Multispectral Video Fusion for Non-Contact Monitoring of Respiratory Rate and Apnea

被引:61
|
作者
Scebba, Gaetano [1 ]
Poian, Giulia [1 ]
Karlen, Walter [1 ]
机构
[1] Swiss Fed Inst Technol, Dept Hlth Sci & Technol, Mobile Hlth Syst Lab, Inst Robot & Intelligent Syst, Zurich, Switzerland
基金
瑞士国家科学基金会;
关键词
Cameras; Finite impulse response filters; Monitoring; Estimation; Modulation; Lung; Electrocardiography; Respiratory rate; apnea; non-contact physiological monitoring; nearables; multispectral fusion; thermal imaging; MOTION; ECG;
D O I
10.1109/TBME.2020.2993649
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Continuous monitoring of respiratory activity is desirable in many clinical applications to detect respiratory events. Non-contact monitoring of respiration can be achieved with near- and far-infrared spectrum cameras. However, current technologies are not sufficiently robust to be used in clinical applications. For example, they fail to estimate an accurate respiratory rate (RR) during apnea. We present a novel algorithm based on multispectral data fusion that aims at estimating RR also during apnea. The algorithm independently addresses the RR estimation and apnea detection tasks. Respiratory information is extracted from multiple sources and fed into an RR estimator and an apnea detector whose results are fused into a final respiratory activity estimation. We evaluated the system retrospectively using data from 30 healthy adults who performed diverse controlled breathing tasks while lying supine in a dark room and reproduced central and obstructive apneic events. Combining multiple respiratory information from multispectral cameras improved the root mean square error (RMSE) accuracy of the RR estimation from up to 4.64 monospectral data down to 1.60 breaths/min. The median F1 scores for classifying obstructive (0.75 to 0.86) and central apnea (0.75 to 0.93) also improved. Furthermore, the independent consideration of apnea detection led to a more robust system (RMSE of 4.44 vs. 7.96 breaths/min). Our findings may represent a step towards the use of cameras for vital sign monitoring in medical applications.
引用
收藏
页码:350 / 359
页数:10
相关论文
共 50 条
  • [31] Uncertainty Measurements in Non-Contact Neonatal Heart Rate Monitoring
    Dosso, Yasmina Souley
    Greenwood, Kimberley J.
    Harrold, Joann
    Green, James R.
    IEEE ACCESS, 2023, 11 : 144168 - 144179
  • [32] Non-contact thermography-based respiratory rate monitoring in a post-anesthetic care unit
    Kwon, Hye-Mee
    Ikeda, Keita
    Kim, Sung-Hoon
    Thiele, Robert H.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2021, 35 (06) : 1291 - 1297
  • [33] Non-contact thermography-based respiratory rate monitoring in a post-anesthetic care unit
    Hye-Mee Kwon
    Keita Ikeda
    Sung-Hoon Kim
    Robert H. Thiele
    Journal of Clinical Monitoring and Computing, 2021, 35 : 1291 - 1297
  • [34] NON-CONTACT DRIVER CARDIAC PHYSIOLOGICAL MONITORING USING VIDEO DATA
    Qi, Huan
    Wang, Z. Jane
    Miao, Chunyan
    2015 IEEE CHINA SUMMIT & INTERNATIONAL CONFERENCE ON SIGNAL AND INFORMATION PROCESSING, 2015, : 418 - 422
  • [35] Non-Contact Monitoring of Fetal Movement Using Abdominal Video Recording
    Han, Qiao
    Hao, Dongmei
    Yang, Lin
    Yang, Yimin
    Li, Guangfei
    SENSORS, 2023, 23 (10)
  • [36] A Comparative Study of Video Signals for Non-contact Heart Rate Measurement
    Lueangwattana, Chanya
    Kondo, Toshiaki
    Haneishi, Hideaki
    2015 12TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING/ELECTRONICS, COMPUTER, TELECOMMUNICATIONS AND INFORMATION TECHNOLOGY (ECTI-CON), 2015,
  • [37] Non-contact human respiratory rate measurement under dark environments by low-light video enhancement
    Wang, Haipeng
    Zhang, Shuai
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2023, 85
  • [38] The Non-Contact Respiratory Monitoring System Using Thermal Image Processing
    Chiang, Ta-Chi
    Tung, Meng-Hsiung
    Hendrick
    Kurniadi, Dedi
    Wang, Zhi-hao
    Jong, Gwo-Jia
    2016 3RD INTERNATIONAL CONFERENCE ON GREEN TECHNOLOGY AND SUSTAINABLE DEVELOPMENT (GTSD), 2016, : 86 - 92
  • [39] Double-network conductive hydrogel for non-contact respiratory monitoring
    Deng, Shuhang
    Ming, Xiaoran
    Yan, Guilong
    Wang, Li
    Li, Zhenyu
    Chen, Jingyu
    Lai, Jingjuan
    Li, Dong
    Xiang, Dong
    Zhao, Chunxia
    Li, Hui
    Zhang, Xuezhong
    Li, Han
    Wang, Xungai
    Xiao, Yu
    Wu, Yuanpeng
    CHEMICAL ENGINEERING JOURNAL, 2024, 502
  • [40] Monitoring of sleeping animal respiratory pattern using a non-contact bioradar
    Anishchenko, L.
    Gennarelli, G.
    Tataraidze, A.
    Sviryaev, Y.
    Soldovieri, F.
    Ivashov, S.
    SLEEP MEDICINE, 2015, 16 : S92 - S92