Automatic anatomy recognition in whole-body PET/CT images

被引:18
|
作者
Wang, Huiqian [1 ,2 ]
Udupa, Jayaram K. [2 ]
Odhner, Dewey [2 ]
Tong, Yubing [2 ]
Zhao, Liming [2 ,3 ]
Torigian, Drew A. [2 ]
机构
[1] Chongqing Univ, Coll Optoelect Engn, Chongqing 400044, Peoples R China
[2] Univ Penn, Dept Radiol, Med Image Proc Grp, Philadelphia, PA 19104 USA
[3] Chongqing Univ Posts & Telecommun, Res Ctr Intelligent Syst & Robot, Chongqing 400065, Peoples R China
关键词
image segmentation; PET/CT imaging; object recognition; texture; fuzzy models; POSITRON-EMISSION-TOMOGRAPHY; 3D CT IMAGES; THRESHOLD SEGMENTATION; REGRESSION FORESTS; NECK-CANCER; LOCALIZATION; HEAD; CLASSIFICATION; DELINEATION; SYSTEM;
D O I
10.1118/1.4939127
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Whole-body positron emission tomography/computed tomography (PET/CT) has become a standard method of imaging patients with various disease conditions, especially cancer. Body-wide accurate quantification of disease burden in PET/CT images is important for characterizing lesions, staging disease, prognosticating patient outcome, planning treatment, and evaluating disease response to therapeutic interventions. However, body-wide anatomy recognition in PET/CT is a critical first step for accurately and automatically quantifying disease body-wide, body-region-wise, and organwise. This latter process, however, has remained a challenge due to the lower quality of the anatomic information portrayed in the CT component of this imaging modality and the paucity of anatomic details in the PET component. In this paper, the authors demonstrate the adaptation of a recently developed automatic anatomy recognition (AAR) methodology [Udupa et al., "Body-wide hierarchical fuzzy modeling, recognition, and delineation of anatomy in medical images," Med. Image Anal. 18, 752-771 (2014)] to PET/CT images. Their goal was to test what level of object localization accuracy can be achieved on PET/CT compared to that achieved on diagnostic CT images. Methods: The authors advance the AAR approach in this work in three fronts: (i) from body-region-wise treatment in the work of Udupa et al. to whole body; (ii) from the use of image intensity in optimal object recognition in the work of Udupa et al. to intensity plus object-specific texture properties, and (iii) from the intramodality model-building-recognition strategy to the intermodality approach. The whole-body approach allows consideration of relationships among objects in different body regions, which was previously not possible. Consideration of object texture allows generalizing the previous optimal threshold-based fuzzy model recognition method from intensity images to any derived fuzzy membership image, and in the process, to bring performance to the level achieved on diagnostic CT and MR images in body-region-wise approaches. The intermodality approach fosters the use of already existing fuzzy models, previously created from diagnostic CT images, on PET/CT and other derived images, thus truly separating the modality-independent object assembly anatomy from modality-specific tissue property portrayal in the image. Results: Key ways of combining the above three basic ideas lead them to 15 different strategies for recognizing objects in PET/CT images. Utilizing 50 diagnostic CT image data sets from the thoracic and abdominal body regions and 16 whole-body PET/CT image data sets, the authors compare the recognition performance among these 15 strategies on 18 objects from the thorax, abdomen, and pelvis in object localization error and size estimation error. Particularly on texture membership images, object localization is within three voxels on whole-body low-dose CT images and 2 voxels on body-region-wise low-dose images of known true locations. Surprisingly, even on direct body-region-wise PET images, localization error within 3 voxels seems possible. Conclusions: The previous body-region-wise approach can be extended to whole-body torso with similar object localization performance. Combined use of image texture and intensity property yields the best object localization accuracy. In both body-region-wise and whole-body approaches, recognition performance on low-dose CT images reaches levels previously achieved on diagnostic CT images. The best object recognition strategy varies among objects; the proposed framework however allows employing a strategy that is optimal for each object. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:613 / 629
页数:17
相关论文
共 50 条
  • [41] Absorbed whole-body doses from whole-body CT scan examinations: can the observations relating to screening of healthy individuals be extrapolated to the use of whole-body CT in PET/CT hybrid machines?
    Nair, N
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (10) : 1242 - 1242
  • [42] A Novel Fusion Framework Based on Adaptive PCNN in NSCT Domain for Whole-Body PET and CT Images
    Song, Zhiying
    Jiang, Huiyan
    Li, Siqi
    COMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE, 2017, 2017
  • [43] JOURNAL CLUB: CT Dose Optimization for Whole-Body PET/CT Examinations
    Tonkopi, Elena
    Ross, Andrew A.
    MacDonald, Anita
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : 257 - 263
  • [44] Automated Liver Segmentation for Whole-Body Low-Contrast CT Images from PET-CT Scanners
    Wang, Xiuying
    Li, Changyang
    Eberl, Stefan
    Fulham, Michael
    Feng, Dagan
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3565 - 3568
  • [45] Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
    Jallow, Ngoneh
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John M.
    Nye, Jonathon A.
    JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (02) : 238 - 241
  • [46] Whole-body 18FDG-PET/CT or whole-body gadolinium-enhanced MRI for distant staging?
    Bacigalupo, L.
    Groheux, D.
    Hindie, E.
    ANNALS OF ONCOLOGY, 2013, 24 (01) : 9 - 13
  • [47] Semi-automatic segmentation of whole-body images in longitudinal studies
    Grossiord, Eloise
    Risser, Laurent
    Kanoun, Salim
    Aziza, Richard
    Chiron, Harold
    Ysebaert, Loic
    Malgouyres, Francois
    Ken, Soleakhena
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2021, 7 (01)
  • [48] 18F-FDG PET/CT of Patients With Cancer: Comparison of Whole-Body and Limited Whole-Body Technique
    Osman, Medhat M.
    Chaar, Bassem T.
    Muzaffar, Razi
    Oliver, Dana
    Reimers, Hans Joachim
    Walz, Bruce
    Nguyen, Nghi C.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (06) : 1397 - 1403
  • [49] Comparison of the diagnostic value of whole-body DWI, 18F-FDG PET/CT and whole-body CT in metastatic breast cancer
    Gelezhe, Pavel
    Morozov, Sergey
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [50] Automatic nonrigid registration of whole body CT mice images
    Li, Xia
    Yankeelov, Thomas E.
    Peterson, Todd E.
    Gore, John C.
    Dawant, Benoit M.
    MEDICAL PHYSICS, 2008, 35 (04) : 1507 - 1520