Comparison of the Bactec 9240 and BacT/Alert Blood Culture Systems for Evaluation of Placental Cord Blood for Transfusion in Neonates

被引:15
|
作者
Riedel, Stefan [1 ]
Junkins, Alan [2 ]
Stamper, Paul D.
Cress, Gretchen [3 ]
Widness, John A. [3 ]
Doern, Gary V. [2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Pathol, Div Microbiol,Johns Hopkins Bayview Med Ctr, Baltimore, MD 21224 USA
[2] Univ Iowa, Dept Pathol, Div Microbiol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
[3] Univ Iowa, Dept Pediat, Div Neonatol, Roy J & Lucille A Carver Coll Med, Iowa City, IA 52242 USA
基金
美国国家卫生研究院;
关键词
AUTOLOGOUS BLOOD; UNITED-STATES; CONTAMINATION; COLLECTION; TRANSPLANTATION; STERILITY; PRODUCTS; THERAPY; STORAGE; SAFETY;
D O I
10.1128/JCM.00302-09
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The Bactec 9240 and the BacT/Alert blood culture systems were compared as a means for detection of bacterial contaminants in whole blood, concentrated red cells, and plasma preparations prepared from umbilical cord blood (UCB) samples. Ninety-two UCB units seeded with low levels of various bacteria were evaluated. In more than 50% of cases, growth was not detected in plasma using either system (P < 0.001). When concentrated red cells and whole blood were compared, the Bactec system detected bacterial growth consistently sooner than the BacT/Alert system in all seeded bacteria except Staphylococcus species in whole blood. The median lengths of time to detection (LTD) for whole blood and concentrated cells in BacT/Alert were 18.7 h and 18.5 h, respectively. The median LTD for the same blood fractions using the Bactec system were 16.05 h and 15.64 h. These differences in LTD by blood culture system and sample type were statistically significant (whole blood, P = 0.0449; concentrated cells, P = 0.0037). Based on the results of our study, we recommend the use of either concentrated red cells or whole blood for sterility testing in UCB samples. In our laboratory, the Bactec system compared to the BacT/Alert system was the superior method for rapid detection of bacterial contaminants in cord blood.
引用
收藏
页码:1645 / 1649
页数:5
相关论文
共 50 条
  • [1] COMPARISON OF BACTEC-9240 AND BACT/ALERT BLOOD CULTURE SYSTEMS IN AN ADULT HOSPITAL
    SMITH, JA
    BRYCE, EA
    NGUIYEN, JH
    ROBERTS, FJ
    JOURNAL OF CLINICAL MICROBIOLOGY, 1995, 33 (07) : 1905 - 1908
  • [2] Comparison of the BACTEC 9240 and BacT/Alert blood culture systems for detection of bacterial contamination in platelet concentrates
    Riedel, Stefan
    Siwek, Gregory
    Beekmann, Susan E.
    Richter, Sandra S.
    Raife, Thomas
    Doern, Gary V.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (06) : 2262 - 2264
  • [3] Comparison of BACTEC 9240 and BacT/Alert Blood Culture Systems for Detection of Microbiological Contamination in Platelet Concentrates
    Givisiez, F. N.
    Cioffi, J. M.
    Basques, F. V.
    Santos, V. A.
    Rezende, G. C.
    Silva, R. M.
    Ferreira, A. M.
    Paiva, L. F.
    Oliveira, L. T.
    Tardelli, A. C.
    TRANSFUSION, 2014, 54 : 206A - 206A
  • [4] Use of simulated blood cultures for time to detection comparison between BacT/ALERT™ and BACTEC™ 9240 blood culture systems
    FrancescoViganò, E
    Vasconi, E
    Agrappi, C
    Clerici, P
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2002, 44 (03) : 235 - 240
  • [5] Evaluation of the BacT/ALERT and BACTEC 9240 automated blood culture systems for growth time of Brucella species in a Turkish tertiary hospital
    Baysallar, Mehmet
    Aydogan, Hakan
    Kilic, Abdullah
    Kucukkaraaslan, Ayten
    Senses, Zeynep
    Doganci, Levent
    MEDICAL SCIENCE MONITOR, 2006, 12 (07): : BR235 - BR238
  • [6] Multicenter comparison of BACTEC 9050 and BACTEC 9240 blood culture systems
    Murray, PR
    Hollick, GE
    Jerris, RC
    Wilson, ML
    JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (06) : 1601 - 1603
  • [7] Direct comparison of the BACTEC 9240 and BacT/ALERT 3D automated blood culture systems for Candida growth detection
    Horvath, LL
    George, BJ
    Murray, CK
    Harrison, LS
    Hospenthal, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) : 115 - 118
  • [8] Comparison of the effect of delayed entry into 2 different blood culture systems (BACTEC 9240 and BacT/ALERT 3D) on culture positivity
    Akan, ÖA
    Yildiz, E
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2006, 54 (03) : 193 - 196
  • [9] Epidemiology of bloodstream infections and time to detection of positive blood cultures: An evaluation of the automated BacT/Alert and BACTEC 9240 systems
    Endimiani, A
    Tamborini, A
    Luzzaro, F
    Lombardi, G
    Toniolo, A
    MICROBIOLOGICA, 2002, 25 (01): : 9 - 16
  • [10] Comparison of the two blood culture systems, Bactec 9240 and BacT/Alert 3D, in the detection of Candida spp. and bacteria with polymicrobial sepsis
    Klingspor, L.
    Muhammed, S. A.
    Ozenci, V.
    EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 2012, 31 (11) : 2983 - 2987