Motion correction for routine X-ray lung CT imaging

被引:2
|
作者
Kim, Doil [1 ]
Choi, Jiyoung [1 ]
Lee, Duhgoon [1 ]
Kim, Hyesun [1 ]
Jung, Jiyoung [1 ]
Cho, Minkook [1 ]
Lee, Kyoung-Yong [1 ]
机构
[1] Samsung Elect Co Ltd, CT R&D Grp, Hlth & Med Equipment Business, Suwon, South Korea
关键词
D O I
10.1038/s41598-021-83403-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A novel motion correction algorithm for X-ray lung CT imaging has been developed recently. It was designed to perform for routine chest or thorax CT scans without gating, namely axial or helical scans with pitch around 1.0. The algorithm makes use of two conjugate partial angle reconstruction images for motion estimation via non-rigid registration which is followed by a motion compensated reconstruction. Differently from other conventional approaches, no segmentation is adopted in motion estimation. This makes motion estimation of various fine lung structures possible. The aim of this study is to explore the performance of the proposed method in correcting the lung motion artifacts which arise even under routine CT scans with breath-hold. The artifacts are known to mimic various lung diseases, so it is of great interest to address the problem. For that purpose, a moving phantom experiment and clinical study (seven cases) were conducted. We selected the entropy and positivity as figure of merits to compare the reconstructed images before and after the motion correction. Results of both phantom and clinical studies showed a statistically significant improvement by the proposed method, namely up to 53.6% (p < 0.05) and up to 35.5% (p < 0.05) improvement by means of the positivity measure, respectively. Images of the proposed method show significantly reduced motion artifacts of various lung structures such as lung parenchyma, pulmonary vessels, and airways which are prominent in FBP images. Results of two exemplary cases also showed great potential of the proposed method in correcting motion artifacts of the aorta which is known to mimic aortic dissection. Compared to other approaches, the proposed method provides an excellent performance and a fully automatic workflow. In addition, it has a great potential to handle motions in wide range of organs such as lung structures and the aorta. We expect that this would pave a way toward innovations in chest and thorax CT imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Prospective motion correction of X-ray images for coronary interventions
    Shechter, G
    Shechter, B
    Resar, JR
    Beyar, R
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (04) : 441 - 450
  • [22] First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline
    邓彪
    杨群
    谢红兰
    杜国浩
    肖体乔
    中国物理C, 2011, (04) : 402 - 404
  • [23] First X-ray fluorescence CT experimental results at the SSRF X-ray imaging beamline
    Deng Biao
    Yang Qun
    Xie Hong-Lan
    Du Guo-Hao
    Xiao Ti-Qiao
    CHINESE PHYSICS C, 2011, 35 (04) : 402 - 404
  • [24] Tumor Motion Tracking in a KV Scattered X-Ray Imaging System for Lung Cancer Radiotherapy
    Zhong, Y.
    Chiu, T.
    Huang, Y.
    Shao, Y.
    Shen, C.
    Yang, K.
    Jia, X.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Motion correction for robot-based X-ray photon-counting CT at ultrahigh resolution
    Li, Mengzhou
    Bohacova, Jana
    Uher, Josef
    Cong, Wenxiang
    Rubinstein, Jay
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY XIV, 2022, 12242
  • [26] X-RAY CT AND NMR IMAGING OF ROCKS.
    Vinegar, H.J.
    1600, (38):
  • [27] Technology for small animal x-ray and CT imaging
    Boone, JM
    MEDICAL PHYSICS, 2005, 32 (06) : 2097 - 2097
  • [28] STEAM COREFLOODS WITH CONCURRENT X-RAY CT IMAGING
    CUTHIELL, D
    SEDGWICK, G
    KISSEL, G
    WOOLLEY, J
    JOURNAL OF CANADIAN PETROLEUM TECHNOLOGY, 1993, 32 (03): : 37 - 45
  • [29] Compton Scatter in X-Ray Fluorescence CT Imaging
    Bazalova, M.
    Kuang, Y.
    Pratx, G.
    Xing, L.
    MEDICAL PHYSICS, 2012, 39 (06) : 3986 - 3986
  • [30] A comparison of x-ray detectors for mouse CT imaging
    Goertzen, AL
    Nagarkar, V
    Street, RA
    Paulus, MJ
    Boone, JM
    Cherry, SR
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (23): : 5251 - 5265