Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates

被引:15
|
作者
Riedel, Stefan [1 ]
Junkins, Alan [2 ]
Stamper, Paul D.
Cress, Gretchen [3 ]
Widness, John A. [3 ]
Doern, Gary V. [2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Div Microbiol,Johns Hopkins Bayview Med Ctr, Baltimore, MD 21224 USA
[2] Univ Iowa, Dept Pathol, Div Microbiol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Pediat, Div Neonatol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
AUTOLOGOUS BLOOD; UNITED-STATES; CONTAMINATION; COLLECTION; TRANSPLANTATION; STERILITY; PRODUCTS; THERAPY; STORAGE; SAFETY;
D O I
10.1128/JCM.00302-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system (P < 0.001). When concentrated red cells and whole blood were compared, the Bactec system detected bacterial growth consistently sooner than the BacT/Alert system in all seeded bacteria except Staphylococcus species in whole blood. The median lengths of time to detection (LTD) for whole blood and concentrated cells in BacT/Alert were 18.7 h and 18.5 h, respectively. The median LTD for the same blood fractions using the Bactec system were 16.05 h and 15.64 h. These differences in LTD by blood culture system and sample type were statistically significant (whole blood, P = 0.0449; concentrated cells, P = 0.0037). Based on the results of our study, we recommend the use of either concentrated red cells or whole blood for sterility testing in UCB samples. In our laboratory, the Bactec system compared to the BacT/Alert system was the superior method for rapid detection of bacterial contaminants in cord blood.
引用
收藏
页码:1645 / 1649
页数:5
相关论文
共 50 条
  • [31] Time-to-Detection Comparison for a Novel Blood Culture System Using Simulated Blood Cultures: DL™ versus BacT/ALERT™ and BACTEC™
    Demiray, Tayfur
    Koroglu, Mehmet
    Altindis, Mustafa
    CLINICAL LABORATORY, 2016, 62 (09) : 1595 - 1600
  • [32] Time-to-detection of bacteria and yeast with the BACTEC FX versus BacT/Alert Virtuo blood culture systems
    Somily, Ali Mohammed
    Babay, Hanan Ahmed Habib
    Torchyan, Armen Albert
    Sayyed, Samina B.
    Absar, Muhammed
    Al-Aqeel, Rima
    Binkhamis, Khalifa
    ANNALS OF SAUDI MEDICINE, 2018, 38 (03) : 194 - 199
  • [33] EVALUATION OF ROUTINE ANAEROBIC BLOOD CULTURES IN THE BACT/ALERT BLOOD CULTURE SYSTEM
    BANNISTER, ER
    WOODS, GL
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1995, 104 (03) : 279 - 282
  • [34] Bactec 9240: Impact of seeded volume on blood culture results
    Ygout, JF
    LeBouquin, C
    Ungeheuer, MN
    Lanson, B
    PATHOLOGIE BIOLOGIE, 1996, 44 (04): : 307 - 311
  • [35] The diagnosis of brucellosis by use of BACTEC 9240 blood culture system
    Ozturk, R
    Mert, A
    Kocak, F
    Ozaras, R
    Koksal, F
    Tabak, F
    Bilir, M
    Aktuglu, Y
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 44 (02) : 133 - 135
  • [36] Bactec 9240 blood culture system:: to preincubate at 35 °C or not?
    Lemming, L
    Holt, HM
    Petersen, IS
    Ostergaard, C
    Bruun, B
    CLINICAL MICROBIOLOGY AND INFECTION, 2004, 10 (12) : 1089 - 1091
  • [37] Controlled Clinical Comparison of BacT/Alert FA Plus and FN Plus Blood Culture Media with BacT/Alert FA and FN Blood Culture Media
    Kirn, T. J.
    Mirrett, S.
    Reller, L. B.
    Weinstein, M. P.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2014, 52 (03) : 839 - 843
  • [38] Comparison of BACTEC PLUS blood culture media to BacT/Alert FA blood culture media for detection of bacterial pathogens in samples containing therapeutic levels of antibiotics
    Flayhart, Diane
    Borek, Anita P.
    Wakefield, Teresa
    Dick, James
    Carroll, Karen C.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2007, 45 (03) : 816 - 821
  • [39] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples (vol 10, 221, 2019)
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Liliana
    Posteraro, Brunella
    Sabbatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [40] COMPARISON OF SENTINEL AND BACTEC BLOOD CULTURE SYSTEMS
    STEVENS, M
    PATEL, H
    WALTERS, A
    BURCH, K
    JAY, A
    DOWLING, N
    MITCHELL, CJ
    SWANN, RA
    WILLIS, AT
    SHANSON, DC
    MACDONALD, CA
    JOURNAL OF CLINICAL PATHOLOGY, 1992, 45 (09) : 815 - 818