BRACHYTHERAPY DOSIMETRY SPECIAL FEATURE: REVIEW ARTICLE In vivo dosimetry: trends and prospects for brachytherapy

被引:57
|
作者
Kertzscher, G. [1 ]
Rosenfeld, A. [2 ]
Beddar, S. [3 ]
Tanderup, K. [4 ]
Cygler, J. E. [5 ]
机构
[1] Tech Univ Denmark, Ctr Nucl Technol, Roskilde, Denmark
[2] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[4] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
[5] Ottawa Hosp, Ctr Canc, Dept Med Phys, Ottawa, ON, Canada
来源
BRITISH JOURNAL OF RADIOLOGY | 2014年 / 87卷 / 1041期
关键词
HIGH-DOSE-RATE; CERVIX CANCER BRACHYTHERAPY; PLASTIC SCINTILLATION DETECTORS; RATE INTRACAVITARY BRACHYTHERAPY; REAL-TIME VERIFICATION; RECTAL WALL DOSIMETRY; HDR BRACHYTHERAPY; GEC-ESTRO; APPLICATOR RECONSTRUCTION; TEMPERATURE-DEPENDENCE;
D O I
10.1259/bjr.20140206
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The error types during brachytherapy (BT) treatments and their occurrence rates are not well known. The limited knowledge is partly attributed to the lack of independent verification systems of the treatment progression in the clinical workflow routine. Within the field of in vivo dosimetry (IVD), it is established that real-time IVD can provide efficient error detection and treatment verification. However, it is also recognized that widespread implementations are hampered by the lack of available high-accuracy IVD systems that are straightforward for the clinical staff to use. This article highlights the capabilities of the state-of-the-art IVD technology in the context of error detection and quality assurance (QA) and discusses related prospects of the latest developments within the field. The article emphasizes the main challenges responsible for the limited practice of IVD and provides descriptions on how they can be overcome. Finally, the article suggests a framework for collaborations between BT clinics that implemented IVD on a routine basis and postulates that such collaborations could improve BT QA measures and the knowledge about BT error types and their occurrence rates.
引用
收藏
页数:16
相关论文
共 50 条
  • [31] In vivo dosimetry and seed localization in prostate brachytherapy with permanent implants
    Rosenfeld, AB
    Cutajar, DL
    Lerch, MLF
    Takacs, GJ
    Brady, J
    Braddock, T
    Perevertaylo, VL
    Bucci, J
    Kearsley, J
    Zaider, M
    Zelefsky, M
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 3013 - 3018
  • [32] In Vivo Dosimetry for HDR Brachytherapy Using a Scintillating Fiber Dosimeter
    Therriault-Proulx, F.
    Villeneuve, M.
    Martin, A.
    Gingras, L.
    Beddar, S.
    Beaulieu, L.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [33] Reconstruction of delivered dose based on in vivo dosimetry in prostate brachytherapy
    Jorgensen, E.
    Rylander, S.
    Buus, S.
    Bentzen, L.
    Hokland, S. B.
    With, A. K. M.
    Kertzscher, G.
    Tanderup, K.
    Johansen, J. G.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S36 - S37
  • [34] Development of an inorganic scintillation detector system for in vivo dosimetry for brachytherapy
    Kertzscher, G.
    Beddar, S.
    RADIOTHERAPY AND ONCOLOGY, 2018, 127 : S89 - S90
  • [35] Future directions of in vivo dosimetry for external beam radiotherapy and brachytherapy
    Verhaegen, Frank
    Fonseca, Gabriel P.
    Johansen, Jacob G.
    Beaulieu, Luc
    Beddar, Sam
    Greer, Peter
    Jornet, Nuria
    Kertzscher, Gustavo
    McCurdy, Boyd
    Smith, Ryan L.
    Mijnheer, Ben
    Olaciregui-Ruiz, Igor
    Tanderup, Kari
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2020, 16 : 18 - 19
  • [36] Time-resolved in vivo dosimetry for source tracking in brachytherapy
    Johansen, Jacob Graversen
    Rylander, Susanne
    Buus, Simon
    Bentzen, Lise
    Hokland, Steffen Bjerre
    Sondergaard, Christian Skou
    With, Anders Karl Mikael
    Kertzscher, Gustavo
    Tanderup, Kari
    BRACHYTHERAPY, 2018, 17 (01) : 122 - 132
  • [37] In-vivo dosimetry for gynaecological brachytherapy:: Physical and clinical considerations
    Waldhäusl, C
    Wambersie, A
    Pötter, R
    Georg, D
    RADIOTHERAPY AND ONCOLOGY, 2005, 77 (03) : 310 - 317
  • [38] Plastic Scintillation Detector Calibration Procedure for Brachytherapy in Vivo Dosimetry
    Herreros, A.
    Perez-Calatayud, J.
    Ballester, F.
    MEDICAL PHYSICS, 2020, 47 (06) : E473 - E473
  • [39] Beta dosimetry with microMOSFETs for endovascular brachytherapy
    Drud, Eva
    Todorovic, Manuel
    Schoenborn, Thies
    Schmidt, Rainer
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (23): : 5977 - 5986
  • [40] CT-Based dosimetry in brachytherapy
    Modolell, I
    Picón, C
    Muñoz, C
    Gracia, A
    Lizuain, MC
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 : S57 - S57