LONG-TERM FADE STUDY OF THE DT-702 LiF: Mg,Cu,P TLD

被引:4
|
作者
Delzer, J. A. [1 ]
Hawley, J. R. [1 ]
Romanyukha, A. [2 ]
Nemmers, S. [1 ]
Selwyn, R. [2 ]
Benevides, L. A. [2 ]
机构
[1] Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
[2] USN, Dosimetry Ctr, Bethesda, MD 20889 USA
关键词
D O I
10.1093/rpd/ncn182
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
LiF thermoluminescent dosemeters (TLDs) are used by the US Navy to record radiation exposure of personnel. The Model DT-648 LiF: Mg,Ti TLD has been replaced by a new Model DT-702 LiF: Mg,Cu,P TLD. The DT-648 was used for many years and has undergone extensive testing to identify its pre- and post-irradiation fade operating characteristics. Studies have shown that the addition of copper increases the thermoluminesence sensitivity of the TLD for improved low-level radiation monitoring. This study evaluates various fading characteristics of the new copper-doped dosemeter using current equipment for processing of TLDs and calibrating to a National Institute of Standards and Technology standard source. The 57-week study took place at the Naval Dosimetry Center, Bethesda, MD, USA. TLDs were stored for various lengths of time before and after being exposed to a National Institute of Standards and Technology calibrated radiation sources. TLDs were then processed using current US Navy instructions and the resulting dose compared with the calibrated exposure. Both loss of signal and loss of sensitivity were evaluated. The results of this study have shown that the DT-702 TLD has no statistically significant change in sensitivity or change in signal with up to 57 weeks of pre- or post-irradiation time. The results of this study will increase the accuracy of exposure record keeping for the Navy and will allow longer issue periods. This will increase flexibility with international and domestic shipping procedures, as well as reduce workload requirements for dosimetry processing.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [41] ESR study of phosphorus-related defects in irradiated LiF:Mg,Cu,P and related phosphors
    Gundurao, T. K.
    Moharil, S. V.
    RADIATION MEASUREMENTS, 2007, 42 (01) : 35 - 42
  • [42] Electron energy loss spectroscopy (EELS) study of thermal effects in LiF:Mg,Cu,P phosphors
    Chen, T.-C.
    Qian, M.
    Stoebe, T.G.
    Journal of Physics Condensed Matter, 11 (29):
  • [43] LONG-TERM STUDY OF ORAL CONTRACEPTION WITH NORETHINDRONE 2 MG AND MESTRANOL 0.1 MG
    HUTCHERSON, WP
    SCHWARTZ, HA
    WEATHERS, W
    FERTILITY AND STERILITY, 1966, 17 (01) : 59 - +
  • [44] THERMO-LUMINESCENCE RESPONSE OF LIF-MG,CU,P AND LIF TLD-100 TO THERMAL-NEUTRONS, AM-241 ALPHA-RAYS AND GAMMA-RAYS
    PRADHAN, AS
    BHATT, RC
    RADIATION PROTECTION DOSIMETRY, 1989, 27 (03) : 185 - 188
  • [45] Study of a new Lif:Mg,Cu,P formulation with enhanced thermal stability and a lower residual TL signal
    Tang, K.
    Cui, H.
    Zhu, H.
    Fan, Q.
    RADIATION MEASUREMENTS, 2007, 42 (01) : 24 - 28
  • [46] Miniature LiF:Mg,Cu,P TLDs to study the effect of applicator material in 192-Ir brachytherapy
    Hood C.
    Duggan L.
    Bazley S.
    Denham J.
    Kron T.
    Australasian Physics & Engineering Sciences in Medicine, 2006, 29 (4): : 300 - 302
  • [47] Study on the influence of thermal treatments on the radio-luminescence in LiF:Mg,Cu,P (GR-200A)
    Tang, Kaiyong
    RADIATION MEASUREMENTS, 2021, 148 (148)
  • [48] Study of long-term stability of Mo-Cu bilayer films
    Wang, Yeru
    Wang, Sifan
    Ding, Jiao
    Chen, Yanling
    Cui, Wei
    Huang, Rui
    Li, Chengzhe
    Li, Fajun
    Liang, Yajie
    Jin, Hai
    Wang, Guole
    Zhang, Yuning
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2022, 35 (09):
  • [49] Further study on the influence of thermal treatments on the glow curve structure in LiF:Mg,Cu,P (GR-200A)
    Tang, K.
    Fan, H.
    Cui, H.
    Zhu, H.
    Liu, Z.
    RADIATION MEASUREMENTS, 2014, 63 : 1 - 5
  • [50] DAMAGE EFFECTS AND RECOVERY IN LIF-MG, TI THERMOLUMINESCENT DOSIMETERS AFTER LONG-TERM ANNEALING AT 400DEGREESC
    PIESCH, E
    BURGKHARDT, B
    HOFMANN, I
    NUCLEAR INSTRUMENTS & METHODS, 1976, 138 (01): : 157 - 163