Micro gas turbine cogeneration system with latent heat storage at the University: Part II: Part load and thermal priority mode

被引:12
|
作者
Kurata, Osamu [1 ]
Iki, Norihiko [1 ]
Matsunuma, Takayuki [1 ]
Maeda, Tetsuhiko [2 ]
Hirano, Satoshi [3 ]
Kadoguchi, Katsuhiko [4 ]
Takeuchi, Hiromi [4 ]
Yoshida, Hiro [5 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Turbomachinery Grp, Tsukuba, Ibaraki 3058564, Japan
[2] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Socioecon & Policy Study Grp, Tsukuba, Ibaraki 3058564, Japan
[3] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Thermal & Fluid Syst Grp, Tsukuba, Ibaraki 3058569, Japan
[4] Natl Inst Adv Ind Sci & Technol, Energy Technol Res Inst, Tsukuba, Ibaraki 305, Japan
[5] Kanagawa Inst Technol, Dept Vehicle Syst Engn, Atsugi, Kanagawa 2430292, Japan
关键词
Cogeneration system; Micro gas turbine; Latent heat storage; Phase-change material; University; Energy flow; Part-load operation; Thermal priority mode; Programmable logic controller; PERFORMANCE ANALYSIS; POWER; MICROTURBINE; OPERATION;
D O I
10.1016/j.applthermaleng.2013.12.050
中图分类号
O414.1 [热力学];
学科分类号
摘要
A good cogeneration system should have high efficiency and good coordination. A micro gas turbine cogeneration system with latent heat storage was demonstrated at the University. Since there had been no cogeneration system with the latent heat storage under service condition, this system was the first demonstration and its characteristic was very important. The proper use of the latent heat storage system will save energy economically, store high energy density, reduce exhaust emissions, and save operational costs. A heat exchanger and an economizer were located in parallel downstream of a bypass dumper for exhaust gas. The latent heat storage tank was located downstream of the economizer. The bypass dumper released exhaust gas when the boiler water in the heat exchanger exceeded 90 C. It is very important to use the heat supply of hot water as much as possible. At the University, the winter term heat demand from 6 pm to 7 pm was somewhat less than that from 8 am to 6 pm in 2010. We conducted a part-load operation from 6 pm to 7 pm to observe how it would respond to the heat demand. The heat supply from the cogeneration system during this time period was controllable with the heat storage. The heat supply from the system at the lowest power setting was larger than the heat demand, and thus was uncontrollable without heat storage. In Part I [1], a fixed operating schedule of the system was planned and demonstrated at the University. Total 407 charge/discharge cycles of the latent heat storage were repeated. The energy flow test of the system shows the importance of heat release source and total system design. In Part III [2], a temperature control schedule of the system was demonstrated in winter morning using a new programmable logic controller (PLC). If the more larger latent heat storage system will be developed in the future, it will be expected greatly that the temperature of the classrooms are kept more comfortable with less energy consumptions and less CO2 emission. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:246 / 254
页数:9
相关论文
共 50 条
  • [21] Design and part-load performance of a hybrid system based on a solid oxide fuel cell reactor and a micro gas turbine
    Costamagna, P
    Magistri, L
    Massardo, AF
    JOURNAL OF POWER SOURCES, 2001, 96 (02) : 352 - 368
  • [22] Performance analysis for the part-load operation of a solid oxide fuel cell-micro gas turbine hybrid system
    Komatsu, Y.
    Kimijima, S.
    Szmyd, J. S.
    ENERGY, 2010, 35 (02) : 982 - 988
  • [23] Experimental investigation of saturated fogging and overspray influence on part-load micro gas turbine performance
    Barakat, Elsayed
    Jin, Tai
    Tong, Xiaokang
    Ma, Chengbiao
    Wang, Gaofeng
    APPLIED THERMAL ENGINEERING, 2023, 219
  • [24] Analysis of design and part load performance of micro gas turbine/organic Rankine cycle combined systems
    Lee, Joon Hee
    Kim, Tong Seop
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2006, 20 (09) : 1502 - 1513
  • [25] Analysis of design and part load performance of micro gas turbine/organic Rankine cycle combined systems
    Joon Hee Lee
    Tong Seop Kim
    Journal of Mechanical Science and Technology, 2006, 20 : 1502 - 1513
  • [26] Thermo-economic analysis of an intercooled, reheat and recuperated gas turbine for cogeneration applications - Part I: Base load operation
    Bhargava, R
    Bianchi, M
    di Montenegro, GN
    Peretto, A
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2002, 124 (01): : 147 - 154
  • [27] Part-load Performance Characteristics of a Lean Burn Catalytic Combustion Gas Turbine System
    Juan Yin
    Ming Li
    Jun-qiang Zhu
    Journal of Thermal Science, 2013, 22 (02) : 159 - 167
  • [28] Part-load Performance Characteristics of a Lean Burn Catalytic Combustion Gas Turbine System
    Yin, Juan
    Li, Ming
    Zhu, Jun-qiang
    JOURNAL OF THERMAL SCIENCE, 2013, 22 (02) : 159 - 167
  • [29] Heat transfer of latent thermal energy storage capsules arranged in alignment with the fluid flow (part II. Analysis of solidification process)
    Hirata, Tetsuo
    Ueda, Hideki
    Fujiwara, Masanori
    Heat Transfer - Japanese Research, 1988, 17 (04): : 58 - 70
  • [30] Performance evaluation of micro gas turbine-solid oxide fuel cell hybrid system under part-load conditions
    Kimijima, Shinji
    Kasagi, Nobuhide
    Nippon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2004, 70 (692): : 1020 - 1027