Evaluation of a Low-Cost Bubble CPAP System Designed for Resource-Limited Settings

被引:11
|
作者
Bennett, Desmond J. [1 ]
Carroll, Ryan W. [4 ]
Kacmarek, Robert M. [1 ,2 ,3 ]
机构
[1] Massachusetts Gen Hosp, Dept Resp Care, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA USA
[4] Massachusetts Gen Hosp, Dept Pediat Crit Care Med, Boston, MA 02114 USA
关键词
CPAP; bubbleCPAP; respiratory distress; low-resource settings; Uganda; neonate; POSITIVE AIRWAY PRESSURE; NONINVASIVE VENTILATION; RESPIRATORY-DISTRESS; LEAK COMPENSATION; LUNG MODEL; PREMATURE-INFANTS; PRETERM INFANTS; COUNTRIES; SUPPORT; CHILDREN;
D O I
10.4187/respcare.05762
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Respiratory compromise is a leading contributor to global neonatal death. CPAP is a method of treatment that helps maintain lung volume during expiration, promotes comfortable breathing, and improves oxygenation. Bubble CPAP is an effective alternative to standard CPAP. We sought to determine the reliability and functionality of a low-cost bubble CPAP device designed for low-resource settings. METHODS: The low-cost bubble CPAP device was compared to a commercially available bubble CPAP system. The devices were connected to a lung simulator that simulated neonates of 4 different weights with compromised respiratory mechanics (similar to 1, similar to 3, similar to 5, and similar to 10 kg). The devices' abilities to establish and maintain pressure and flow under normal conditions as well as under conditions of leak were compared. Multiple combinations of pressure levels (5, 8, and 10 cm H2O) and flow levels (3, 6, and 10 L/min) were tested. The endurance of both devices was also tested by running the systems continuously for 8 h and measuring the changes in pressure and flow. RESULTS: Both devices performed equivalently during the no-leak and leak trials. While our testing revealed individual differences that were statistically significant and clinically important (>10% difference) within specific CPAP and flow-level settings, no overall comparisons of CPAP or flow were both statistically significant and clinically important. Each device delivered pressures similar to the desired pressures, although the flows delivered by both machines were lower than the set flows in most trials. During the endurance trials, the low-cost device was marginally better at maintaining pressure, while the commercially available device was better at maintaining flow. CONCLUSIONS: The low-cost bubble CPAP device evaluated in this study is comparable to a bubble CPAP system used in developed settings. Extensive clinical trials, however, are necessary to confirm its effectiveness. (c) 2018 Daedalus Enterprises
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [31] Advancing HIV Vaccine Research With Low-Cost High-Performance Computing Infrastructure: An Alternative Approach for Resource-Limited Settings
    Mabvakure, Batsirai M.
    Rott, Raymond
    Dobrowsky, Leslie
    Van Heusden, Peter
    Morris, Lynn
    Scheepers, Cathrine
    Moore, Penny L.
    BIOINFORMATICS AND BIOLOGY INSIGHTS, 2019, 13
  • [32] Low-Cost Simulation Program for Resource-Limited Settings. Latin American VAST (Vital Anaesthesia Simulation Training) Experience
    Haylock-Loor, Carolina
    Duarte Giraldo, Juan C.
    Flores de Izquierdo, Sandra E.
    Leal Aquino, Sandra C.
    Mossenson, Adam
    Livingston, Patricia
    ANESTHESIA AND ANALGESIA, 2024, 139 (06):
  • [33] A Short Trauma Course for Physicians in a Resource-Limited Setting: Is Low-Cost Simulation Effective?
    Pringle, K.
    Mackey, J.
    Ruskis, J.
    Modi, P.
    Foggle, J.
    Levine, A. C.
    ANNALS OF EMERGENCY MEDICINE, 2013, 62 (04) : S100 - S100
  • [34] Low-cost portable EEG device for bridging the diagnostic gap in resource-limited areas
    Larsen, Sidsel Armand
    Klok, Louise
    Lehn-Schioler, William
    Gatej, Radu
    Beniczky, Sandor
    EPILEPTIC DISORDERS, 2024, 26 (05) : 694 - 700
  • [35] A short trauma course for physicians in a resource-limited setting: Is low-cost simulation effective?
    Pringle, K.
    Mackey, J. M.
    Modi, P.
    Janeway, H.
    Romero, T.
    Meynard, F.
    Perez, H.
    Herrera, R.
    Bendana, M.
    Labora, A.
    Ruskis, J.
    Foggle, J.
    Partridge, R.
    Levine, A. C.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (09): : 1796 - 1800
  • [36] Evaluation of Noncommercial Ultrasound Gels for Use in Resource-Limited Settings
    Vinograd, Alexandra M.
    Fasina, Abiola
    Dean, Anthony J.
    Shofer, Frances
    Panebianco, Nova L.
    Lewiss, Resa E.
    Gupta, Saurabh
    Rao, A. K. Raja
    Henwood, Patricia C.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (02) : 371 - 377
  • [37] Cost-Effective Diagnostic Checklists for Meningitis in Resource-Limited Settings
    Durski, Kara N.
    Kuntz, Karen M.
    Yasukawa, Kosuke
    Virnig, Beth A.
    Meya, David B.
    Boulware, David R.
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2013, 63 (03) : E101 - E108
  • [38] Advancing laparoscopy in resource-limited settings
    Djote, Surafel Mulatu
    Muhie, Daniel Ahmed
    Alemayehu, Getachew Desta
    BMC SURGERY, 2024, 24 (01)
  • [39] Transmission of Tuberculosis in Resource-Limited Settings
    Kompala, Tejaswi
    Shenoi, Sheela V.
    Friedland, Gerald
    CURRENT HIV/AIDS REPORTS, 2013, 10 (03) : 264 - 272
  • [40] Management of Fibroids in Resource-Limited Settings
    Nusair, Bassam
    Maaita, Maher
    Taso, Omar
    Almasaleha, Anas
    Abdelazim, Ibrahim A.
    Abu Faza, Mohannad
    CURRENT OBSTETRICS AND GYNECOLOGY REPORTS, 2018, 7 (02): : 92 - 96