In-vivo dosimetry for gynaecological brachytherapy:: Physical and clinical considerations

被引:58
|
作者
Waldhäusl, C
Wambersie, A
Pötter, R
Georg, D
机构
[1] Univ Vienna, Dept Radiotherapy & Radiobiol, Vienna, Austria
[2] Univ Catholique Louvain, B-1200 Brussels, Belgium
关键词
in-vivo dosimetry; semiconductor diodes; brachytherapy; ICRU reference points; gynaecology;
D O I
10.1016/j.radonc.2005.09.004
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: The study aimed to estimate the dosimetric uncertainty using diodes (PTW/Germany) for a high-dose rate Iridum-192 source under clinical conditions. Finally, the role of in-vivo dosimetry for cervix cancer patients was evaluated. Material and methods: First, diode calibration and factors influencing diode response were investigated and phantom studies compared doses measured and computed by the treatment planning system. Based on that, the uncertainty for diode measurements was estimated to be 7% (1 sigma). Secondly, 55 applications of patients with cervix carcinoma were evaluated. Doses in rectum and bladder were measured and compared to the computed doses and differences were calculated. If the differences exceeded 10% the corresponding shift in probe position was evaluated. Additionally, the in-vivo dosimetry data were compared to doses at the ICRU 38 [ICRU Report No. 38, dose and volume specification for reporting intracavitary therapy in gynaecology. In: Chassagne D, Dutreix A, Almond P, Burgers J, Busch M, Joslin C editors. International commissioning on radiation units and measurements. Bethesda: 1985.] reference points for rectum and bladder. Results: In patients, in-vivo dosimetry resulted in differences between calculated and measured doses ranging from -31 to +90% (mean 11%) for the rectum and from -27 to +26% (mean 4%) for the bladder. Shifts in probe position of 2.5 mm for the rectal probe and 3.5 mm for the bladder probe caused dose differences exceeding 10%. The dose at the ICRU rectum reference point was underestimated by the calculated doses at probe position ranging from -61 to 156% (mean 29%). The dose to the ICRU bladder reference point was underestimated by the calculated dose ranging from 12 to 162% (mean 58%). Conclusion: The study shows that diode accuracy and reproducibility is sufficient for clinical applications. For accurate in-vivo dosimetry geometric conditions are of outmost importance. It is recommended that in-vivo dosimetry should be performed in addition to computation. (c) 2005 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 77 (2005) 310-317.
引用
收藏
页码:310 / 317
页数:8
相关论文
共 50 条
  • [1] IN-VIVO DOSIMETRY FOR GYNAECOLOGICAL BRACHYTHERAPY USING A NOVEL DETECTOR SYSTEM.
    Reniers, B.
    Landry, G.
    Eichner, R.
    Abdelbasset, H.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 : S53 - S54
  • [2] The clinical application of in vivo dosimetry for gynaecological brachytherapy: A scoping review
    Chowdhury, Amani A.
    Bolton, Steve
    Lowe, Gerry
    Osorio, Eliana Vasquez
    Hamblyn, William
    Hoskin, Peter J.
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2025, 33
  • [3] In-vivo dosimetry in brachytherapy
    Cygler, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S55 - S55
  • [4] Applicability of Glass Dosimeters for In-vivo Dosimetry in Brachytherapy
    Moon, Sun Young
    Son, Jaeman
    Yoon, Myonggeun
    Jeang, EunHee
    Lim, Young Kyung
    Chung, Weon Kyu
    Kim, Dong Wook
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2018, 72 (11) : 1320 - 1325
  • [5] Applicability of Glass Dosimeters for In-vivo Dosimetry in Brachytherapy
    Sun Young Moon
    Jaeman Son
    Myonggeun Yoon
    EunHee Jeang
    Young Kyung Lim
    Weon Kyu Chung
    Dong Wook Kim
    Journal of the Korean Physical Society, 2018, 72 : 1320 - 1325
  • [6] IN VIVO DOSIMETRY FOR GYNAECOLOGICAL BRACHYTHERAPY BASED ON A NOVEL RADPOS SYSTEM.
    Reniers, B.
    Landry, G.
    Eichner, R.
    Bloemen-van Gurp, E.
    Murrer, L.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S118 - S119
  • [7] Brachytherapy - Clinical dosimetry and the integration of therapies of gynaecological cancer - Commentary
    Joslin, CA
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (824): : 689 - 692
  • [8] Real-time in-vivo dosimetry in HDR prostate brachytherapy
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S27 - S28
  • [9] Studies on optical fiber dosimeters for in-vivo dosimetry in HDR brachytherapy
    Moutinho, L.
    Freitas, H.
    Melo, J.
    Veloso, J. F. C. A.
    Rachinhas, P. J.
    Simoes, P. C. P. S.
    Santos, J. A. M.
    Pereira, A.
    Silva, J.
    Pinto, S.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S424 - S425
  • [10] Real-time in-vivo dosimetry for HDR prostate brachytherapy
    Mamo, A.
    Mason, J.
    Al-Qaisieh, B.
    Henry, A.
    Okkalides, D.
    Bownes, P.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S85 - S86