Optimization of solid tank design for fan-beam optical CT based 3D radiation dosimetry

被引:5
|
作者
Ogilvy, A. [1 ]
Collins, S. [1 ]
Tuokko, T. [1 ]
Hilts, M. [1 ,2 ]
Deardon, R. [3 ,4 ]
Hare, W. [5 ]
Jirasek, A. [1 ]
机构
[1] Univ British Columbia, Dept Phys, Okanagan Campus, Kelowna, BC V1V 1V7, Canada
[2] BC Canc Kelowna, Med Phys, Kelowna, BC V1Y 5L3, Canada
[3] Univ Calgary, Dept Math & Stat, Calgary, AB T2N 1N4, Canada
[4] Univ Calgary, Dept Prod Anim Hlth, Calgary, AB T2N 1N4, Canada
[5] Univ British Columbia, Dept Math, Okanagan Campus, Kelowna, BC V1V 1V7, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 24期
关键词
gel dosimetry; optical computed tomography; radiation dosimetry; gel dosimeter; optical CT; image reconstruction; ray tracing; GEL DOSIMETERS; SCANNER;
D O I
10.1088/1361-6560/abbf98
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical computed tomography (CT) is one of the leading modalities for imaging gel dosimeters for 3D radiation dosimetry. There exist multiple scanner designs that have showcased excellent 3D dose verification capabilities of optical CT gel dosimetry. However, due to multiple experimental and reconstruction based factors there is currently no single scanner that has become a preferred standard. A significant challenge with setup and maintenance can be attributed to maintaining a large refractive index bath (1-15 l). In this work, a prototype solid 'tank' optical CT scanner is proposed that minimizes the volume of refractive index bath to between 10 and 35 ml. A ray-path simulator was created to optimize the design such that the solid tank geometry maximizes light collection across the detector array, maximizes the volume of the dosimeter scanned, and maximizes the collected signal dynamic range. An objective function was created to score possible geometries, and was optimized to find a local maximum geometry score from a set of possible design parameters. The design parameters optimized include the block length x(bl), bore position x(bc), fan-laser position x(lp), lens block face semi-major axis length x(ma), and the lens block face eccentricity x(be). For the proposed design it was found that each of these parameters can have a significant effect on the signal collection efficacy within the scanner. Simulations scores are specific to the attenuation characteristics and refractive index of a simulated dosimeter. It was found that for a FlexyDos3D dosimeter, the ideal values for each of the five variables were: x(bl) = 314 mm, x(bc) = 6.5 mm, x(lp) = 50 mm, x(ma) = 66 mm, and x(be) = 0. In addition, a ClearView((TM)) dosimeter was found to have ideal values at: x(bl) = 204 mm, x(bc) = 13 mm, x(lp) = 58 mm, x(ma) = 69 mm, and x(be) = 0. The ray simulator can also be used for further design and testing of new, unique and purpose-built optical CT geometries.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Commissioning of a solid tank design for fan-beam optical CT based 3D radiation dosimetry
    Ogilvy, A.
    Collins, S.
    Hilts, M.
    Hare, W.
    Jirasek, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (17):
  • [2] A prototype fan-beam optical CT scanner for 3D dosimetry
    Campbell, Warren G.
    Rudko, D. A.
    Braam, Nicolas A.
    Wells, Derek M.
    Jirasek, Andrew
    MEDICAL PHYSICS, 2013, 40 (06)
  • [3] Simulated design optimization of a prototype solid tank optical CT scanner for 3D radiation dosimetry
    Ogilvy, A.
    Collins, S.
    Hare, W.
    Hilts, M.
    Tuokko, T.
    Deardon, R.
    Jirasek, A.
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [4] Imaging Protocol Investigations with a Fan-Beam Optical CT Scanner for 3D Dosimetry
    Campbell, W.
    Jirasek, A.
    Wells, D.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Fast 3D multiple fan-beam CT systems
    Kohlbrenner, A
    Hämmerle, S
    Laib, A
    Koller, B
    Rüegsegger, P
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 44 - 54
  • [6] Configuration Optimization of Optical Tomography Based on Fan-Beam Lasers
    Li, Huajun
    Liu, Guangyu
    Yu, Shanen
    Sun, Chuanshuo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
  • [7] 3D Temperature Distribution Measurement Based on Fan-Beam Projection Data by Using Ultrasonic CT
    Zhu, Ning
    Su, Zhou
    Jiang, Yong
    INFORMATION-AN INTERNATIONAL INTERDISCIPLINARY JOURNAL, 2010, 13 (3B): : 947 - 951
  • [8] Cone beam optical CT scanner for 3D dosimetry
    Miller, J
    Adamovics, J
    Dietrich, J
    MEDICAL PHYSICS, 2005, 32 (06) : 2138 - 2138
  • [9] A 3D microtomographic system with stacked fan-beam geometry
    Kohlbrenner, A
    Hämmerle, S
    Laib, A
    Rüegsegger, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 443 (2-3): : 531 - 539
  • [10] Optical CT scanner for in-air readout of gels for external radiation beam 3D dosimetry
    Ramm, Daniel
    Rutten, Thomas P.
    Shepherd, Justin
    Bezak, Eva
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (12): : 3853 - 3868