Optimization of solid tank design for fan-beam optical CT based 3D radiation dosimetry

被引:5
|
作者
Ogilvy, A. [1 ]
Collins, S. [1 ]
Tuokko, T. [1 ]
Hilts, M. [1 ,2 ]
Deardon, R. [3 ,4 ]
Hare, W. [5 ]
Jirasek, A. [1 ]
机构
[1] Univ British Columbia, Dept Phys, Okanagan Campus, Kelowna, BC V1V 1V7, Canada
[2] BC Canc Kelowna, Med Phys, Kelowna, BC V1Y 5L3, Canada
[3] Univ Calgary, Dept Math & Stat, Calgary, AB T2N 1N4, Canada
[4] Univ Calgary, Dept Prod Anim Hlth, Calgary, AB T2N 1N4, Canada
[5] Univ British Columbia, Dept Math, Okanagan Campus, Kelowna, BC V1V 1V7, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2020年 / 65卷 / 24期
关键词
gel dosimetry; optical computed tomography; radiation dosimetry; gel dosimeter; optical CT; image reconstruction; ray tracing; GEL DOSIMETERS; SCANNER;
D O I
10.1088/1361-6560/abbf98
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Optical computed tomography (CT) is one of the leading modalities for imaging gel dosimeters for 3D radiation dosimetry. There exist multiple scanner designs that have showcased excellent 3D dose verification capabilities of optical CT gel dosimetry. However, due to multiple experimental and reconstruction based factors there is currently no single scanner that has become a preferred standard. A significant challenge with setup and maintenance can be attributed to maintaining a large refractive index bath (1-15 l). In this work, a prototype solid 'tank' optical CT scanner is proposed that minimizes the volume of refractive index bath to between 10 and 35 ml. A ray-path simulator was created to optimize the design such that the solid tank geometry maximizes light collection across the detector array, maximizes the volume of the dosimeter scanned, and maximizes the collected signal dynamic range. An objective function was created to score possible geometries, and was optimized to find a local maximum geometry score from a set of possible design parameters. The design parameters optimized include the block length x(bl), bore position x(bc), fan-laser position x(lp), lens block face semi-major axis length x(ma), and the lens block face eccentricity x(be). For the proposed design it was found that each of these parameters can have a significant effect on the signal collection efficacy within the scanner. Simulations scores are specific to the attenuation characteristics and refractive index of a simulated dosimeter. It was found that for a FlexyDos3D dosimeter, the ideal values for each of the five variables were: x(bl) = 314 mm, x(bc) = 6.5 mm, x(lp) = 50 mm, x(ma) = 66 mm, and x(be) = 0. In addition, a ClearView((TM)) dosimeter was found to have ideal values at: x(bl) = 204 mm, x(bc) = 13 mm, x(lp) = 58 mm, x(ma) = 69 mm, and x(be) = 0. The ray simulator can also be used for further design and testing of new, unique and purpose-built optical CT geometries.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] 3D solid robot animation design based on ADAMS
    Baojian Yang
    Yongning Deng
    Xia Yue
    Kenneth Tze Kin Teo
    International Journal of System Assurance Engineering and Management, 2023, 14 : 578 - 590
  • [42] 3D Dosimetry based on a new optical approach for dosimetry gels: Use of the polarisation ratio of the scattering light
    Bleuse, O.
    Gschwind, R.
    Bailly, Y.
    Laurent, K.
    Bartova, H.
    Pilarova, K.
    Spevacek, V.
    Makovicka, L.
    9TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, 2017, 847
  • [43] 3D solid robot animation design based on ADAMS
    Yang, Baojian
    Deng, Yongning
    Yue, Xia
    Teo, Kenneth Tze Kin
    INTERNATIONAL JOURNAL OF SYSTEM ASSURANCE ENGINEERING AND MANAGEMENT, 2023, 14 (02) : 578 - 590
  • [44] 3D Fan-Beam Model Implimentation in a Hybrid Digital-Breast-Tomosynthesis Microwave Radar Imaging Breast Cancer Detection Algorithm
    Tivnan, Matthew
    Morgenthaler, Ann
    Rappaport, Carey M.
    2015 IEEE INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2015, : 532 - 533
  • [45] A study of geometrical and reconstruction artifacts in 3D gel-dosimetry utilizing optical-CT
    Oldham, M
    Kim, L
    MEDICAL PHYSICS, 2003, 30 (06) : 1426 - 1426
  • [46] Investigations into the feasibility of optical-CT 3D dosimetry with minimal use of refractively matched fluids
    Chisholm, Kelsey
    Miles, Devin
    Rankine, Leith
    Oldham, Mark
    MEDICAL PHYSICS, 2015, 42 (05) : 2607 - 2614
  • [47] 3D Dosimetry with a Novel Optical CT Scanner Using Fiber Optic Taper for Collimated Images
    Wuu, C.
    Wang, Y.
    Lemus, O. M. Dona
    Qian, X.
    Adamovics, J.
    Xu, A.
    MEDICAL PHYSICS, 2020, 47 (06) : E444 - E444
  • [48] An Investigation of a Low-Cost 'dry' Optical-CT Scanning System for 3D Dosimetry
    Bache, S.
    Malcolm, J.
    Adamovics, J.
    Oldham, M.
    MEDICAL PHYSICS, 2014, 41 (06) : 194 - 194
  • [49] How effective can optical-CT 3D dosimetry be without refractive fluid matching?
    Rankine, L.
    Oldham
    7TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY (IC3DDOSE), 2013, 444
  • [50] Aerodynamic optimization design of centrifugal fan blades based on 3-D inverse design method
    Yang, Wei
    Wang, Fujun
    Wang, Hong
    Yang, W. (wyang@cau.edu.cn), 1600, Chinese Society of Agricultural Machinery (43): : 105 - 109