Setup error and motion during deep inspiration breath-hold breast radiotherapy measured with continuous portal imaging

被引:42
|
作者
Lutz, Christina Maria [1 ]
Poulsen, Per Rugaard [2 ,3 ]
Fledelius, Walther [3 ]
Offersen, Birgitte Vrou [2 ,3 ]
Thomsen, Mette Skovhus [1 ]
机构
[1] Aarhus Univ Hosp, Dept Med Phys, DK-8000 Aarhus, Denmark
[2] Aarhus Univ, Inst Clin Med, Aarhus, Denmark
[3] Aarhus Univ Hosp, Dept Oncol, DK-8000 Aarhus, Denmark
关键词
CANCER PATIENTS; RANDOMIZED-TRIALS; RADIATION-THERAPY; HEART-DISEASE; WOMEN; RISK; REPRODUCIBILITY; IRRADIATION; SURVIVORS; GUIDANCE;
D O I
10.3109/0284186X.2015.1045625
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. The position and residual motion of the chest wall of breast cancer patients during treatment in deep inspiration breath-hold (DIBH) were investigated. Material and methods. The study included 58 left-sided breast cancer patients treated with DIBH three-dimensional (3D) conformal radiotherapy in 15 or 25 fractions. The DIBH levels were monitored using an external marker block placed on the chest, either shifted 5 cm to the right at the level of the xiphoid process (Group 1, 27 consecutive patients) or placed medially on the inferior part of the sternum (Group 2, 31 consecutive patients). At every third treatment fraction, continuous portal images were acquired. The time-resolved chest wall position during treatment was compared with the planned position to determine the inter-fraction setup errors and the intra-fraction motion of the chest wall. Results. The DIBH compliance was 95% during both recruitment periods. A tendency of smaller inter-fraction setup errors and intra-fraction motion was observed for group 2 (medial marker block position). However, apart from a significantly reduced inter-field random shift (sigma = 1.7 mm vs. sigma = 0.9 mm, p = 0.005), no statistically significant differences between the groups were found. In a combined analysis, the group mean inter-fraction setup error was M = - 0.1 mm, with random and systematic errors of sigma = 1.7 mm and sigma = 1.4 mm. The group mean inter-field shift was M = 0.0 (sigma = 1.3 mm and sigma = 1.1 mm) and the group mean standard deviation of the intra-field motion was 0.5 mm. The absolute setup error had a maximum of 16.3 mm, exceeding 5 mm in 2.2% of the imaged fields. Conclusion. Compared to free breathing treatments, the primary benefit of the DIBH technique was the separation of the heart from the target rather than more accurate targeting. Despite a small gating window, occasional large errors in the chest wall position were observed for some patients, illustrating limitations of the external marker block as surrogate in a broad patient population.
引用
收藏
页码:193 / 200
页数:8
相关论文
共 50 条
  • [11] Evaluation of target and cardiac position during visually monitored deep inspiration breath-hold for breast radiotherapy
    Conroy, Leigh
    Yeung, Rosanna
    Watt, Elizabeth
    Quirk, Sarah
    Long, Karen
    Hudson, Alana
    Tien Phan
    Smith, Wendy L.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (04): : 25 - 36
  • [12] Cardiac Movement in Deep Inspiration Breath-Hold for Left-Breast Cancer Radiotherapy
    Kim, M.
    Lee, S.
    Suh, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 162 - 162
  • [13] Gated Radiotherapy with deep inspiration breath-hold in left-sided breast cancer
    Micke, O.
    Kisters, K.
    Schaefer, U.
    Muecke, R.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S910 - S910
  • [14] Deep inspiration breath-hold (DIBH) radiotherapy in left-sided breast cancer
    Hepp, Rodrigo
    Ammerpohl, Mark
    Morgenstern, Christina
    Nielinger, Lisa
    Erichsen, Patricia
    Abdallah, Abdallah
    Galalae, Razvan
    STRAHLENTHERAPIE UND ONKOLOGIE, 2015, 191 (09) : 710 - 716
  • [15] Interfraction heart motion during Deep Inspiration Breath Hold (DIBH) radiotherapy measured by CBCT.
    Benkhaled, S.
    Van Gestel, D.
    Desmet, A.
    Rodriguez, D.
    Jourani, Y.
    De Caluwe, A.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S86 - S87
  • [16] ASSESSMENT OF SETUP VARIABILITY FOR BREATH-HOLD RADIOTHERAPY FOR BREAST CANCER PATIENTS BY SURFACE IMAGING
    Alderliesten, T.
    Sonke, J. J.
    Heddes, R.
    Betgen, A.
    Remeijer, P.
    van Vliet-Vroegindewij, C.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S65 - S65
  • [17] Setup Variation in Deep Inspiration Breath-Hold for Radiotherapy of Breast Cancer Tumor Bed Assessed with RPM-Guided CBCT
    Shen, S.
    Duan, J.
    Keene, K.
    Yuan, Y.
    Klepczyk, L.
    Meredith, R.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [18] Evaluation of daily residual pancreatic tumor motion for deep-inspiration breath-hold radiotherapy
    Mao, Weihua
    Wu, Binbin
    Ding, Kai
    Han-Oh, Sarah
    Narang, Amol
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2025,
  • [19] Evaluation of the voluntary deep inspiration breath-hold reproducibility in left-sided breast radiotherapy
    Ertan, Ferihan
    Sahin, Serdar
    Azak, Can
    Karakaya, Ebru
    Altundag, Muzaffer Bedri
    Goksel, Fatih
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2022, 30 (06) : 1057 - 1066
  • [20] Radiotherapy in breast cancer with voluntary deep-inspiration breath-hold using BrainLab Exactrac
    Ippolito, E.
    D'Angelillo, R.
    Sicilia, A.
    Silipigni, S.
    Floreno, B.
    Molfese, E.
    Di Donato, A.
    Trecca, P.
    Gaudino, D.
    Stimato, G.
    Ramella, S.
    Trodella, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S817 - S817