Indoor Air Quality in Naturally Ventilated Italian Classrooms

被引:47
|
作者
Fuoco, Fernanda Carmen [1 ]
Stabile, Luca [1 ]
Buonanno, Giorgio [1 ,2 ]
Trassiera, Concepcion Vargas [1 ]
Massimo, Angelamaria [1 ]
Russi, Aldo [1 ]
Mazaheri, Mandana [2 ]
Morawska, Lidia [2 ]
Andrade, Alexandro [3 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, I-03043 Cassino, FR, Italy
[2] Queensland Univ Technol, Int Lab Air Qual & Hlth, Brisbane, Qld 4001, Australia
[3] Santa Catarina State Univ, Ctr Hlth Sci & Sport, BR-88080350 Florianopolis, SC, Brazil
关键词
classroom; N-i; N-out ratio; airing by opening windows; particle number concentration; LONG-TERM EXPOSURE; PARTICULATE MATTER; ULTRAFINE PARTICLES; INDOOR/OUTDOOR RELATIONSHIPS; SCHOOL CLASSROOMS; ROADSIDE ENVIRONMENT; AIRBORNE PARTICLES; COARSE PARTICLES; CARBON-DIOXIDE; BLACK CARBON;
D O I
10.3390/atmos6111652
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Characterization of indoor air quality in school classrooms is crucial to children's health and performance. The present study was undertaken to characterize the indoor air quality in six naturally ventilated classrooms of three schools in Cassino (Italy). Indoor particle number, mass, black carbon, CO2 and radon concentrations, as well as outdoor particle number were measured within school hours during the winter and spring season. The study found the concentrations of indoor particle number were influenced by the concentrations in the outdoors; highest BC values were detected in classrooms during peak traffic time. The effect of different seasons' airing mode on the indoor air quality was also detected. The ratio between indoor and outdoor particles was of 0.85 +/- 0.10 in winter, under airing conditions of short opening window periods, and 1.00 +/- 0.15 in spring when the windows were opened for longer periods. This was associated to a higher degree of penetration of outdoor particles due to longer period of window opening. Lower CO2 levels were found in classrooms in spring (908ppm) than in winter (2206ppm). Additionally, a greater reduction in radon concentrations was found in spring. In addition, high PM10 levels were found in classrooms during break time due to re-suspension of coarse particles.
引用
收藏
页码:1652 / 1675
页数:24
相关论文
共 50 条
  • [31] Coupled heat and mass transfer analysis for indoor air quality and thermal comfort in naturally ventilated offices
    Huang, Zhaopeng
    Li, Qiong
    He, Yiyuan
    Ding, Xiang
    Dong, Yunli
    Gao, Wenfeng
    APPLIED THERMAL ENGINEERING, 2025, 269
  • [32] Effects of covid-induced lockdown on inhabitants' perception of indoor air quality in naturally ventilated homes
    Fernandez-Aguera, Jesica
    Dominguez-Amarillo, Samuel
    Angel Campano, Miguel
    Al-Khatri, Hanan
    AIR QUALITY ATMOSPHERE AND HEALTH, 2023, 16 (02): : 193 - 212
  • [33] Improving the indoor air quality (IAQ) in naturally ventilated lecture hall with a single facade by solar chimneys
    Fikry A.
    Elsayed A.
    Elsayed, Asmaa (asmaa.elshoura83@gmail.com), 1600, Springer Science and Business Media B.V. (68):
  • [34] Developing an algorithm to illustrate the likelihood of the dissatisfaction rate with relation to the indoor temperature in naturally ventilated classrooms
    Montazami, Azadeh
    Gaterell, Mark
    Nicol, Fergus
    Lumley, Mark
    Thoua, Chryssa
    BUILDING AND ENVIRONMENT, 2017, 111 : 61 - 71
  • [35] How teacher behaviors and perceptions, air change rates, and portable air purifiers affect indoor air quality in naturally ventilated schools
    Xia, Tian
    Raneses, Julia
    Schmiesing, Brixon
    Garcia, Raquel
    Walding, Alison
    Demajo, Richardo
    Schulz, Amy
    Batterman, Stuart A.
    FRONTIERS IN PUBLIC HEALTH, 2024, 12
  • [36] Indoor Air Quality and Bioaerosols in Spanish University Classrooms
    Fuentes-Ferragud, Esther
    Lopez, Antonio
    Piera, Juan Miguel
    Yusa, Vicent
    Garrigues, Salvador
    de la Guardia, Miguel
    Labrador, F. Xavier Lopez
    Camaro, Marisa
    Ibanez, Maria
    Coscolla, Clara
    TOXICS, 2024, 12 (03)
  • [37] Investigation of Indoor Air Quality in Primary School Classrooms
    Hou, Yuefei
    Liu, Junjie
    Li, Jiayu
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 830 - 837
  • [38] Indoor Air Quality Performance of Ventilation Systems in Classrooms
    Moon, Hyeun Jun
    Sohn, Jong-Ryeul
    Hwang, Taeyon
    JOURNAL OF ASIAN ARCHITECTURE AND BUILDING ENGINEERING, 2016, 15 (02) : 343 - 348
  • [39] WSN Based Indoor Air Quality Monitoring In Classrooms
    Wang, S. K.
    Chew, S. P.
    Jusoh, M. T.
    Khairunissa, A.
    Leong, K. Y.
    Azid, A. A.
    11TH ASIAN CONFERENCE ON CHEMICAL SENSORS (ACCS2015), 2017, 1808
  • [40] Field study on thermal comfort in naturally ventilated and air-conditioned university classrooms
    Fabozzi, Michael
    Dama, Alessandro
    INDOOR AND BUILT ENVIRONMENT, 2020, 29 (06) : 851 - 859