Indoor Air Quality in Naturally Ventilated Italian Classrooms

被引:47
|
作者
Fuoco, Fernanda Carmen [1 ]
Stabile, Luca [1 ]
Buonanno, Giorgio [1 ,2 ]
Trassiera, Concepcion Vargas [1 ]
Massimo, Angelamaria [1 ]
Russi, Aldo [1 ]
Mazaheri, Mandana [2 ]
Morawska, Lidia [2 ]
Andrade, Alexandro [3 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, I-03043 Cassino, FR, Italy
[2] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[3] Santa Catarina State Univ, Ctr Hlth Sci & Sport, BR-88080350 Florianopolis, SC, Brazil
关键词
classroom; N-i; N-out ratio; airing by opening windows; particle number concentration; LONG-TERM EXPOSURE; PARTICULATE MATTER; ULTRAFINE PARTICLES; INDOOR/OUTDOOR RELATIONSHIPS; SCHOOL CLASSROOMS; ROADSIDE ENVIRONMENT; AIRBORNE PARTICLES; COARSE PARTICLES; CARBON-DIOXIDE; BLACK CARBON;
D O I
10.3390/atmos6111652
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Characterization of indoor air quality in school classrooms is crucial to children's health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hours during the winter and spring season. The study found the concentrations of indoor particle number were influenced by the concentrations in the outdoors; highest BC values were detected in classrooms during peak traffic time. The effect of different seasons' airing mode on the indoor air quality was also detected. The ratio between indoor and outdoor particles was of 0.85 +/- 0.10 in winter, under airing conditions of short opening window periods, and 1.00 +/- 0.15 in spring when the windows were opened for longer periods. This was associated to a higher degree of penetration of outdoor particles due to longer period of window opening. Lower CO2 levels were found in classrooms in spring (908ppm) than in winter (2206ppm). Additionally, a greater reduction in radon concentrations was found in spring. In addition, high PM10 levels were found in classrooms during break time due to re-suspension of coarse particles.
引用
收藏
页码:1652 / 1675
页数:24
相关论文
共 50 条
  • [41] An analysis of air movement in naturally ventilated classrooms using wind tunnel model studies
    Rahman, SA
    Kannan, KS
    Hasan, RA
    ADVANCES IN MALAYSIAN ENERGY RESEARCH 1998, 1999, : 137 - 150
  • [42] RELATIONSHIPS BETWEEN INDOOR AND OUTDOOR AIR-QUALITY IN 4 NATURALLY VENTILATED OFFICES IN THE UNITED-KINGDOM
    PHILLIPS, JL
    FIELD, R
    GOLDSTONE, M
    REYNOLDS, GL
    LESTER, JN
    PERRY, R
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1993, 27 (11): : 1743 - 1753
  • [43] A seasonal assessment of indoor air quality and thermal performance in naturally ventilated airtight energy-efficient dwellings
    Alhindawi, Ibrahim
    Mcgrath, James A.
    Sood, Divyanshu
    O'Donnell, James
    Byrne, Miriam A.
    BUILDING AND ENVIRONMENT, 2025, 276
  • [44] Indoor air quality investigations in a naturally ventilated school building located close to an urban roadway in Chennai, India
    Chithra, V. S.
    Nagendra, S. M. Shiva
    BUILDING AND ENVIRONMENT, 2012, 54 : 159 - 167
  • [45] Indoor air quality (IAQ) in naturally-ventilated primary schools in the UK: Occupant-related factors
    Korsavi, Sepideh Sadat
    Montazami, Azadeh
    Mumovic, Dejan
    BUILDING AND ENVIRONMENT, 2020, 180
  • [46] Perceived indoor air quality in naturally ventilated primary schools in the UK: Impact of environmental variables and thermal sensation
    Korsavi, Sepideh Sadat
    Montazami, Azadeh
    Mumovic, Dejan
    INDOOR AIR, 2021, 31 (02) : 480 - 501
  • [47] Solar-assisted naturally ventilated double skin facade for buildings: Room impacts and indoor air quality
    Tao, Yao
    Yan, Yihuan
    Fang, Xiang
    Zhang, Haihua
    Tu, Jiyuan
    Shi, Long
    BUILDING AND ENVIRONMENT, 2022, 216
  • [48] Relationship of indoor and outdoor air pollutants in a naturally ventilated historical building envelope
    Lopez-Aparicio, S.
    Smolik, J.
    Maskova, L.
    Souckova, M.
    Grontoft, T.
    Ondrackova, L.
    Stankiewicz, J.
    BUILDING AND ENVIRONMENT, 2011, 46 (07) : 1460 - 1468
  • [49] Assessing the Fluctuation of Indoor Thermal Conditions in Naturally Ventilated Classrooms Through K-Means Clustering
    Miao, Sen
    Gangolells, Marta
    Tejedor, Blanca
    INDOOR AIR, 2025, 2025 (01)
  • [50] Ability to Determine the Quality of Indoor Air in Classrooms without Sensors
    Pietrucha, Tomasz
    9TH CONFERENCE ON INTERDISCIPLINARY PROBLEMS IN ENVIRONMENTAL PROTECTION AND ENGINEERING (EKO-DOK 2017), 2017, 17