Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates

被引:15
|
作者
Riedel, Stefan [1 ]
Junkins, Alan [2 ]
Stamper, Paul D.
Cress, Gretchen [3 ]
Widness, John A. [3 ]
Doern, Gary V. [2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Div Microbiol,Johns Hopkins Bayview Med Ctr, Baltimore, MD 21224 USA
[2] Univ Iowa, Dept Pathol, Div Microbiol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Pediat, Div Neonatol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
AUTOLOGOUS BLOOD; UNITED-STATES; CONTAMINATION; COLLECTION; TRANSPLANTATION; STERILITY; PRODUCTS; THERAPY; STORAGE; SAFETY;
D O I
10.1128/JCM.00302-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system (P < 0.001). When concentrated red cells and whole blood were compared, the Bactec system detected bacterial growth consistently sooner than the BacT/Alert system in all seeded bacteria except Staphylococcus species in whole blood. The median lengths of time to detection (LTD) for whole blood and concentrated cells in BacT/Alert were 18.7 h and 18.5 h, respectively. The median LTD for the same blood fractions using the Bactec system were 16.05 h and 15.64 h. These differences in LTD by blood culture system and sample type were statistically significant (whole blood, P = 0.0449; concentrated cells, P = 0.0037). Based on the results of our study, we recommend the use of either concentrated red cells or whole blood for sterility testing in UCB samples. In our laboratory, the Bactec system compared to the BacT/Alert system was the superior method for rapid detection of bacterial contaminants in cord blood.
引用
收藏
页码:1645 / 1649
页数:5
相关论文
共 50 条
  • [21] Comparative evaluation of BacT/ALERT VIRTUO and BACTEC FX400 blood culture systems for the detection of bloodstream infections
    Qin, Yurong
    Liao, Yiwen
    Zhou, Jingfang
    Liu, Weijiang
    Chen, Huimin
    Chen, Xiaoli
    Wang, Weisha
    Zhang, Ni
    Zhao, Yunhu
    Wang, Liang
    Gu, Bing
    Liu, Suling
    MICROBIOLOGY SPECTRUM, 2025, 13 (01)
  • [22] Evaluation of BACTEC™ FX and BacT/Alert™ Automated Blood Culture Systems for Detection of Clinically Relevant Bacterial and Yeast Species
    Absar, Muhammad
    Alshahrani, Ibraheem
    Nashmy, Fahd
    Salami, Mosa
    Hadadi, Ali
    AlMarzooq, Aous
    AlAsiri, Alhussain
    AlRashidi, Abdulaziz
    AlFaifi, Mohammed
    ADVANCEMENTS IN LIFE SCIENCES, 2024, 11 (03): : 648 - 654
  • [23] Clinical evaluation of the BacT/Alert and isolator aerobic blood culture systems
    Engler, HD
    Fahle, GA
    Gill, VJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1996, 105 (06) : 774 - 781
  • [24] In vitro Evaluation of BACT/ALERT® VIRTUO®, BACT/ALERT 3D®, and BACTEC™ FX Automated Blood Culture Systems for Detection of Microbial Pathogens Using Simulated Human Blood Samples
    Menchinelli, Giulia
    Liotti, Flora Marzia
    Fiori, Barbara
    De Angelis, Giulia
    D'Inzeo, Tiziana
    Giordano, Lilian
    Posteraro, Brunella
    Sabatucci, Michela
    Sanguinetti, Maurizio
    Spanu, Teresa
    FRONTIERS IN MICROBIOLOGY, 2019, 10
  • [25] Evaluation of BACTEC 9240 blood culture system by using the aerobic 9240 medium for fungemia detection
    FrickerHidalgo, H
    ChirpazCerbat, A
    Lebeau, B
    AmbroiseThomas, P
    Grillot, R
    JOURNAL DE MYCOLOGIE MEDICALE, 1997, 7 (03): : 128 - 133
  • [26] COMPARISON OF BACT/ALERT WITH SIGNAL BLOOD CULTURE SYSTEM
    ROHNER, P
    PEPEY, B
    AUCKENTHALER, R
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (02) : 313 - 317
  • [27] BacT/Alert and isolator blood culture systems - Reply
    Engler, HD
    Fahle, GA
    Gill, VJ
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1997, 107 (03) : 377 - 378
  • [28] Comparison of Growth Performance of the BacT/ALERT VIRTUO and BACTEC FX Blood Culture Systems Under Simulated Bloodstream Infection Conditions
    Park, Joonhong
    Han, Seounghwan
    Shin, Soyoung
    CLINICAL LABORATORY, 2017, 63 (01) : 39 - 46
  • [29] Comparison of Clinical Performance Between BacT/Alert Virtuo and BacT/Alert 3D Blood Culture Systems
    Kim, Seong Chun
    Lee, Seungjun
    Kim, Sunjoo
    Cho, Oh-Hyun
    Park, Hyunwoong
    Yu, Seong-Mi
    ANNALS OF LABORATORY MEDICINE, 2019, 39 (03) : 237 - 242
  • [30] Controlled comparison of BacT/ALERT FAN aerobic medium and BACTEC fungal blood culture medium for detection of fungemia
    McDonald, LC
    Weinstein, MP
    Fune, J
    Mirrett, S
    Reimer, LG
    Reller, LB
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (02) : 622 - 624