Randomized Comparison of Nylon Versus Absorbing Polyglactin 910 for Fascial Closure in Caesarean Section

被引:8
|
作者
Kahkhaie, Kolsoum Rezaie [1 ]
Keikhaie, Khadije Rezaie [2 ]
Vahed, Aziz Shahreki [3 ]
Shirazi, Mahboobeh [4 ]
Amjadi, Nooshin [2 ]
机构
[1] Zabol Univ Med Sci ZBUMS, Med Plants Res Ctr, Zabol, Iran
[2] Zabol Univ Med Sci ZBUMS, Dept Perinatal, Zabol, Iran
[3] Zabol Univ Med Sci ZBUMS, Nursing & Midwifery Sch, Zabol, Iran
[4] Univ Tehran Med Sci, Maternal Fetal & Neonatal Res Ctr, Tehran, Iran
关键词
Surgery; Sutures; Caesarean Section; Polygalactin; 910; METAANALYSIS; DEHISCENCE;
D O I
10.5812/ircmj.12580
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Regardless of numerous advances in surgical techniques, selection of the best technique to sew up wounds and the best suture material are still controversial. Several postoperative complications, including wound infection, stitched wound, chronic incision pain, wound dehiscence and hernia stitches result from many factors such as used suture material. Objectives: The aim of the present study was to investigate the complications of pfannenstiel incision and nylon/polyglactin 910 sutures utilization in patients undergoing c-section cesarean. Patients and Methods: This clinical trial was conducted on 120 women who underwent caesarean section at Imam-Ali hospital in Zabol, Iran. In this study, patients were equally divided into two groups of 60 people (50% in nylon suture and 50% in polyglactin 910 sutures). Patients of the two groups were investigated by a gynecologist 24-48 hours after the operation, a week later and on the sixth month of surgery. Moreover, time of wound dehiscence and treatment duration, the level of sinus infection, chronic incision pain and incision hernia were studied. The results were analyzed by SPSS software. P <= 0.05 was considered as statistically significant. Results: One hundred and twenty patients undergoing a cesarean section at Imam-Ali hospital in Zabol were recruited into the study, 60 in the Nylon group and 60 in Polyglactin 910group. Our data demonstrated a statistically higher incidence of suture sinus and chronic incision pain in the nylon group (P < 0.05). No statistically significant difference in wound stitch and incision hernia was demonstrated between the suture groups. Conclusions: The results of our trial did not demonstrate a significant difference between absorbing polyglactin 910 (PDS) and nylon regarding incision hernia, wound infection and wound dehiscence. However, subjects sutured with PDS were less likely to experience chronic incision pain and wound stitch. Therefore, PDS appears to be the optimal choice for fascial closure after cesarean section.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] COMPARISON OF POLYGLACTIN-910 AND NYLON IN SKIN CLOSURE
    GOULBOURNE, IA
    NIXON, SJ
    NAYLOR, AR
    VARMA, JS
    BRITISH JOURNAL OF SURGERY, 1988, 75 (06) : 586 - 586
  • [2] Skin closure at cesarean section, polypropylene versus polyglactin 910: a randomized controlled study
    Koroglu, Nadiye
    Yuksel, Ilkbal Temel
    Cetin, Berna Aslan
    Aytufan, Zubeyde
    Deniz, Necip
    Akca, Aysu
    Yildirim, Gonca Yetkin
    Yuksel, Aytac
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (06): : 1088 - 1092
  • [3] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair
    Dandolu, V
    Chatwani, A
    OBSTETRICS AND GYNECOLOGY, 2004, 104 (05): : 1104 - 1105
  • [4] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair
    Greenberg, JA
    Lieberman, E
    Cohen, AP
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (06): : 1308 - 1313
  • [5] Impact of chromic catgut versus polyglactin 910 versus fast-absorbing polyglactin 910 sutures for perineal repair: A randomized, controlled trial
    Leroux, Nathalie
    Bujold, Emmanuel
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2006, 194 (06) : 1585 - 1590
  • [6] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair - In reply
    Greenberg, JA
    Lieberman, E
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 104 (05): : 1105 - 1105
  • [7] Performance comparison of nylon and an absorbable suture material (polyglactin 910) in the closure of punch biopsy sites
    Gabel, EA
    Jimenez, GP
    Eaglstein, WH
    Kerdel, FA
    Falanga, V
    DERMATOLOGIC SURGERY, 2000, 26 (08) : 750 - 752
  • [8] Rapidly Absorbing Polyglactin 910 Versus Poliglecaprone 25 for Laceration Repair: A Randomized Controlled Trial
    Morrell, Lindsay Helene
    Clark, Stephanie Marie Glass
    Morrell, Christopher
    Carroll, Ashley Woodward
    OBSTETRICS AND GYNECOLOGY, 2019, 133 : 190S - 190S
  • [10] A Randomized trial of chromic catgut versus fast-absorbing polyglactin 910 for postpartum perineal repairs
    Greenberg, JA
    Lieberman, E
    Cohen, AP
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 29S - 29S