An amperometric enzyme electrode for glucose using immobilized glucose oxidase in a ferrocene attached poly(4-vinylpyridine) multilayer film

被引:0
|
作者
Hou, SF
Fang, HQ
Chen, HY
机构
[1] NANJING UNIV,DEPT CHEM,NANJING 210093,PEOPLES R CHINA
[2] NANJING UNIV,STATE KEY LAB COORDINAT CHEM,NANJING 210093,PEOPLES R CHINA
关键词
multilayer film; glucose oxidase; self-assembled monolayer; ferrocene-attached poly(4-vinylpyridine);
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode for glucose has been prepared by immobilized glucose oxidase (GOD) in a multilayer film based on a thiol self-assembled monolayer at a gold electrode. The multilayer film of GOD and ferrocene attached poly(4-vinylpyridine) (Fc-PVP) complex is formed by electrostatic force. Fc-PVP as a polyelectrolyte in which ferrocene is as a mediator, acts with GOD to form a complex. The linear range of the enzyme electrode is extended up to 10mmol/L of glucose due to the addition of 5 GOD layers. The enzyme electrode is sensitive to glucose, 0.10 mmol/L glucose leads to a response current of 22nA and the detection limit is down to 0.01 mmol/L. Ascorbic acid and uric acid have no interference for the determination of glucose. The enzyme electrode is stable over 3 weeks.
引用
收藏
页码:1631 / 1641
页数:11
相关论文
共 50 条
  • [31] Amperometric Glucose Biosensor Based on Titanium Electrode Modified with Prussian Blue Layer and Immobilized Glucose Oxidase
    Valiuniene, A.
    Virbickas, P.
    Rekertaite, A.
    Ramanavicius, A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : B781 - B784
  • [32] AN ENZYME ELECTRODE FOR GLUCOSE CONSISTING OF GLUCOSE-OXIDASE IMMOBILIZED AT A BENZOQUINONE-MODIFIED CARBON ELECTRODE
    HU, J
    TURNER, APF
    ANALYTICAL LETTERS, 1991, 24 (01) : 15 - 24
  • [33] MODEL FOR AMPEROMETRIC ENZYME ELECTRODE OBTAINED THROUGH DIGITAL-SIMULATION AND APPLIED TO IMMOBILIZED GLUCOSE OXIDASE SYSTEM
    MELL, LD
    MALOY, JT
    ANALYTICAL CHEMISTRY, 1975, 47 (02) : 299 - 307
  • [34] An amperometric biosensor for glucose based on electrodeposited redox polymer/glucose oxidase film on a gold electrode
    Fei, JJ
    Wu, YH
    Ji, XB
    Wang, J
    Hu, SS
    Gao, ZQ
    ANALYTICAL SCIENCES, 2003, 19 (09) : 1259 - 1263
  • [35] An Amperometric Biosensor for Glucose Based on Electrodeposited Redox Polymer/Glucose Oxidase Film on a Gold Electrode
    Junjie Fei
    Yunhua Wu
    Xiaobo Ji
    Jing Wang
    Shengshui Hu
    Zhiqiang Gao
    Analytical Sciences, 2003, 19 : 1259 - 1263
  • [36] GLUCOSE FAST-RESPONSE AMPEROMETRIC SENSOR BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN AN ELECTROPOLYMERIZED POLY(ORTHO-PHENYLENEDIAMINE) FILM
    MALITESTA, C
    PALMISANO, F
    TORSI, L
    ZAMBONIN, PG
    ANALYTICAL CHEMISTRY, 1990, 62 (24) : 2735 - 2740
  • [37] Amperometric glucose determination by means of glucose oxidase immobilized on a cellulose acetate film: Dependence on the immobilization procedures
    Portaccio, Marianna
    Durante, Daniela
    Viggiano, Andrea
    Di Martino, Silvana
    De Luca, Paola
    Di Tuoro, Daniela
    Bencivenga, Umberto
    Rossi, Sergio
    Canciglia, Paolo
    De Luca, Bruno
    Mita, Datniano Gustavo
    ELECTROANALYSIS, 2007, 19 (17) : 1787 - 1793
  • [38] An Amperometric Biosensor for Glucose Determination Prepared from Glucose Oxidase Immobilized in Polyaniline-Polyvinylsulfonate Film
    Arslan, Fatma
    Ustabas, Selvin
    Arslan, Halit
    SENSORS, 2011, 11 (08) : 8152 - 8163
  • [39] Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer
    Zhu, JH
    Zhu, ZQ
    Lai, ZS
    Wang, R
    Guo, XM
    Wu, XQ
    Zhang, GX
    Zhang, ZR
    Zhang, ZR
    Wang, YT
    Chen, ZY
    SENSORS, 2002, 2 (04): : 127 - 136
  • [40] Disposable amperometric glucose sensor electrode with enzyme-immobilized nitrocellulose strip
    Cui, G
    Yoo, JH
    Woo, BW
    Kim, SS
    Cha, GS
    Nam, H
    TALANTA, 2001, 54 (06) : 1105 - 1111