Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea

被引:61
|
作者
Scebba, Gaetano [1 ]
Poian, Giulia [1 ]
Karlen, Walter [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Mobile Hlth Syst Lab, Inst Robot & Intelligent Syst, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Cameras; Finite impulse response filters; Monitoring; Estimation; Modulation; Lung; Electrocardiography; Respiratory rate; apnea; non-contact physiological monitoring; nearables; multispectral fusion; thermal imaging; MOTION; ECG;
D O I
10.1109/TBME.2020.2993649
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous monitoring of respiratory activity is desirable in many clinical applications to detect respiratory events. Non-contact monitoring of respiration can be achieved with near- and far-infrared spectrum cameras. However, current technologies are not sufficiently robust to be used in clinical applications. For example, they fail to estimate an accurate respiratory rate (RR) during apnea. We present a novel algorithm based on multispectral data fusion that aims at estimating RR also during apnea. The algorithm independently addresses the RR estimation and apnea detection tasks. Respiratory information is extracted from multiple sources and fed into an RR estimator and an apnea detector whose results are fused into a final respiratory activity estimation. We evaluated the system retrospectively using data from 30 healthy adults who performed diverse controlled breathing tasks while lying supine in a dark room and reproduced central and obstructive apneic events. Combining multiple respiratory information from multispectral cameras improved the root mean square error (RMSE) accuracy of the RR estimation from up to 4.64 monospectral data down to 1.60 breaths/min. The median F1 scores for classifying obstructive (0.75 to 0.86) and central apnea (0.75 to 0.93) also improved. Furthermore, the independent consideration of apnea detection led to a more robust system (RMSE of 4.44 vs. 7.96 breaths/min). Our findings may represent a step towards the use of cameras for vital sign monitoring in medical applications.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 50 条
  • [41] Life detection and non-contact respiratory rate measurement in cluttered environments
    Li, Shiqi
    Wang, Haipeng
    Wang, Shuze
    Zhang, Shuai
    MULTIMEDIA TOOLS AND APPLICATIONS, 2020, 79 (43-44) : 32065 - 32077
  • [42] Non-contact Respiratory Monitoring of Subjects with Sleep-Disordered Breathing
    Tataraidze, Alexander B.
    Anishchenko, Lesya N.
    Korostovtseva, Lyudmila S.
    Bochkarev, Mikhail V.
    Sviryaev, Yurii V.
    2018 IEEE INTERNATIONAL CONFERENCE QUALITY MANAGEMENT, TRANSPORT AND INFORMATION SECURITY, INFORMATION TECHNOLOGIES (IT&QM&IS), 2018, : 736 - 738
  • [43] A Non-Contact Vision-Based System for Respiratory Rate Estimation
    Li, Michael H.
    Yadollahi, Azadeh
    Taati, Babak
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 2119 - 2122
  • [44] NON-CONTACT ECG MONITORING
    Smirnov, Alexey S.
    Erlikh, Vadim V.
    Kodkin, Vladimir L.
    Keller, Andrei V.
    Epishev, Vitaly V.
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [45] Non-contact ECG monitoring
    Brydon, J
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2002, 13 (04) : 641 - 641
  • [46] Life detection and non-contact respiratory rate measurement in cluttered environments
    Shiqi Li
    Haipeng Wang
    Shuze Wang
    Shuai Zhang
    Multimedia Tools and Applications, 2020, 79 : 32065 - 32077
  • [47] Non-contact Apnea-Hypopnea Index Estimation using Near Infrared Video
    Zhu, Kaiyin
    Yadollahi, Azadeh
    Taati, Babak
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 792 - 795
  • [48] Second Harmonic Weighted Reconstruction for Non-Contact Monitoring Heart Rate
    Zheng, Pengwei
    Zheng, Chundi
    Li, Xiaoxia
    Chen, Huihui
    Wang, Aiguo
    Luo, Yihong
    IEEE SENSORS JOURNAL, 2022, 22 (06) : 5815 - 5823
  • [49] Non-contact Heart Rate Monitoring Using Multiple RGB Cameras
    Ghanadian, Hamideh
    Al Osman, Hussein
    COMPUTER ANALYSIS OF IMAGES AND PATTERNS, CAIP 2019, PT II, 2019, 11679 : 85 - 95
  • [50] Non-Contact Heart Rate Monitoring Using Lab Color Space
    Rahman, Hamidur
    Ahmed, Mobyen Uddin
    Begum, Shahina
    PHEALTH 2016, 2016, 224 : 46 - 53