Evaluation of a Low-Cost Bubble CPAP System Designed for Resource-Limited Settings

被引:11
|
作者
Bennett, Desmond J. [1 ]
Carroll, Ryan W. [4 ]
Kacmarek, Robert M. [1 ,2 ,3 ]
机构
[1] Massachusetts Gen Hosp, Dept Resp Care, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Anesthesia Crit Care & Pain Med, Boston, MA 02114 USA
[3] Harvard Med Sch, Boston, MA USA
[4] Massachusetts Gen Hosp, Dept Pediat Crit Care Med, Boston, MA 02114 USA
关键词
CPAP; bubbleCPAP; respiratory distress; low-resource settings; Uganda; neonate; POSITIVE AIRWAY PRESSURE; NONINVASIVE VENTILATION; RESPIRATORY-DISTRESS; LEAK COMPENSATION; LUNG MODEL; PREMATURE-INFANTS; PRETERM INFANTS; COUNTRIES; SUPPORT; CHILDREN;
D O I
10.4187/respcare.05762
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Respiratory compromise is a leading contributor to global neonatal death. CPAP is a method of treatment that helps maintain lung volume during expiration, promotes comfortable breathing, and improves oxygenation. Bubble CPAP is an effective alternative to standard CPAP. We sought to determine the reliability and functionality of a low-cost bubble CPAP device designed for low-resource settings. METHODS: The low-cost bubble CPAP device was compared to a commercially available bubble CPAP system. The devices were connected to a lung simulator that simulated neonates of 4 different weights with compromised respiratory mechanics (similar to 1, similar to 3, similar to 5, and similar to 10 kg). The devices' abilities to establish and maintain pressure and flow under normal conditions as well as under conditions of leak were compared. Multiple combinations of pressure levels (5, 8, and 10 cm H2O) and flow levels (3, 6, and 10 L/min) were tested. The endurance of both devices was also tested by running the systems continuously for 8 h and measuring the changes in pressure and flow. RESULTS: Both devices performed equivalently during the no-leak and leak trials. While our testing revealed individual differences that were statistically significant and clinically important (>10% difference) within specific CPAP and flow-level settings, no overall comparisons of CPAP or flow were both statistically significant and clinically important. Each device delivered pressures similar to the desired pressures, although the flows delivered by both machines were lower than the set flows in most trials. During the endurance trials, the low-cost device was marginally better at maintaining pressure, while the commercially available device was better at maintaining flow. CONCLUSIONS: The low-cost bubble CPAP device evaluated in this study is comparable to a bubble CPAP system used in developed settings. Extensive clinical trials, however, are necessary to confirm its effectiveness. (c) 2018 Daedalus Enterprises
引用
收藏
页码:395 / 403
页数:9
相关论文
共 50 条
  • [21] CPAP Protocol Reduces Intubation and Mortality of Pneumonia Patients in Resource-Limited Settings
    Pagnarith, Y.
    Chhomrath, S.
    Reynolds, J.
    Kumar, V.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2008, 12 : E243 - E243
  • [22] Can HIV reverse transcriptase activity assay be a low-cost alternative for viral load monitoring in resource-limited settings?
    Gupta, Soham
    Palchaudhuri, Riya
    Neogi, Ujjwal
    Srinivasa, Hiresave
    Ashorn, Per
    De Costa, Ayesha
    Kallander, Clas
    Shet, Anita
    BMJ OPEN, 2016, 6 (01):
  • [23] Melt-and-mold fabrication (MnM-Fab) of reconfigurable low-cost devices for use in resource-limited settings
    Li, Zhi
    Tevis, Ian D.
    Oyola-Reynoso, Stephanie
    Newcomb, Lucas B.
    Halbertsma-Black, Julian
    Bloch, Jean-Francis
    Thuo, Martin
    TALANTA, 2015, 145 : 20 - 28
  • [24] Headache in Resource-Limited Settings
    Yohannes W. Woldeamanuel
    Current Pain and Headache Reports, 2017, 21
  • [25] The cost effectiveness of antiretroviral treatment strategies in resource-limited settings
    Bishai, David
    Colchero, Arantxa
    Durack, David T.
    AIDS, 2007, 21 (10) : 1333 - 1340
  • [26] Resuscitation in resource-limited settings
    Ersdal, H. L.
    Singhal, N.
    SEMINARS IN FETAL & NEONATAL MEDICINE, 2013, 18 (06): : 373 - 378
  • [27] Cancer in Resource-Limited Settings
    Krown, Susan E.
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2011, 56 (04) : 297 - 299
  • [28] Headache in Resource-Limited Settings
    Woldeamanuel, Yohannes W.
    CURRENT PAIN AND HEADACHE REPORTS, 2017, 21 (12)
  • [29] Development and evaluation of a low-cost, portable, LED-based device for PDT treatment of early-stage oral cancer in resource-limited settings
    Liu, Hui
    Daly, Liam
    Rudd, Grant
    Khan, Amjad P.
    Mallidi, Srivalleesha
    Liu, Yiran
    Cuckov, Filip
    Hasan, Tayyaba
    Celli, Jonathan P.
    LASERS IN SURGERY AND MEDICINE, 2019, 51 (04) : 345 - 351
  • [30] Fine needle aspiration cytology in pediatric tumors: a low-cost, high-accuracy diagnostic tool for resource-limited settings
    Gupta, Parikshaa
    Bhardwaj, Subhash
    Wani, Farooq Ahmed
    Sayeed, Ubaidullah
    Banday, Altaf
    AMERICAN JOURNAL OF TRANSLATIONAL RESEARCH, 2023, 15 (11): : 6486 - 6494