Impact of chromic catgut versus polyglactin 910 versus fast-absorbing polyglactin 910 sutures for perineal repair: A randomized, controlled trial

被引:14
|
作者
Leroux, Nathalie
Bujold, Emmanuel
机构
[1] Univ Montreal, Hop St Justine, Dept Obstet & Gynecol, Div Maternal Fetal Med, Montreal, PQ H3T 1C5, Canada
[2] Wayne State Univ, Dept Obstet & Gynecol, Detroit, MI USA
关键词
sutures; episiotomy; perineal pain;
D O I
10.1016/j.ajog.2006.01.011
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: The goal of our study was to compare the impact of 3 suture materials on perineal pain and on resumption of sexual intercourse. Study design: This randomized, controlled trial compared 3 types of suture materials (chromic catgut, polyglactin 910, fast-absorbing polyglactin 910) for second-degree perinea( laceration or uncomplicated episiotomy. Patients were enrolled in early labor and assigned randomly to 1 of the 3 suture materials. Pain was evaluated at 48 hours, 6 weeks, and 3 months. The study subjects were questioned about residual perinea( pain, resumption of sexual activity, and pain-free sexual intercourse. Logistic regression analyses were undertaken. Results: Of the 192 patients who were assigned randomly to groups, 66 patients had their periveal laceration repaired with chromic catgut; 60 patients had repair with polyglactin 910, and 66 patients had repair with fast-absorbing polyglactin 910. At 48 hours, there was no significant difference according to the pain measurement scores, but the median consumption of analgesics was significantly lower with fast-absorbing polyglactin 910 than with standard polyglactin 910. There was no difference in the resumption of sexual intercourse at 6 weeks after the delivery between chromic catgut (42%) compared-with standard polyglactin 910 group (56%; P =.23). However, it was more frequent for women in the fast-absorbing polyglactin 910 group (66%; P. =.02). After adjustment for confounding variables, perineal repair with fast-absorbing polyglactin 910 was associated with a higher rate of sexual intercourse (odds ratio, 2.55; 95% CI, 1.07-6.10) and a higher rate of pain-free sexual intercourse (odds ratio, 2.51; 95% Cl, 1.03-6.10) at 6 weeks after delivery. Conclusion: Fast-absorbing polyglactin 910 for perineal repair is associated with earlier resumption of sexual intercourse when compared with chromic catgut. (c) 2006 Mosby, Inc. All rights reserved.
引用
收藏
页码:1585 / 1590
页数:6
相关论文
共 33 条
  • [1] A Randomized trial of chromic catgut versus fast-absorbing polyglactin 910 for postpartum perineal repairs
    Greenberg, JA
    Lieberman, E
    Cohen, AP
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (04): : 29S - 29S
  • [2] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair
    Dandolu, V
    Chatwani, A
    OBSTETRICS AND GYNECOLOGY, 2004, 104 (05): : 1104 - 1105
  • [3] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair
    Greenberg, JA
    Lieberman, E
    Cohen, AP
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 103 (06): : 1308 - 1313
  • [4] Randomized comparison of chromic versus fast-absorbing polyglactin 910 for postpartum perineal repair - In reply
    Greenberg, JA
    Lieberman, E
    Ecker, JL
    OBSTETRICS AND GYNECOLOGY, 2004, 104 (05): : 1105 - 1105
  • [5] Rapidly Absorbing Polyglactin 910 Versus Poliglecaprone 25 for Laceration Repair: A Randomized Controlled Trial
    Morrell, Lindsay Helene
    Clark, Stephanie Marie Glass
    Morrell, Christopher
    Carroll, Ashley Woodward
    OBSTETRICS AND GYNECOLOGY, 2019, 133 : 190S - 190S
  • [6] Subcuticular catgut versus polyglactin 910 in scar formation in sheep
    Busic, Z
    Rudman, F
    Amic, E
    Stanec, Z
    Stipancic, I
    Busic, D
    VETERINARNI MEDICINA, 2003, 48 (03) : 79 - 82
  • [7] The Ipswich Childbirth Study: 2. A randomised comparison of polyglactin 910 with chromic catgut for postpartum perineal repair
    Mackrodt, C
    Gordon, B
    Fern, E
    Ayers, S
    Truesdale, A
    Grant, A
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1998, 105 (04): : 441 - 445
  • [8] Quantification of erythema associated with continuous nylon, polyglactin-910, and fast-absorbing gut sutures in facial surgery repair: A randomized prospective study
    MajdZadeh, Ali
    Lim, Catherine Elizabeth
    Zloty, David
    JOURNAL OF THE AMERICAN ACADEMY OF DERMATOLOGY, 2020, 83 (06) : AB21 - AB21
  • [9] Randomized Comparison of Nylon Versus Absorbing Polyglactin 910 for Fascial Closure in Caesarean Section
    Kahkhaie, Kolsoum Rezaie
    Keikhaie, Khadije Rezaie
    Vahed, Aziz Shahreki
    Shirazi, Mahboobeh
    Amjadi, Nooshin
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2014, 16 (04)
  • [10] Skin closure at cesarean section, polypropylene versus polyglactin 910: a randomized controlled study
    Koroglu, Nadiye
    Yuksel, Ilkbal Temel
    Cetin, Berna Aslan
    Aytufan, Zubeyde
    Deniz, Necip
    Akca, Aysu
    Yildirim, Gonca Yetkin
    Yuksel, Aytac
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2022, 35 (06): : 1088 - 1092