Randomized Comparison of Nylon Versus Absorbing Polyglactin 910 for Fascial Closure in Caesarean Section

被引:8
|
作者
Kahkhaie, Kolsoum Rezaie [1 ]
Keikhaie, Khadije Rezaie [2 ]
Vahed, Aziz Shahreki [3 ]
Shirazi, Mahboobeh [4 ]
Amjadi, Nooshin [2 ]
机构
[1] Zabol Univ Med Sci ZBUMS, Med Plants Res Ctr, Zabol, Iran
[2] Zabol Univ Med Sci ZBUMS, Dept Perinatal, Zabol, Iran
[3] Zabol Univ Med Sci ZBUMS, Nursing & Midwifery Sch, Zabol, Iran
[4] Univ Tehran Med Sci, Maternal Fetal & Neonatal Res Ctr, Tehran, Iran
关键词
Surgery; Sutures; Caesarean Section; Polygalactin; 910; METAANALYSIS; DEHISCENCE;
D O I
10.5812/ircmj.12580
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Regardless of numerous advances in surgical techniques, selection of the best technique to sew up wounds and the best suture material are still controversial. Several postoperative complications, including wound infection, stitched wound, chronic incision pain, wound dehiscence and hernia stitches result from many factors such as used suture material. Objectives: The aim of the present study was to investigate the complications of pfannenstiel incision and nylon/polyglactin 910 sutures utilization in patients undergoing c-section cesarean. Patients and Methods: This clinical trial was conducted on 120 women who underwent caesarean section at Imam-Ali hospital in Zabol, Iran. In this study, patients were equally divided into two groups of 60 people (50% in nylon suture and 50% in polyglactin 910 sutures). Patients of the two groups were investigated by a gynecologist 24-48 hours after the operation, a week later and on the sixth month of surgery. Moreover, time of wound dehiscence and treatment duration, the level of sinus infection, chronic incision pain and incision hernia were studied. The results were analyzed by SPSS software. P <= 0.05 was considered as statistically significant. Results: One hundred and twenty patients undergoing a cesarean section at Imam-Ali hospital in Zabol were recruited into the study, 60 in the Nylon group and 60 in Polyglactin 910group. Our data demonstrated a statistically higher incidence of suture sinus and chronic incision pain in the nylon group (P < 0.05). No statistically significant difference in wound stitch and incision hernia was demonstrated between the suture groups. Conclusions: The results of our trial did not demonstrate a significant difference between absorbing polyglactin 910 (PDS) and nylon regarding incision hernia, wound infection and wound dehiscence. However, subjects sutured with PDS were less likely to experience chronic incision pain and wound stitch. Therefore, PDS appears to be the optimal choice for fascial closure after cesarean section.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Photographic assessment of postsurgical facial scars epidermally sutured with rapidly absorbable polyglactin 910 or nylon: A randomized clinical trial
    Moran, Benvon
    Humphrey, Shannon
    Seal, Alexander
    Berkowitz, Jonathan
    Zloty, David
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2020, 83 (05) : 1395 - 1399
  • [22] Comparison of the Incidence of Surgical Site Infection in Abdominal Wound Closure: Antibiotic-Coated Polyglactin 910 Suture Versus Polyglactin Suture With Local Infiltration of Antibiotic Along the Incision Line
    Singh, Chhavindar
    Pratap, Prakhar
    Singh, Rahul
    Pandey, Vinod K.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (08)
  • [23] Ex Vivo Comparison of 7 Polydioxanone, 2 Polyglactin 910 for Closure of Ventral Median Celiotomy in Horses
    Anderson, Stacy L.
    Bracamonte, Jose L.
    Hendrick, Steve
    Carmalt, James L.
    Wilson, David G.
    VETERINARY SURGERY, 2013, 42 (04) : 463 - 467
  • [24] Techniques for wound closure at caesarean section: a randomized controlled trial
    Rengerink, Katrien Oude
    Mol, Ben Willem
    Pajkrt, Eva
    de Graaf, Irene
    Wiersma, Irene
    Donker, Marielle
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2011, 204 : S267 - S267
  • [25] Techniques for wound closure at caesarean section: a randomized clinical trial
    de Graaf, I. M.
    Rengerink, K. Oude
    Wiersma, I. C.
    Donker, M. E.
    Mol, B. W.
    Pajkrt, E.
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2012, 165 (01) : 47 - 52
  • [26] DEXON PLUS VERSUS MAXON FASCIAL CLOSURE IN MORBID-OBESITY - A PROSPECTIVE RANDOMIZED COMPARISON
    DEITEL, M
    ALHINDAWI, R
    YAMEN, M
    TO, TB
    BURUL, CJ
    CANADIAN JOURNAL OF SURGERY, 1990, 33 (04) : 302 - 304
  • [27] Comparison of polyglactin-910 and polydioxanone for closure of the linea alba following caudal ventral midline laparotomy in sheep
    Rousseau, Marjolaine
    Anderson, David E.
    Rozell, Timothy G.
    Hand, Jacqelyn M.
    Faris, Brian R.
    CANADIAN VETERINARY JOURNAL-REVUE VETERINAIRE CANADIENNE, 2015, 56 (09): : 959 - 963
  • [28] Subcuticular skin closure at cesarean delivery with poliglecaprone-25 vs polyglactin-910: a randomized controlled trial
    Sharma, Chanderdeep
    Sharma, Shikha
    Soni, Anjali
    AMERICAN JOURNAL OF OBSTETRICS & GYNECOLOGY MFM, 2024, 6 (02)
  • [29] Improved outcomes of scar revision with the use of polydioxanone suture in comparison to polyglactin 910: A randomized controlled trial
    Gupta, Deepti
    Sharma, Upendra
    Chauhan, Shashank
    Sahu, Shamendra Anand
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2018, 71 (08): : 1159 - 1163