9] Norepinephrine-modified glassy carbon electrode for the simultaneous determination of ascorbic acid and uric acid
    Zare, HR
    Memarzadeh, F
    Mazloum-Ardakani, M
    Namazian, M
    Golabi, SM
    ELECTROCHIMICA ACTA, 2005, 50 (16-17) : 3495 - 3502
  • [10] Simultaneous electrochemical determination of uric acid, dopamine, and ascorbic acid at single-walled carbon nanohorn modified glassy carbon electrode
    Zhu, Shuyun
    Li, Haijuan
    Niu, Wenxin
    Xu, Guobao
    BIOSENSORS & BIOELECTRONICS, 2009, 25 (04): : 940 - 943