Motion correction for routine X-ray lung CT imaging

被引:2
|
作者
Kim, Doil [1 ]
Choi, Jiyoung [1 ]
Lee, Duhgoon [1 ]
Kim, Hyesun [1 ]
Jung, Jiyoung [1 ]
Cho, Minkook [1 ]
Lee, Kyoung-Yong [1 ]
机构
[1] Samsung Elect Co Ltd, CT R&D Grp, Hlth & Med Equipment Business, Suwon, South Korea
关键词
D O I
10.1038/s41598-021-83403-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A novel motion correction algorithm for X-ray lung CT imaging has been developed recently. It was designed to perform for routine chest or thorax CT scans without gating, namely axial or helical scans with pitch around 1.0. The algorithm makes use of two conjugate partial angle reconstruction images for motion estimation via non-rigid registration which is followed by a motion compensated reconstruction. Differently from other conventional approaches, no segmentation is adopted in motion estimation. This makes motion estimation of various fine lung structures possible. The aim of this study is to explore the performance of the proposed method in correcting the lung motion artifacts which arise even under routine CT scans with breath-hold. The artifacts are known to mimic various lung diseases, so it is of great interest to address the problem. For that purpose, a moving phantom experiment and clinical study (seven cases) were conducted. We selected the entropy and positivity as figure of merits to compare the reconstructed images before and after the motion correction. Results of both phantom and clinical studies showed a statistically significant improvement by the proposed method, namely up to 53.6% (p < 0.05) and up to 35.5% (p < 0.05) improvement by means of the positivity measure, respectively. Images of the proposed method show significantly reduced motion artifacts of various lung structures such as lung parenchyma, pulmonary vessels, and airways which are prominent in FBP images. Results of two exemplary cases also showed great potential of the proposed method in correcting motion artifacts of the aorta which is known to mimic aortic dissection. Compared to other approaches, the proposed method provides an excellent performance and a fully automatic workflow. In addition, it has a great potential to handle motions in wide range of organs such as lung structures and the aorta. We expect that this would pave a way toward innovations in chest and thorax CT imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] ROUTINE X-RAY PELVIMETRY
    THOMS, H
    OBSTETRICS AND GYNECOLOGY, 1956, 8 (06): : 745 - 747
  • [32] Attenuation correction of myocardial SPECT images with X-ray CT: Effects of registration errors between X-ray CT and SPECT
    Takahashi, Y
    Murase, K
    Higashino, H
    Mochizuki, T
    Motomura, N
    ANNALS OF NUCLEAR MEDICINE, 2002, 16 (06) : 431 - 435
  • [33] Attenuation correction of myocardial SPECT images with X-ray CT: Effects of registration errors between X-ray CT and SPECT
    Yasuyuki Takahashi
    Kenya Murase
    Hiroshi Higashino
    Teruhito Mochizuki
    Nobutoku Motomura
    Annals of Nuclear Medicine, 2002, 16 : 431 - 435
  • [34] Local Motion Detection, Characterization, and Quantification for X-ray CT
    Hsieh, Jiang
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925
  • [35] TOWARDS BEAM HARDENING CORRECTION FOR POLYCHROMATIC X-RAY CT
    Park, Hyoung Suk
    Gao, Hao
    Lee, Sung Min
    Seo, Jin Keun
    JOURNAL OF COMPUTATIONAL MATHEMATICS, 2016, 34 (06) : 671 - 682
  • [36] An analysis of scatter characteristics in x-ray CT spectral correction
    Zhang, Tao
    Chen, Zhiqiang
    Zhou, Hao
    Bennett, N. Robert
    Wang, Adam S.
    Gao, Hewei
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (07):
  • [37] Optimization of x-ray dark-field CT for human-scale lung imaging
    Guo, Peiyuan
    Spindler, Simon
    Rawlik, Michal
    Lu, Jincheng
    Men, Longchao
    Hong, Mingzhi
    Stampanoni, Marco
    Yin, Hongxia
    Xu, Yan
    Wang, Zhenchang
    Zhang, Li
    Wang, Zhentian
    MEDICAL PHYSICS, 2025,
  • [38] In vivo tomographic imaging of lung colonization of tumour in mouse with simultaneous fluorescence and X-ray CT
    Zhang, Bin
    Gao, Fuping
    Wang, Mengjiao
    Cao, Xu
    Liu, Fei
    Wang, Xin
    Luo, Jianwen
    Wang, Guangzhi
    Bai, Jing
    JOURNAL OF BIOPHOTONICS, 2014, 7 (1-2) : 110 - 116
  • [39] The principles and effectiveness of X-ray scatter correction software for diagnostic X-ray imaging: A scoping review
    Sayed, Mohammad
    Knapp, Karen M.
    Fulford, Jon
    Heales, Christine
    Alqahtani, Saeed J.
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 158
  • [40] Lung Resection: How useful are routine postoperative X-ray Examinations?
    Lorenz, Judith
    ZENTRALBLATT FUR CHIRURGIE, 2024, 149 : S5 - S5