An amperometric enzyme electrode for glucose using immobilized glucose oxidase in a ferrocene attached poly(4-vinylpyridine) multilayer film

被引:0
|
作者
Hou, SF
Fang, HQ
Chen, HY
机构
[1] NANJING UNIV,DEPT CHEM,NANJING 210093,PEOPLES R CHINA
[2] NANJING UNIV,STATE KEY LAB COORDINAT CHEM,NANJING 210093,PEOPLES R CHINA
关键词
multilayer film; glucose oxidase; self-assembled monolayer; ferrocene-attached poly(4-vinylpyridine);
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode for glucose has been prepared by immobilized glucose oxidase (GOD) in a multilayer film based on a thiol self-assembled monolayer at a gold electrode. The multilayer film of GOD and ferrocene attached poly(4-vinylpyridine) (Fc-PVP) complex is formed by electrostatic force. Fc-PVP as a polyelectrolyte in which ferrocene is as a mediator, acts with GOD to form a complex. The linear range of the enzyme electrode is extended up to 10mmol/L of glucose due to the addition of 5 GOD layers. The enzyme electrode is sensitive to glucose, 0.10 mmol/L glucose leads to a response current of 22nA and the detection limit is down to 0.01 mmol/L. Ascorbic acid and uric acid have no interference for the determination of glucose. The enzyme electrode is stable over 3 weeks.
引用
收藏
页码:1631 / 1641
页数:11
相关论文
共 50 条
  • [21] AMPEROMETRIC DETERMINATION OF GLUCOSE WITH A FERROCENE-MEDIATED GLUCOSE-OXIDASE POLYACRYLAMIDE-GEL ELECTRODE
    LANGE, MA
    CHAMBERS, JQ
    ANALYTICA CHIMICA ACTA, 1985, 175 (SEP) : 89 - 97
  • [22] Amperometric enzyme electrode for free cholesterol determination prepared with cholesterol oxidase immobilized in poly(vinylferrocenium) film
    Ozer, B. Cem
    Ozyoruk, Haluk
    Celebi, Serdar S.
    Yildiz, Atilla
    ENZYME AND MICROBIAL TECHNOLOGY, 2007, 40 (02) : 262 - 265
  • [23] Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer
    Garjonyte, R.
    Malinauskas, A.
    Sensors and Actuators, B: Chemical, 1999, 56 (01): : 85 - 92
  • [24] Amperometric glucose biosensor based on glucose oxidase immobilized in poly(o-phenylenediamine) layer
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 1999, 56 (1-2) : 85 - 92
  • [25] AMPEROMETRIC GLUCOSE SENSORS BASED ON FERROCENE-MODIFIED POLY(ETHYLENE OXIDE) AND GLUCOSE-OXIDASE
    HALE, PD
    LAN, HL
    BOGUSLAVSKY, LI
    KARAN, HI
    OKAMOTO, Y
    SKOTHEIM, TA
    ANALYTICA CHIMICA ACTA, 1991, 251 (1-2) : 121 - 128
  • [26] Amperometric enzyme electrode for urea determination using immobilized urease in poly (vinylferrocenium) film
    Kuralay, F
    Özyörük, H
    Yildiz, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 114 (01): : 500 - 506
  • [27] Polypyrrole-based Enzyme Electrode with Immobilized Glucose Oxidase for Electrochemical Determination of Glucose
    Jugovic, Branimir
    Grgur, Branimir
    Antov, Mirjana
    Knezevic-Jugovic, Zorica
    Stevanovic, Jasmina
    Gvozdenovic, Milica
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (02): : 1152 - 1161
  • [28] ENZYME THERMISTOR DETERMINATION OF GLUCOSE IN SERUM USING IMMOBILIZED GLUCOSE OXIDASE
    DANIELSSON, B
    GADD, K
    MATTIASSON, B
    MOSBACH, K
    CLINICA CHIMICA ACTA, 1977, 81 (02) : 163 - 175
  • [29] An enzyme-chemically modified carbon paste electrode as a glucose sensor based on glucose oxidase immobilized in a polyaniline film
    Hu, SS
    Luo, J
    Cui, D
    ANALYTICAL SCIENCES, 1999, 15 (06) : 585 - 588
  • [30] An Enzyme-Chemically Modified Carbon Paste Electrode as a Glucose Sensor Based on Glucose Oxidase Immobilized in a Polyaniline Film
    Shengshui Hu
    Jun Luo
    Dafu Cui
    Analytical Sciences, 1999, 15 : 585 - 588