Motion correction for routine X-ray lung CT imaging

被引:2
|
作者
Kim, Doil [1 ]
Choi, Jiyoung [1 ]
Lee, Duhgoon [1 ]
Kim, Hyesun [1 ]
Jung, Jiyoung [1 ]
Cho, Minkook [1 ]
Lee, Kyoung-Yong [1 ]
机构
[1] Samsung Elect Co Ltd, CT R&D Grp, Hlth & Med Equipment Business, Suwon, South Korea
关键词
D O I
10.1038/s41598-021-83403-w
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
A novel motion correction algorithm for X-ray lung CT imaging has been developed recently. It was designed to perform for routine chest or thorax CT scans without gating, namely axial or helical scans with pitch around 1.0. The algorithm makes use of two conjugate partial angle reconstruction images for motion estimation via non-rigid registration which is followed by a motion compensated reconstruction. Differently from other conventional approaches, no segmentation is adopted in motion estimation. This makes motion estimation of various fine lung structures possible. The aim of this study is to explore the performance of the proposed method in correcting the lung motion artifacts which arise even under routine CT scans with breath-hold. The artifacts are known to mimic various lung diseases, so it is of great interest to address the problem. For that purpose, a moving phantom experiment and clinical study (seven cases) were conducted. We selected the entropy and positivity as figure of merits to compare the reconstructed images before and after the motion correction. Results of both phantom and clinical studies showed a statistically significant improvement by the proposed method, namely up to 53.6% (p < 0.05) and up to 35.5% (p < 0.05) improvement by means of the positivity measure, respectively. Images of the proposed method show significantly reduced motion artifacts of various lung structures such as lung parenchyma, pulmonary vessels, and airways which are prominent in FBP images. Results of two exemplary cases also showed great potential of the proposed method in correcting motion artifacts of the aorta which is known to mimic aortic dissection. Compared to other approaches, the proposed method provides an excellent performance and a fully automatic workflow. In addition, it has a great potential to handle motions in wide range of organs such as lung structures and the aorta. We expect that this would pave a way toward innovations in chest and thorax CT imaging.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Motion correction for routine X-ray lung CT imaging
    Doil Kim
    Jiyoung Choi
    Duhgoon Lee
    Hyesun Kim
    Jiyoung Jung
    Minkook Cho
    Kyoung-Yong Lee
    Scientific Reports, 11
  • [2] Head motion correction based on filtered backprojection for x-ray CT imaging
    Jang, Seokhwan
    Kim, Seungeon
    Kim, Mina
    Ra, Jong Beom
    MEDICAL PHYSICS, 2018, 45 (02) : 589 - 604
  • [3] Streak Artifact Correction in X-ray CT Imaging
    Li B.-L.
    Mo Y.
    Zhang P.-Y.
    Li B.
    Zhang Y.-J.
    1600, Atomic Energy Press (51): : 2075 - 2078
  • [4] Correction for human head motion in helical x-ray CT
    Kim, J-H
    Sun, T.
    Alcheikh, A. R.
    Kuncic, Z.
    Nuyts, J.
    Fulton, R.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04): : 1416 - 1438
  • [5] X-ray scatter correction algorithm for cone beam CT imaging
    Ning, R
    Tang, XY
    Conover, D
    MEDICAL PHYSICS, 2004, 31 (05) : 1195 - 1202
  • [6] Cardiac motion correction based on partial angle reconstructed images in x-ray CT
    Kim, Seungeon
    Chang, Yongjin
    Ra, Jong Beom
    MEDICAL PHYSICS, 2015, 42 (05) : 2560 - 2571
  • [7] Motion Based X-Ray Imaging Modality
    Szigeti, Krisztian
    Mathe, Domokos
    Osvath, Szabolcs
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2014, 33 (10) : 2031 - 2038
  • [8] X-RAY AND LUNG FUNCTION IN THE ROUTINE ANALYTICAL DIAGNOSTICS OF LUNG EMPHYSEMA
    HOFFARTH, HP
    SCHLOSSER, S
    WIEBE, V
    ATEMWEGS-UND LUNGENKRANKHEITEN, 1984, 10 (08) : 414 - 420
  • [9] New trends in X-ray CT imaging
    Deych, Ruvin
    Dolazza, Enrico
    RADIATION DETECTORS FOR MEDICAL APPLICATIONS, 2006, : 15 - +
  • [10] Attenuation correction for small animal SPECT imaging using x-ray CT data
    Hwang, AB
    Hasegawa, BH
    MEDICAL PHYSICS, 2005, 32 (09) : 2799 - 2804