LONG-TERM FADE STUDY OF THE DT-702 LiF: Mg,Cu,P TLD

被引:4
|
作者
Delzer, J. A. [1 ]
Hawley, J. R. [1 ]
Romanyukha, A. [2 ]
Nemmers, S. [1 ]
Selwyn, R. [2 ]
Benevides, L. A. [2 ]
机构
[1] Uniformed Serv Univ Hlth Sci, Bethesda, MD 20814 USA
[2] USN, Dosimetry Ctr, Bethesda, MD 20889 USA
关键词
D O I
10.1093/rpd/ncn182
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
LiF thermoluminescent dosemeters (TLDs) are used by the US Navy to record radiation exposure of personnel. The Model DT-648 LiF: Mg,Ti TLD has been replaced by a new Model DT-702 LiF: Mg,Cu,P TLD. The DT-648 was used for many years and has undergone extensive testing to identify its pre- and post-irradiation fade operating characteristics. Studies have shown that the addition of copper increases the thermoluminesence sensitivity of the TLD for improved low-level radiation monitoring. This study evaluates various fading characteristics of the new copper-doped dosemeter using current equipment for processing of TLDs and calibrating to a National Institute of Standards and Technology standard source. The 57-week study took place at the Naval Dosimetry Center, Bethesda, MD, USA. TLDs were stored for various lengths of time before and after being exposed to a National Institute of Standards and Technology calibrated radiation sources. TLDs were then processed using current US Navy instructions and the resulting dose compared with the calibrated exposure. Both loss of signal and loss of sensitivity were evaluated. The results of this study have shown that the DT-702 TLD has no statistically significant change in sensitivity or change in signal with up to 57 weeks of pre- or post-irradiation time. The results of this study will increase the accuracy of exposure record keeping for the Navy and will allow longer issue periods. This will increase flexibility with international and domestic shipping procedures, as well as reduce workload requirements for dosimetry processing.
引用
收藏
页码:279 / 286
页数:8
相关论文
共 50 条
  • [21] Effect of TLD-700H (LiF: Mg, Cu, P) sensitivity loss at multiple read-irradiation cycles on TLD reader calibration
    Voss, Shannon P.
    Sucheta, Artur
    Romanyukha, Alex
    Moscovitch, Marco
    Kennemur, Lisa K.
    Benevides, Luis A.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1590 - 1594
  • [22] The Thermoluminescence Study Of Epoxy Based LiF:Mg,Cu,P Dosimeters
    Rahangdale, S. R.
    Wankhede, S. P.
    Kadam, Sonal
    Dhabekar, Bhushan. S.
    Palikundwar, U. A.
    Moharil, S. V.
    INTERNATIONAL CONFERENCE ON CONDENSED MATTER AND APPLIED PHYSICS (ICC 2015), 2016, 1728
  • [23] Effect of neutron irradiation on dosimetric properties of TLD-600H (6LiF:Mg,Cu,P)
    Romanyukha, A.
    Minniti, R.
    Moscovitch, M.
    Thompson, A. K.
    Trompier, F.
    Colle, R.
    Sucheta, A.
    Voss, S. P.
    Benevides, L. A.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1426 - 1431
  • [24] A study on annealing technique for Lif:Mg,Cu,P thermoluminescent dosimeter
    Tsai, W. C.
    Jiang, S. H.
    RADIATION MEASUREMENTS, 2011, 46 (12) : 1595 - 1597
  • [25] Dosimetric properties and stability of thermoluminescent foils made from LiF:Mg,Cu,P or CaSO4:Dy during long-term use
    Klosowski, M.
    Liszka, M.
    Kopec, R.
    Bilski, P.
    Kedzierska, D.
    RADIATION PHYSICS AND CHEMISTRY, 2014, 104 : 212 - 215
  • [26] Effect of ion bombardment on the Tl-response of both LiF (TLD-100) and a home-made LiF:Mg,Cu,P phosphors
    AbdelHamid, HM
    Hussein, MA
    AbouZeid, HM
    Morsy, SM
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 132 (01): : 119 - 122
  • [27] THE ENVIRONMENTAL MONITORING OF THE NATURAL RADIATION BACKGROUND IN ANTARCTICA WITH LIF-MG,CU,P TLD AND X-GAMMA RADIOMETRY
    CAI, G
    GENG, K
    WANG, Q
    RADIATION PROTECTION DOSIMETRY, 1995, 60 (03) : 259 - 262
  • [28] Thermoluminescence of LiF:Mg,Cu,P (GR-200A) TLD after annealing between 200 and 400 degrees C
    Cai, GG
    Fesquet, J
    Dusseau, L
    Martini, M
    Meinardi, F
    Huang, BL
    Tang, KY
    Beteille, D
    Gasiot, J
    RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) : 163 - 166
  • [30] Application of LiF:Mg,Cu,P (MCP-N) thermoluminescent detectors (TLD) for experimental verification of radial dose distribution models
    Gieszczyk, Wojciech
    Olko, Pawel
    Bilski, Pawel
    Grzanka, Leszek
    Obryk, Barbara
    Horwacik, Tomasz
    NUKLEONIKA, 2012, 57 (04) : 507 - 512